30 40 0 40 80 120 160 100 0 200 300 Outlet air flow rate (l/min (ANR)) Outlet air flow rate (l/min (ANR)) IDG30H (Type B products group) IDG50H (Type B products group) P1 = 0.3 MPa 0 P1 = 0.3 MPa 0 Outlet air atmospheric pressure dew point (C) Outlet air atmospheric pressure dew point (C) P1 = 0.5 MPa P1 = 0.5 MPa 10 10 P1 = 0.7 MPa P1 = 0.7 MPa 20 20 HA 30 30 AT 40 40 ID 50 50 600 0 200
Other than positioning mode: Actuator travel distance at 10 [m/pulse] per pulse. Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.
Length per roll Symbol Length Tube I.D. 20 100 20m 100m Color indication Symbol Color B Black Model O.D. mm I.D. mm Min. bending radius mm Note2) TAU3220 3.2 2 10 TAU0425 4 2.5 10 TAU0604 6 4 15 TAU1065 10 6.5 27 TAU1208 12 8 35 TAU0805 8 5 20 Length 20m 100m Roll Reel Specifications Operating fluid Air Max. operating pressure 131psi (0.9MPa) at 68F (20C) Note1) Burst pressure Refer to burst
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
type CR Rear clevis with ball joint A B C D EN ER F G E L M N P H R (mm) 0.2 maxi JS15H7 -0.1 maxi H11 H13 H13 0.5 0.5 0.5 32 32.5 10.5 22 10 14 15 30 10 6.6 45 10.5 5.5 5 40 38 12 25 12 16 18 35 10 6.6 55 11 5.5 5 50 46.5 15 27 16 21 20 40 10 9 65 15 6.5 5 51 19 63 56.5 15 32 16 21 23 45 12 9 75 15 6.5 5 80 72 18 36 20 25 27 45 14 11 95 18 10 5 100 89 18 41 20 25 30 55 16 11 115
ISO size 1 Series VQ7-6 ISO size 1 Max. 10 stations 0.43n + 0.49 (n: Stations) 1/4 3/8 Bottom Note) When equipped with control unit, 1 or 2 stations are used for mounting. 3-10-11 12 Series VQ7-6 DIN Terminal Type VV71-100 80 100 2n-1/4, 3/8 80 23 37 9 14 9 15 U side U side Manual override R4.5 R4.5 Indicator light P = 43 53.5 P = 43 53.5 B B B B 9 9 B 23 20 SMC SMC SMC 9 A PA A B B A PA
-10 (INC) c 10[mm] 0 10 20 30 40 50 [mm] -27- 4 a b c d e f g h i j k No. 1 2 mm/s mm mm/s^2 mm/s^2 % % mm/s % mm mm mm 0 ABS 100 20.00 3000 3000 80 40 30 100 10.00 20.00 20.00 No.00[mm] 20[mm]20[mm] 1 10 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP 2 k INPON g 30 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP INPOFF () k g BUSYONOFF -28- 5 a b c d e f g h i j k No. 1 2 mm/
temperature C 2 to 45 Circulating fluid CH1 : Clear water / CH2 : Clear water,DI water (pure water) 1 Set temperature range C CH1 : 15 to 25 / CH2 : 20 to 40 Cooling capacity2 kW 9 1 8 19 1 8 26 1 8 Heating capacity3 kW 1.5 1 4.5 1 6.5 1 Temperature stability 4 C CH1 0.1 CH2 0.5 Rated flow rate (Outlet) L/min 45 10 45 10 125 10 (0.43MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa
Size/Standard stroke (mm) Angle of rotation 32 40 5, 10, 15, 20, 25, 30, 40, 50, 75, 100 A B 80 to 100 170 to 190 Refer to p.1.5-18 and 1.5-19 for middle and long strokes other than standard stroke.
Connection thread size Wrench tightening angle after hand-tightening [deg] Proper tightening torque [Nm] G1/8 10 to 20 3 to 4 G1/4 15 to 35 4 to 5 G3/8 15 to 35 8 to 9 G1/2 15 to 35 14 to 15 600 AS-FS Series Specific Product Precautions 3 Be sure to read this before handling the products.
-10 Grommet 10-20-11 Connector 10-20-12 Band 10-20-13 Terminal conduit 10-20-14 10-20-13 DIN terminal 10-20-14 10-20-15 Grommet Rail 10-20-16 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Connector 10-20-17 Reed Switch Solid State Switch Grommet 10-20-18 Tie-rod
D-F9 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 Switch Hysteresis D-F9W 6 15 19 41 46 43.5 Proper auto switch mounting positions (Series CEP1 ) (mm) Bore size (mm) 12 Auto switch model Symbol 20 A B A B A B A B A B A B A B 75.2 82 Switch operating position (ON) D-A90, A93, A96 7.9 12 75.2 82 D-A90V, A93V, A96V 7.9 12 Hysteresis Reed switch: 2mm or less Solid state switch: 1mm or less 79.2 86
Note) ( ): Long stroke 1.6-8 Standard: Double Acting Single Rod Series CG1 With Mounting Bracket Axial foot (mm) Z ZZ Bore (mm) LT W X B LC LD LH LS LZ M LX Y Without rod boot With rod boot Without rod boot With rod boot 67+l 74+l 75+l 83.5+l 95.5+l 95.5+l 104+l 104+l 20 25 32 40 50 63 80 100 10 10 10 10 15 15 16 4 4 4 4 5 5 6 6 6 6 45 (53) 3 3 3 3 34 20 44 49 58 71 86 3 32 36 44 54 66 82
) 0.6 0.7 Critical pressure 0.65 [658] (158) 0.5 0.6 0.55 Sonic [656] (151) 0.5 0.4 0.45 [654] (143) 0.4 0.3 0.35 0.3 [650] (133) 0.2 0.25 0.2 [646] (120) 0.15 0.1 0.1 0.05 2 2 2 2 3 2 3 2 3 2 03 04 VX211 VX22 VX23 VX2 4 VX2 50 VX2 60-02 VX2 602 10 15 5 3 5 10 15 20 25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated
(Unit: mm) Separate position ranges can be set for up to two outputs: AREA A and AREA B. The position ranges should be set as follows: Position 1 Position 2. Part No. Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right.
6 10 Bearing stopper Size 6: Aluminum alloy Size 10: Carbon steel 11 Motor plate Aluminum alloy Anodized 12 Guide ring Aluminum alloy Size 10 only 13 Bearing 14 Bushing Oil impregnated sintered copper alloy 15 Soft wiper r w !5 !4 !3 e u !
Metal bowl Optional specifications B B B B B N.C.: Gray N.O.: Black B B O S O S M5 x 0.8 Width across flats 17 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 (mm) Bracket mounting size Accessory specifications With auto-drain Standard specifications Port size Model B 85 115 170 204 208 284 297 P 28 57 73 73 D 25 40 53 70 70 90 95 C 7 10 14 18 20 24 24 B 67 97 129 165 169
Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14
(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series
300 400 500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500