Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED, DIN (DC), VALVE
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV20001/41.5 MPa0.2 to 1 MPa1/80 to 60C (1)20240.27100, 200
pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV50003/41.5 MPa0.2 to 1 MPa1/80 to 60C (1)1131321.60100, 200
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, CYL, COMPACT, DBL ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, FX, 12MM
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, CYL, COMPACT, DBL ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, HX, 20MM
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, CYL, COMPACT, DBL ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, HX, 20MM
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, CYL, COMPACT, DBL ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, HX, 20MM
Stainless steel, PVC, Copper brazing (heat exchanger), Bronze, BrassSingle-phase 200 to 230 VAC 50/60 Hz Allowable voltage fluctuation ?
Stainless steel, PVC, Copper brazing (heat exchanger), Bronze, BrassSingle-phase 200 to 230 VAC 50/60 Hz Allowable voltage fluctuation ?
Stainless steel, PVC, Copper brazing (heat exchanger), Bronze, BrassSingle-phase 200 to 230 VAC 50/60 Hz Allowable voltage fluctuation ?
Stainless steel, PVC, Copper brazing (heat exchanger), Bronze, BrassSingle-phase 200 to 230 VAC 50/60 Hz Allowable voltage fluctuation ?
140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types:? Rc, NPT, G, Auto switch capable, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, MX, 40MM NCQ2-Z DBL-ROD AUTO-SW, 7.63750 lb
10 to 60C50 to 500 mm/s(Adjuster option/Metal stopper: 50 to 200 mm/s)Rubber bumperShock absorber (Option is not available for Series MXP6 and MXP8)None (Adjuster option/Metal stopper)Non-lubeStandard equipment (Adjustable on one side only, for the MXP6)Rubber stopperShock absorberMetal stopperReed auto switch (2-wire, 3-wire) Solid state auto switch (2-wire, 3-wire)2-color indication solid
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 1.276 lb
pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV50003/41.5 MPa0.2 to 1 MPa1/80 to 60C (1)1131321.60100, 200
Please contact us for the latest version.sales@ocaire.com, TANDEM XRAY-S-2200-200 W/ G, ACTUATOR, GRIPPER, LC, 32MM GRIPPER, .00000 lb
Please contact us for the latest version.sales@ocaire.com, TANDEM XRAY-1250-200 W/ G, ACTUATOR, GRIPPER, LC, 32MM GRIPPER, .00000 lb