SMC Corporation of America
Elite Part Number Search
Search Results "VV5FR5-10-101-06N"

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 2 (0 to -101 kPa, SI unit only, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch Fitting

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: J (Vacuum Break Flow Adjusting Needle, Round Lock Nut), 1st Nominal

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: B (Switch, 0 to -101 kPa, SI Units Only, NPN 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric)

Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection