First find the ratio of the discharge rate for fresh water when viscosity is 15mPa s from the graph to the left. It is determined to be 48%. 2. Next, the viscosity of 15mPa s and the discharge rate of 200l/min in the required specification example are converted to the discharge rate for fresh water.
Thread type Common EXH port size 04 1/2 Nil T F Rc NPTF G 06 3/4 S Silencer dedicated for ZZMA (ZZM-SA) Indicate the ejector model no. below the manifold base no. Example) Manifold model no.: ZZMA04-SR (1 pc.)
N Body 2Yq 3-3/s s-Y4 6 1 A 1 y 2 9-2 B Brackel D Threaded draln poft (Female) except 220. Port slzo o2% o3-% 04-'/z 06 % to1 741'/z 20-2 Thread 1 Male 2fumale. ,NAMC220, 32O,520 only HowTo Select Flow Characteristics Supply prossure: 71 PSI Supply pressurei 71 tl 12 10.5 I 6 ! e E , q 1.5 8 1 2 1 6 2 0 Cylinder speed (in/sec.)
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.
X15 AMHSCJJ Body size* * Thread Semi-standard* specification Port size* X6 A:~S~J .ize*Thread1 Semi-standard * specification * Port size (Not available with element * Accessories service indicator "T".) Accessories* Dimensions Dimensions ~.~ CD ~~
in X, Y, Z directions, 2 hours each 490m/s in X, Y, Z directions, 3 times each 290g (without lead wire) 250g (without lead wire) Equivalent to IP65 3/8 1/2 1/8, 1/4 Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min or l).]
The product has a fan(s) and could cause serious danger to operators. 8.2 Specifications Cool outlet air (10oC) can be supplied.
R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF
The size should be 6 or 4.5 and length should be a maximum of 20 m, but the collector,s performance will decline as the tube gets longer, so be sure to use as short a connecting tube as possible.
Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.
None Nil ASV120F/E220F Type With seal S ASV310F/410F/510F 1 2 Tee Elbow Note) Applicable tubing O.D. Metric size Flame resistant resin body as standard.
Auto Switch Common Specifications Auto switch style Solid state switch Reed switch Current leakage 3 wire: 100 A or less, 2 wire: 1mA or less None Operating time 1ms or less (3) 1.2ms Shock resistance 300m/s 2 1000m/s 2 Insulation resistance 50 M or more at 500MV DC (between lead wire and the case) 1000V AC/min. (between lead wire and the case) 1500V AC/min.
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1 Series ASG Needle Valve: Flow Characteristics ASG220F-M5 ASG221F-M5 ASG320F-01 ASG321F-01 ASG420F-02 ASG421F-02 1.5 Inlet pressure: 0.5 MPa Inlet
(mm) Note) Type 04 06 08 10 12 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Made to Order (For details, refer to page 659.) Control type Note) For applicable tubing O.D. selection, refer to the Model.
Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Applicable models Flow rate (l/min) Port size Applicable models Output specification Symbol Symbol 100 200 500 50 10 PF2A710/PF2A750 PF2A711/PF2A721, PF2A751 27 NPN open collector 2 outputs 01 02 03 04
Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Applicable models Flow rate (l/min) Port size Applicable models Output specification Symbol Symbol 100 200 500 50 10 PF2A710/PF2A750 PF2A711/PF2A721, PF2A751 27 NPN open collector 2 outputs 01 02 03 04
SRF 1 07 11 0 S S 1 With nut Body size 1 3 5 Fitting type Pilot port thread type Made to Order (Refer to page 887 for details.)
(LCD ) 4.DIN 7 1-2 30mm No. 1-3 30mm Err6 1-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm 30mm Err6: 30 20 50mm/sec100mm/sec :50cm :0.5MPa 2. 2-1 CE2CEU2 8 NO 1 0 0 2 0 0 2 0 0 YES (kgf) (kgf) 1 0 0 8 0 NO 1 0 0 1 0 0 8 0 6 3 6 3 5 0 YES 5 0 0 0 NO 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 mm/s mm/s YES OK (), ? NO YES NO , , ?
3-1 IDX-OM-W094 3.2 3.2.1 z (85%) z z z z z z 245 050 z z () z z z z z 2000m z z z 600 mm 600 mm 600 mm 600 mm 600 mm z z z 3.2.2 z z 7 7.3 z IDF-AB500 14 1 IDFA60/70/80/90 Series 3-2 IDX-OM-W094 3.2.3 z z z z z 60 z 65 65 z z z z z z z OUT IN (IN) (OUT) IN OUT IDFA60/70/80/90 Series 3-3 IDX-OM-W094 3.2.4 z 12mm 5m8mm z z z z SO O S