Flow Range: 20 (2~16 l/min), Thread: Rc, Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: Rc, Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 20 (2~16 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Model: 33, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: A (C37, Seals: FKM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)

Model: 32, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, FLOW CONTROL, SVD, 224 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, FLOW CONTROL, SVD, 224 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, CLEAN, FLOW CONTROL, SVD, 124 lb

Function: 2 (2 Position Double), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in

Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal

Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal

Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in

Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in Standard