SMC Corporation of America
Elite Part Number Search
Search Results "ALDU600-N10-S2"

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Do not drop, bump, or apply excessive impacts (1000 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause a malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N.

(Error number 5) Blue S1 White Vs Black S2 Set Pressure Range Vs: Power supply 24 VDC 12 to 15 VDC The regulating pressure range, by unit of standard measured pressure, is shown in the table below. One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.

S1 S2 Effective area ratio 2.3 : 1 Pressure loss: Large K M 3 Without nozzle 3 H Pressure Loss of Air Gun Only Effective area (mm2) Upstream side S1: 15 Nozzle side S2: 6.4 D S1 : S2 = 2.3 : 1 Effective area ratio Nozzle size (mm) Number of nozzles Supply pressure Regulator pressure Outlet pressure Pressure loss 3 MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,

Do not drop, bump or apply excessive impact (1,000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 2. Hold the product from the body side when handling. The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3.

.: 1.4 mm Vibration resistance1 30 m/s2 Without pressure sensor/switch With pressure sensor 20 m/s2 With pressure switch Impact2, 3 resistance 150 m/s2 Without pressure sensor/switch With pressure sensor 100 m/s2 With pressure switch Standards CE marking, RoHS 4 Refer to the Valve assembly on page 32 for the valve model number. 5 ZK2-VAmR: After instantaneous energization of the supply valve

3280 ft/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case) 1000 VAC for 1 min.

Do not drop, bump or apply excessive impacts (300m/s2 or greater for reed switches and 1000m/s2 or greater for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 * Note) Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 54 - 5.6.4 Move distance Configuration

P16 s1 s1 s1 s1 s2 s2 s2 s2 ... ... ... ... s32 s32 s32 s32 0.5mm) 1 2 , 2. 30mm 30mm 3.

P16 S1 S1 S1 S1 S2 S2 S2 S2 ... ... ... ... S32 S32 S32 S32 0.5mm) 1 2 2. 3.

Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. Observe the proper tightening torque for mounting an auto switch.

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Not required (1) VF Non-locking push type Unrestricted 300/50 m/s2 (2) Plug-in type VFR VP4 Dustproof 100, 200 VAC (50/60 Hz), 24 VDC 15 to 10% of rated voltage 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz 1.8 W Conduit terminal Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800

Large diameter piping Small diameter nozzle S1 Pressure loss: Small With nozzle S2 Effective area ratio 2:1 6 Pump capacity Previous rate Pressure Pump head (electric power) Pressure loss: Small P Pump outlet Nozzle outlet Discharge rate Main Points Improve pressure loss. Improve the effective area ratio with the upstream side by using a small diameter nozzle.

Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult P/A when used under conditions which may cause condensation on the exterior of the

Conversion example for a 8[mm] lead actuator driven at an acceleration of 3000 [mm/sec2] Acceleration/Deceleration time constant (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) Rated Motor Rotation Speed (mm/s) Acceleration time constant/deceleration time constant (ms) = {Rated rotation speed (r/min) 60 (S) } x screw lead (mm) x 1000 Acceleration/deceleration speed (mm/s2) *Note)

Conversion example for a 8[mm] lead actuator driven at an acceleration of 3000 [mm/sec2] Acceleration/Deceleration time constant (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) Rated Motor Rotation Speed (mm/s) Acceleration time constant/deceleration time constant (ms) = {Rated rotation speed (r/min) 60 (S) } x screw lead (mm) x 1000 Acceleration/deceleration speed (mm/s2) *Note)

The station address is set using the rotary switches S1 and S2. (1) Settings of the Rotary Switches S1 and S2 Set the station address using the rotary switches S1 and S2.