+ + 20 + + + + + 20 stations S F G P R P R A, B port size R port 1/8 R port 1/8 N NPT A B B A M5 M5 x 0.8 A, B port M5 x 0.8, C4 P port 1/8 P port 1/8 T NPTF A, B port M5 x 0.8, C4 C4 One-touch fitting for 4 N3 One-touch fitting for 5/32" Type 41 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343How to Order SS5YJ3 41 05 C4 Type 41 Type S41 ( ) Single solenoid coil is on
regulator IN port SRF Booster regulator IN port C C ITV EXH: C EXH: C IC (A) (B) Tank OUT port Rc 3/4 (A) D (B) OUT OUT 355 ITVH 256 256 205 4 x 13 4 x 13 ITVX 50 50 150 150 500 PVQ 250 250 824 (mm) VY1 Drain port Rc 1/4 A 531 570 494 527 576 B 444 479.8 444 479.8 479.8 C Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 1/2 D Note) 519 543 Booster regulator model VBA20A VBA40A VBA22A VBA42A VBA43A VBA
Fig. 7-2 Status indicators of the EX245-DX1 49 No.EX-OMW0011-B 7.6. Block diagram The following figure shows the block diagram of the EX245-DX1. Fig. 7-3 Block diagram of the EX245-DX1 50 No.EX-OMW0011-B 8. Digital Output Module EX245-DY1 8.1. Parts and description Fig. 8-1 Allocation of parts on the EX245-DY1 51 No.EX-OMW0011-B 8.2.
A at the station with the smaller number in the above figure and the B side solenoid to SOL. A at the next station. 1 2 3 4 5 6 7 8 9 10 Terminal no. (Looking it by the double solenoid valve) SOL. () A B () () A B A B A B A B Note) Types with 10, 16, or 20 pin are also available. For details, refer to page 2-4-28.
1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B 6 1/8,1/4 500 1.5 0 1,000 2,000 3,000 6 1/4, 3/8 10 1/4, 3/8 Maximum speed Vmax [mm/s] 1000 3 25 20 1500 4.5 Composite effective area So [mm] Composite effective area So [mm] Composite effective area So [mm] 10
8 @0!7 !9i @2 q r @8#9 $0 $2 w $3 #8 @9 A C B !3 !4 #4 $1 e$8 o $7 !1@1 !6 @5 u !0 $6#6#5 $4 y#8 @6 #3 Section B Section C Section A !2 !2 #1 #0 !2 32 100 80 63 50 40 80, 100 80, 100 Parts list Parts list No. No.
D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F Auto switch model D-A9 D-A9V D-A59W D-F5NTL A A A A A A B B B A B B B B Bore size 125 140 160 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 Provided as guidelines for auto switch proper mounting position (detection at stroke end).
Refer to Fig.1 ) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to Fig.2 ) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B.
Allocated bytes Unit Unit part number Input Output EX600-SEN3 / 4 (32 outputs) 0 4 SI unit EX600-SEN3 / 4 (32 outputs) 4 4 (with diagnostic data) EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16 inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#
B-1 A-1 B-2 A-2 B-3 A-3 Cable color Signal Nil 2 1 6 5 3 4 A A B B COM-A/COM COM-B/ Brown Red Orange Yellow Green Blue S Standard cable Cable color Connector D terminal no. Shield 12 13 7 6 9 8 3 Brown Black Red Black Orange Black Vcc GND A A B B B-4 A-4 B-5 A-5 B-6 A-6 Connector B terminal no.
8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6
A/B) 4/2 5/3 (A/B R) Port size Manifold C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1(P), 5/3(R) port 2(B), 4(A) port VV5Z5-20-01 VV5Z5-20-C6 VV5Z5-20-C8 VV5Z5-21-01 VV5Z5-21-C6 VV5Z5-21-C8 1/8 C6 C8 1/8 C6 C8 0.55 0.49 0.51 0.54 0.50 0.50 0.26 0.25 0.25 0.26 0.24 0.20 2.3 2.0 2.1 2.3 2.1 2.1 0.57 0.37 0.45 0.55 0.36 0.50 0.35 0.32 0.38 0.36 0.32 0.37 2.2 1.4 1.7 2.1 1.4 1.8 1/8 1/8 1/8 1
type) 2 x 1/8 3(R) port = Thread type Manual override 72.8 (Double solenoid dual 3-port) 50.3 (Single solenoid) 2 x 4.5 Mounting hole 81 (Closed center) R 3 P 1 X 36.5 9 32 24.1 P 1 15.6 2 x 1/8 1(P) port = Thread type 10.2 Indicator light Stations 1 2 3 4 5 6 7 8 n D side U side 39.7 With plug connector/light B 2 B 2 20 14 A 4 A 4 5 14.6 2n x C2, C3, C4, M5, N1, N3 <4(A), 2(B) port>
-B Temperature Accuracy (reference value) Models A B AMS20 5 L/min 500 L/min AMS30 10 L/min 1000 L/min AMS40 20 L/min 2000 L/min AMS60 40 L/min 4000 L/min -134No.PF-OMA1007-B Dimensions Standby E/P regulator type NC Specification AMS20/30/40/60A-R/N/F#C Part number P A B C D E J M L AMS20A-#C 1/8 1/4 274.3 214.7 81.7 134.4 25.6 46.2 24 40.1 AMS30A-#C 1/4 3/8 291.8 214.7 87.9 134.4 29.1
(14.2) (b) (8) 2 1 (a) (14) (18) B1 A1 (17.7) 6 5 (c) 2 1 A6 B6 15 16 L (11) (30.7) 12.4 [820m] (a) (b) L E C P -* A B-1 2 L A A-1 1 B B-2 6 ) 8 8m B A-2 5 COM-A/COM B-3 3 ) A 10m COM-B/ A-3 4 ) B 15m (c) Shield ) C 20m Vcc B-4 12 GND A-4 13 A B-5 7 ) A A-5 6 () B B-6 9 B A-6 8 3 (14.2) (b) 2 1 (5.5) (14) (a) B1 A1 5 (17.7) 6 (c) 2 1 (18) A6 B6 (6.3) 16 15 L (11) (30.7) -82No.JXC-OMT0001CN-C
1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 S 8 3 4 + B-1 5 A-1 1 + B-3 2 A-3 8 14.2 B1 A1 17.7 2 1 14 18 10.2 6 A6 B6 5 B1 A1 B3 A3 2 1 5.7 15 16 L 11 30.7 11.4 [820m] A B-1 2 A A-1 1 L B B-2 6 LE-CP-1 B A-2 5 8 8m* COM-A/COM B-3 3 COM-B/ A-3 4 A 10m* B 15m* Shield Vcc B-4 12 C 20m* GND A-4 13
SI unit output No. 0 1 2 3 4 5 6 7 8 9 SI unit output No. 0 1 2 3 4 5 6 7 A B A B B A Void A Void A A B A B B A A A SY Double Double Double Double Double SI unit SI unit Single Single Single Single Single SYJ Stations 1 2 3 4 5 Stations 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link
: = ; > 2 B @ Meter-in type Meter-out type Seal method: Sealant Thread type: R, NPT . 8 : = ; > 2 B @ Meter-in type Meter-out type Component Parts No.
OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System 0 A B C D E F1 G H J1 J2 K Q R1 R2 V (2) Max. 16 stations Kit S Max. 8 P. 2-4-80 Max. 16 stations P. 2-4-82 C Connector kit 1 2 No. of terminals: 8, 1 row Applicable stations 1 to 8 Kit T Max. 8 Max. 16 No. of terminals: 16, 2 rows Max. 16 Applicable
Port size P, A, B R1, R2 Piping Model Side Side Bottom Bottom 1 4 3 8 VS7-1-A02 VS7-1-A03 VS7-1-B02 VS7-1-B03 3 8 1 4 3 8 3 8 1.19-8 Series VS7-6 Manifold Manifold: Series VV71 Standard Specifications SV ISO size q Series ISO size q 1 to 10 Manifold block size Applicable solenoid valve Number of stations SY 1 4 3 8 One-touch fitting: 12 1 4 3 8 A, B-port P, R1, R2-port One-touch fitting: