How to Order 10 30 CUX D Without auto switch 10 A90 30 CDUX D With auto switch Number of auto switches With auto switch (with built-in magnet) Nil S 2 pcs. 1 pc. Microspeed cylinder Bore size 10 16 20 25 32 Auto switch type 10mm 16mm 20mm 25mm 32mm Nil Without auto switch Select auto switch type number from the table below.
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90--Reed, AC Volt, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: A90--Reed, AC Volt, Horizontal, 0.5M
Pressure Control Equipment Industrial Filters A !4 Spring return !5 !6 !4 Spring extend A A-A section (port on rod end) A-A section (port on rod end) With auto switch Spring return Spring extend !4 !5 !6 !4 A A Auto Switch Auto Switch A-A section (port on rod end) A-A section (port on rod end) The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).
to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
Single vane type Double vane type +4 0 9 0 a a r r n n e n n g g g o o e e n i i t t 1 2 a a a 8 7 r t t 0 -5 +4 0 o o 0 0 n R R +4 0 +4 0 o 0 i 0 0 t a 9 1 t o e e R g g n n a a r r n n o o i i t t a a Chamfer Chamfer t t o o Chamfer A port B port Chamfer A port Chamfer R R A port B port B port A port B port A port B port For size 40 actuators, a parallel keyway will be used instead
A Dimensions except A, L and L1 are the same as rod side flange style.
Maintain a minimum cylinder separation of 40mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Maintain a minimum cylinder separation of 40mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Maintain a minimum cylinder separation of 40mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
Maintain a minimum cylinder separation of 40mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Devise a safe system so that if a person engages the emergency stop, or if a safety device is tripped during a system malfunction such as a power outage, the movement of the cylinder will not cause a hazard to humans or damage the equipment. Avoid synchronized operation using cylinders only.
Seal guide B Slide plate Spacer 21 22 Side seal unit MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A 23 24 Hexagon socket head cap screw Chromated Chromium molybdenum steel 25 Replacement Parts: Seal Kit 20 40 50 25 32 63 16 No.
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
Do not use a load that generates surge voltage. If a surge voltage is generated, the discharge occurs at the contact, possibly resulting in the shortening of product life. If driving a load such as a relay that generates a surge voltage, use an auto switch with built-in contact protection circuit or use a contact protection box. 3.
set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) CKQ D-M9ANote 2) BMA3-040S (A set of a, b, c, e) BMA3-050S (A set of a, b, c, e) BMA3-063S (A set of a, b, c, e) Auto switch Switch bracket (Resin) Transparent (Nylon)Note 1) d e White (PBT) c Switch holder b Auto switch mounting screw a * Band (a) is mounted so that the projected part is on the internal side