1 V7 LEFS 32 200 R H B B 3 M2 S r Motor type e Motor mounting position w Size q Accuracy Nil Basic type H High precision type 25 32 40 Nil In-line R Right side parallel L Left side parallel Symbol Type Output [W] Size Compatible driver V6 AC servo motor (Absolute encoder) 100 25 LECYM2-V5/LECYU2-V5 V7 200 32 LECYM2-V7/LECYU2-V7 V8 400 40 LECYM2-V8/LECYU2-V8 u Motor option t Lead [mm] i Cable
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
Tank model VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 394 Rc 3/8 VBAT20 VBAT20S 305 206 674 180 200 100 400 Rc 1/2 430 Rc 1/2 444 Rc 3/8 VBAT38 VBAT38S 355 256 824 205 250 150 500 Rc 3/4 480 Rc 1/2 14-9-9
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.
Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Electrical entry G C T TL Grommet Conduit Conduit terminal Conduit terminal with indicator light Clip part no. Note) Indicate the valve model no. as a label will be attached to the clip.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 1 8 1 4 ZFA200 L1 1 Number of manifold stations Model Symbol 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10 200 212 300 312 38 50 48 60 ZFA100 L2 L1 L2 ZFA200 13-10-3
XRAY-1250-100 XRAY-1250-100-POB XRAY-1250-200 XRAY-1250-200-POB Tandem XRAY1250-200 x-KIT-1250-100-COV XRAY-1250-100 x-KIT-1250-200-COV XRAY-1250-200 To Mount 6.5mm Prox. X-KIT-1250.I2MM To Mount 12mm Prox. X-KIT-1250-t8MM To Mount 1Smm Prox. The right to chnge designs and specifications without trolice is rcserved. All dat!
Bore Size: 80mm, Port Type: TF (G), Stroke: 25mm, Lock Position: R (Front Lock), Manual Override: L (Locking), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Bore Size: 32mm, Port Type: N (NPT), Stroke: 25mm, Lock Position: R (Front Lock), Manual Override: L (Locking), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 125mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: L (Locking), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC
Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: R (Front Lock), Release of Manual: L (Locking), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 850, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port