Failure to do so may cause equipment failure or malfunction. 9. Mount the Fieldbus system in a location where there is no excessive vibration or shock. Failure to do so may cause equipment failure or malfunction. 10. Do not use in places where there are cyclic temperature changes.
The forward/reverse torque limit is set to 100% (3 times the motor rated torque) as default. 9. Keep the flatness of mounting surface 0.1 mm or less. This value is the maximum torque (the limit value) in the Position control mode, Speed control mode or Positioning mode.
10 11 12 13 14 Meter-in Black zinc chromate plated HNBR NBR NBR NBR NBR U seal Cassette Seal O-ring O-ring O-ring O-ring Spacer Gasket 9 10 11 12 13 14 15 16 17 HNBR NBR NBR NBR NBR NBR NBR, Stainless steel Note 1) Only AS221F-U01 and AS321F-U02 are electroless nickel plated.
Note 2) 52-SY9000 has no bracket. 5 7 9 52-SY5000 52-SY7000 52-SY9000 Thread type Type of actuation Nil F N T Rc G NPT NPTF 2-position single 2-position double 3-position closed centre 3-position exhaust centre 3-position pressure centre 1 2 3 4 5 A, B port size (Body ported type) Piping type Port size Applicable series Symbol 01 C4 C6 C8 N3 N7 N9 02 C8 C10 N9 N11 02 03 C8 C10 C12 N9 N11
How to Order ALD 20 B 9 00 S1 Float switch Style Nil None 1b (without oil ON) ALD ALDU D.P . Lube (Single unit) D.P .
Failure to observe this precaution could damage the filter element. 1.10-3 Regulator with Mist Separator AMR3000 to 6000 Dimensions AMR3000 AMR4000, 5000, 6000 N Bracket mounting dimension With auto drain Model Port size A B C D E F G H J K L M U (Body) V (Adapter) P 50 35 45 46.5 R 78 97 98 115 S 8 7 10 15 T 9 9 11 11 B 260 298 366 432 L 178 211 277 321 1 4, 3 8 1 4, 3 8 AMR3000 AMR4000
Select compatible materials of construction for the gas Vacuum to 125 psig (0.9 MPa) 200 psig (1.4 MPa) 375 pisg (2.7 MPa) -10 to 71C (No freezing) 0.29 0.5 Inboard leakage Outboard leakage 2 x 10-11 Pam3/s 2 x 10-10 Pam3/s 1) 4 x 10-9 Pam3/s 1) Ra 10in. (0.25 m) Face seal, Tube weld 60 to 110 psig (0.4 to 0.76 MPa) M5 x 0.8 Top Bottom mount 0.06 in3 (1.07 cm3) 0.24 kg 2) Leak rate Across
How to Order Internal pilot operated relieving type regulator AR 25 4 BG 02 Semi-standard Nil Flow direction: Right to left None (Standard) Regulator R Body size Port size Accessory 4 6 8 9 1 2 1 Symbol 1 Description Applicable model 02 03 04 06 10 12 14 20 1 4 Nil 2 1 8 3 B With bracket AR4 5 to 6 5 AR 25 AR 35 2 1 2 3 4 Gauge G46-10-02 G46-2-02 G Regulating pressure range 1 G46-P10-02-X30
A (2) Model T D1 H1 L4 (1) Applicable tubing O.D. d (g) Weight H2 D2 L1 L2 L3 M AS121F-M5-06W2 AS221F-01-06W2 AS221F-01-08W2 AS221F-01-10W2 AS221F-02-06W2 AS221F-02-08W2 AS221F-02-10W2 AS321F-02-06W2 AS321F-02-08W2 AS321F-02-10W2 AS321F-02-12W2 AS321F-03-06W2 AS321F-03-08W2 AS321F-03-10W2 AS321F-03-12W2 AS421F-04-10W2 AS421F-04-12W2 11.6 6 9 13.5 22.9 11.7 28.8 26 25.2 22.4 18.1 8 6 9.6 M5
Description Material Note Body A Body B Needle Needle guide Seat ring 1 2 3 4 5 Chromate plated Electroless nickel plated Electroless nickel plated Zinc alloy Brass Brass Brass Brass (1) (2) Meter-out Meter-in Zinc chromate plated Note 4) Lock nut 6 Steel (3) Black zinc chromate plated Handle Bushing Cassette U-packing Seal O-ring O-ring O-ring O-ring Gasket 7 8 9 10 11 12 13 14 15 16 Brass
JIS Symbol 15-9-19 2 Series AS How to Order 2 2 1 U02 06 K AS 1F Nil Option Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard None Hexagonal lock nut Electroless nickel plated K N If more than one option is required, write option part numbers in the order of K, N. Applicable tubing O.D.
Do not mount the product in locations where it is exposed to radiant heat. 9. Take appropriate measures against the lightning surge on the equipment side as the auto switches do not have any lightning surge resistance specified in the CE marking. Caution 1.
When using the sealant, other than the PTFE, it will be difficult to fully remove the sealant and this could cause malfunction or failure of the product. 9. After installation, perform a leak test. Perform a leak test, such as helium leak test, pressure decay test, bubble leak test, etc., depending on the application.
When using the sealant, other than the PTFE, it will be difficult to fully remove the sealant and this could cause malfunction or failure of the product. 9. After installation, perform a leak test. Perform a leak test, such as helium leak test, pressure decay test, bubble leak test, etc., depending on the application.
For Series CUX10, up to 0.1 Nl/min (ANR) of internal leakage is anticipated due to cylinder structure. 20Data 10-3-9 9 The external dimensions and the related things about auto switches are the same as standard type, double acting, single rod. For Series CQS, CDQS, refer to Best Pneumatics Vol. 7.
. * Please contact SMC for NPN switches. 2 CKZP Series Dimensions CKZP57L-m Rod extended 11.4 50 95 + Stroke 40 + Stroke 0.05 24.8 40 0.1 25 View A-A 50 100 (119.3) 11 0.1 11 0.1 30 0.03 4 surfaces 2 x 9 4 surfaces 2 x 6 F7 11 0.1 11 0.1 40 0.05 45 10 15 Coil scraper 68.5 55 127 + Stroke 45 0.03 95 9.5 26.5 A A 11 30 M12 connector (4 pin) 109 Protective plate 132.5 2 x 8 F7 depth 16 90 9.5
L: Aluminum, S: Stainless steel 570 A Process Valve: 2 Port Valve For Flow Control VNB Series Port size: 6A, 8A, 10A Applicable cable O.D. 6 to 8 (D.T) Standard Pg.9 (D.T) (Conduit terminal: T, DIN terminal: D) 2 x (Back side 10 (P2) ) Pilot port 12(P1) Manual override (Non-locking push type) 8 1 106.5 (Grommet terminal: E) 106.7 (Grommet: G) 63 (Air operated) 127 Main port 1(A) (Back side
Surge voltage suppressor (for D YS, D YZ) 2 locations 70 52 Light (for D YZ) 24.5 18 25.5 Bracket (Option) Pg7 18 83 Breathing hole (6.2) 48.6 42.2 90.4 41.9 Max.10 39.6 Manual override part 19.9 IN OUT OUT 2 1 IN EXH 3 EXH 40 2 x M5 x 0.8 thread depth 9 (for bracket mounting) Applicable cable O.D. 3.5 to 7 (24.5) 64.3 56.8 Details of manual override part (for manual operation) 38.5 7 Type