C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 100 VAC (50/60 Hz)4.2 A10 A180/200 W 50/60 Hz220 W0.01 ?
C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 100 VAC (50/60 Hz)4.2 A10 A180/200 W 50/60 Hz220 W0.01 ?
The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.55, Port size: main valve Rc(PT) 1/8, pilot valve (EXH) M5x0.8, VALVE,MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT
The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size: main valve Rc(PT) 1/8, pilot valve (EXH) M5x0.8, VALVE,MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT
Please contact us for the latest version.sales@ocaire.com, GP-400 GRIPPER W/DUAL SINK, ACTUATOR, GRIPPER, 21, GRIPPER NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, GPL-400 GRIPPER W/DUAL SINK, ACTUATOR, GRIPPER, 21, GRIPPER NO SIZE RATING, .00000 lb
The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.55, Port size: main valve Rc(PT) 1/8, pilot valve (EXH) M5x0.8, VALVE,MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT
The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.55, Port size: main valve Rc(PT) 1/8, pilot valve (EXH) M5x0.8, VALVE, MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT
Please contact us for the latest version.sales@ocaire.com, VALVE, MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT 1/4, .47586 lb
The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.55, Port size: main valve Rc(PT) 1/8, pilot valve (EXH) M5x0.8, VALVE,MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT
Referential tightening torque: 2.2 Nm 400 Series AF10 to 60 Replacement Procedure of Element 2 Procedure Tools Check item Process Applicable model Disassembly 1) Remove the bowl assembly. Push the bowl assembly lock button. Lifting the bowl assembly, rotate the assembly 45 degree (right or left) to pull out the assembly. Actuators Modular F.R.L.
moment around the Z1 axis of A part of attachment kgm2 Distance between Z and Z1 axis mm IZ1 Inertia moment around the Z2 axis of B part of attachment kgm2 Distance between Z and Z2 axis mm IZ2 Allowable Range of Moment of Inertia of Attachment MHY2-10D MHW2-20D MHW2-50D 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 1.0 4 400
and Z1 axis mm Inertia moment around the Z1 axis of A part of attachment kgm2 IZ1 MHL Distance between Z and Z2 axis mm Inertia moment around the Z2 axis of B part of attachment kgm2 IZ2 MHR Allowable Range of Inertia Moment of Attachment MHY2-10D MHW2-20D MHW2-50D MHK 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 MHS 1.0 4 400
N) 50 CX 0.2 MPa 20 Point of application L 0.3 MPa 40 CY 0.2 MPa 30 Lateral load F MQQ M 10 20 RHC 10 MK(2) RS Q G 80 70 30 40 50 60 30 60 70 50 40 20 Point of application L (mm) Point of application L (mm) RS H A RZQ MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 MI W S 200 320 0.7 MPa 500 CEP1 0.7 MPa 280 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.7 MPa 0.6 MPa 0.6 MPa 160 CE1 0.5 MPa 240 0.5 MPa 400
Arm Load A CRB2 Displacement CRB1 MSU MSZ10A MSZ20A CRJ CRA1 300 CRQ2 MSQ MSZB10A (Basic type) 400 MSZ MSZ MSZA20A (Basic type) Displacement m Displacement m 250 CRQ2X MSQX MRQ 350 200 40 190 40 30 30 MSZA10A (High precision type) MSZA20A (High precision type) 20 20 10 10 50 40 30 20 10 0 30 25 20 15 10 5 0 Load N Load N MSZ50A MSZ30A 350 300 300 250 250 MSZB30A (Basic type) MSZB50A (Basic
area (mm2) Operating pressure (MPa) Rod size (mm) Bore size (mm) Operating direction -XC22 Fluororubber seal 0.3 0.5 0.7 19 14 8 OUT 28 6 3 14 10 6 IN 21 55 39 23 OUT 78 10 4 46 33 19 IN 66 141 101 60 OUT 201 16 6 121 86 51 IN 172 220 157 94 OUT 314 20 8 185 132 79 IN 264 Weight (g) Stroke (mm) Model 5 10 15 20 25 30 40 50 60 MXH6 MXH10 MXH16 MXH20 61 104 194 352 66 112 204 369 75 125 222 400
freezing) Ambient and fluid temperature With auto switch: 10 to +60C (No freezing) Integrated clevis style 0.5 l/min (ANR) or less Allowable leakage Non-lube Lubrication JIS class 2 Thread tolerance JIS symbol +1.4 0 Stroke tolerance Rubber bumper Cushion Double acting/Single rod 1 8 1 4 Piping (Screw-in) Rc(PT) Rc(PT) Standard Stroke Long stroke (2) (mm) Bore size (mm) Standard stroke (mm) 400
(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic
Therefore, even if the conditions given above are not exceeded, the use of a shock absorber is recommended. 5 0 100 200 300 400 500 Speed (mm/s) Static Movable Weight When Stopped When the CXT Series cylinder is used for moving the workpiece receptacle, such as in a stamping or press-fitting process, a vertical load will be applied to the top surface of the stopped slide block (refer to the
Driver Energization type Divisions per rotation Full step 200 LC6D-220ADHalf step 400 Full step 500 LC6D-507ADHalf step 1000 Dimensions 100 97 52 42 Operation window 35 38 96 35 Label DIN rail holding plate Connectors (included) [Manufacturer: Molex Japan, Co., Ltd.] Quantity Description Part no.