Model: 40 (Standard), Bar Length: 28 (280mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &

Model: 42 (Dual AC Type), Bar Length: 28 (280mm), Emmiter Cartridge, Material: M (High Energy Saving De-ionizing Cartridge, Silicon), High-voltage Cable Length: 2 (2m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: Q (High-voltage Cable Side), Bar Bracket: F (w/Bracket 2), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 28 (280mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7L (ø1/4" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Bar Bracket: F (w/Bracket 2), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 28 (280mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7L (ø1/4" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Bar Bracket: F (w/Bracket 2), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 28 (280mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7L (ø1/4" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Bar Bracket: F (w/Bracket 2), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 28 (280mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7L (ø1/4" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Bar Bracket: w/o Bracket, Option: X10 (Non-standard Bar Length)

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez , Wetted part material: PEEK or PFA (body/plate), PVDF SUBBASE 1/4-28 THD, VALVE, LVM CHEMICAL VALVE, 2 PORT, 22,

572   Family Description: AUTO-SWITCH ACCESSORY   Class Code: 22   Part Code: 1   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, SeriesModelLH Mount RH MountTypeLoad VoltageLoad CurrentPowerSourceInternal VoltageDropIndicatorLampNCRB1BW30D-T792LD-T791L2 Wire Solid State10~28

protection5 mA or less17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V)5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V)0.08 to 1.5 mm2 (AWG16 to 28

Vertical vacuum entry, With rotating or non-rotating buffer, Pad diameters from 2mm to 50mm, Flat, ribbed, deep, and bellows pad styles, Four different materials available, Vacuum Pad, with Buffer, VACUUM PAD, ZP, ZP2, ZP3, 28 lb

Solenoid on side A 0 2 4 6 8 16 28 30 2 3 1 SV24 V +24 V for valve 5 2 SV0 V 0 V for valve Side D Side U URL http://www.smcworld.com 1 4 3 SW24 V +24 V for input (SI unit side) Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 SW0 V 0 V for input 4 Output No.

Please keep this manual handy for future reference. 3 Bit: 7 0 Byte 2 Offset 3 TDTransmit Data RDReceive Data 4 2 Bit: 7 0 Byte 3 Offset BUS IN: M12 4-pin socket D-coded 1 Bit No. 6 4 6 4 2 0 0 0 Designation Description No. 4 Solenoid on side A 2 4 6 16 28 30 0 8 Output No. 2 1 TD+ Transmit Data + To obtain more detailed information about operating this product, please refer to the SMC website

area mapping Input data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 L L L L SOLV L L L L L L L L L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28

Solenoid on side A 0 2 4 6 8 16 28 30 Side D After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.

Individual grounding should be provided close to the product with a short cable. 0 2 4 6 8 16 28 30 Solenoid on side A Output No. Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.

Please keep this manual handy for future reference. 2 RD+ Receive Data + 1 3 3 TDTransmit Data Bit No. 6 4 6 4 2 0 0 0 RDReceive Data 4 0 2 4 6 8 16 28 30 Output No. Solenoid on side A 2 Side D BUS IN: M12 4-pin socket D-coded (SPEEDCON) (SI unit side) 1 Output No. Solenoid on side B 1 3 5 7 9 17 29 31 No. Designation Description 1 3 5 7 1 1 5 7 Bit No.

IO-Link Device Generic (Example using the ISE20B-L) 28 8.6.9. IO-Link Device IODD (Example using the ISE20B-L) 29 -1No.EX-OMY0032-B 1.Outline The IO-Link Device Tool is an application software for IO-Link developed by Technologie Management Gruppe (TMG hereafter) in Germany, that makes the following operations possible for the IO-Link Module in the EX600 and EX245 series.

Conformance class 3 Yes (Only for IRT switch function) Vendor ID 0083h Device ID 000Ch GSD file GSDML-V2.35-SMC-EX260-FPS-*.xml Certifications EMC directive Yes, 2014/30/EU, EN 61131-2, EN 61131-6 Machinery directive Yes, 2006/42/EC, EN 62061, EN ISO 13849 RoHS 2011/65/EU, EN50581: 2012 TUV Certification Yes, IEC 61508, EN 62061, EN ISO 13849 PROFINET & PROFIsafe Yes UL/cUL Yes,E209424 28

Individual grounding should be provided close to the product with a short cable. 28 30 Hexagon socket head cap screw (M3 x 30): 2 pcs. Seal cap: (for M12 connector socket): 1 pc. Pollution degree D Side (SI unit side) NOTE Output No. 1 9 Solenoid on B side 3 5 7 17 29 31 (Note): Y connectors for external power supply are available as accessories.

PSE57 -28 Current output: 4 to 20 mA Allowable load impedance: 500 or less (at 24 VDC) 100 or less (at 12 VDC) Caution After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty.