-01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions, make determinations after using the P/A
Port size port 3(R) port 1(P), 2(A) Body size Rated voltage (Only with solenoid) 04 06 10 10 12 14 20 1 2 3 4 1 2 100 VAC 50/60 Hz 1 2 3 (Ex.)
200 100 100 500 400 300 200 100 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 3000 3000 2000 2000 160 140 1000 1000 700 800 900 700 800 900 125 Load weight: m(kg) Load weight: m(kg) 600 600 160 500 500 400 400 140 320 125 300 300 200 200 280 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 7
Recommendable Air Flow ln/min Model Port Size NZFA100-T01 18 50 NZFA200-T02 14 200 Cup D I M E N S I O N S A P P L I C AT I O N T O VA C U U M P U M P S Y S T E M H O W T O O R D E R (N)ZFA A I R S U C T I O N F I LT E R (N)ZFA A C C E S S O R I E S TYPE N None L With Bracket -Left R With Bracket -Right 100 500Nl/Min 200 200Nl/Min P O R T S I Z E P O R T T H R E A D 01 1/8 02 1/4 Nil PT*
JIS symbol 5 Port 4 Port Fluid Specifications Air 22~100 (0.15~0.7) 15~100 (0.1~0.7) 22~100 (0.15~0.7) 2 Position single 2 Position single 2 Position single 2 Position double 3 Position 2 Position single 2 Position double 3 Position A B A B Operating pressure range PSI (MPa) P R R P R Operating pressure to 100 (Operating pressure to 0.7) 15~100 (0.1 to 0.7) 22~100 (0.15 to 0.7) Max.140 Not
Class 3 ground Ground resistor 100 or less Command pulse (MAX.225/kpps) PULS SIGN P Incremental encoder SIGN CLR P Deviation counter clear signal (active high) 2CN PG CLR P Be certain to treat the shielding wire terminals.
It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less. Specifications Base mounted (SYJ714R, SYJ724R) Applicable model 100 kPa to 0.7 Main pressure Operating pressure range MPa 0.15 to 0.7 External pilot pressure P, R port 1/8, 1/4 Note 1) For manifold base, refer to page 39.
, 150, 200, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact P/A if the maximum stroke will be exceeded.
100 100 100 125 125 125 Page 11 150 150 Low thrust with high rigidity type MXQB 10 10 10 10 10 20 20 20 20 20 30 30 30 30 30 40 40 40 40 40 Stroke 50 50 50 50 50 75 75 75 75 75 100 100 100 100 125 125 125 Page 53 150 150 Single side-ported type MXQC 10 10 20 20 30 30 Stroke 40 40 50 50 75 75 Page 67 100 Height interchangeable type MXQ 10 10 10 10 10 10 20 20 20 20 20 20 30 30 30 30 30
Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC Inrush 2.6 VA (11.7 mA), Holding 2.6 VA (11.7 mA) 220 VAC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Note 1) Use dry air to prevent condensation when operating
125 40 56 41 23 12.5 25 37.5 50 75 100 125 50 64 51 25 12.5 25 37.5 50 75 100 125 150 63 64 51 25 12.5 25 37.5 50 75 100 125 150 80 68 56 29 12.5 25 37.5 50 75 100 125 150 175 200 100 76 61 29 12.5 25 37.5 50 75 100 125 150 175 200 125 82 75 27 10 20 30 40 60 80 100 120 140 160 180 200 [mm] Rubber Bumper Bore size [mm] h 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401
00 I 1.8, Eccentrlc distance: L(mml | , ^-l^-t I I fti-+i-*-t'-1 | l t ' + t r Over 100 stroke Non-rotating accuracy of plate Non-rotatng accurary 0 10.09. $0Pi8$ I)(P _ uomlam neouil nctun loxt Fifl.[r[ $$or tE L X P B T I o.l O",u*o, "r,"p"f i?'Ic.dffiAil a Number ot auto switch t1--'l-G'l [?
Applicable shaft types: S, W, Y d1 = Q1 = M L2 + (3 x P) L1 = L2 = (mm) Size 30 50 63 80 100 Q2 = M Thread M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 Rc1/8 Rc 1/4 2.5 4 5 4 5 6.8 (mm) (mm) d1 Size 30 50 63 80 100 100 Q2 M3, M4 M4, M5, M6 M4, M5, M6 M4, M5, M6, M8 M5, M6, M8, M10 Size 30 50 63 80 100 100 6.8 8.5 10.3 8 6.8 8.5 10.3 8 11 2.5 4 to 7 4.5 to 18 6.8 to 11 6.8 to 13
Applicable shaft types: S, W, Y d1 = Q1 = M L2 + (3 x P) L1 = L2 = (mm) Size 30 50 63 80 100 Q2 = M Thread M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 Rc1/8 Rc 1/4 2.5 4 5 4 5 6.8 (mm) (mm) d1 Size 30 50 63 80 100 100 Q2 M3, M4 M4, M5, M6 M4, M5, M6 M4, M5, M6, M8 M5, M6, M8, M10 Size 30 50 63 80 100 100 6.8 8.5 10.3 8 6.8 8.5 10.3 8 11 2.5 4 to 7 4.5 to 18 6.8 to 11 6.8 to 13
186 q Installation Distance and Discharge Time p. 182 Alarm p. 186 w Static Neutralization Range p. 183 Mode Switch Setting p. 187 e Pressure Flow Rate Characteristics p. 184 Wiring p. 187 Dimensions p. 188 How to Order p. 185 Accessories (for Individual Parts) p. 185 Related Products p. 189 Specifications p. 186 AC Adapter Specifications p. 186 Specific Product Precautions p. 190 Parts
80 200 200 63 100 80 100 100 50 40 100 100 Load weight: m [kg] Load weight: m [kg] CJ1 63 50 40 30 50 40 30 32 50 40 CJP 20 20 32 CJ2 10 10 CM2 5 4 3 5 4 3 C85 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 C76 s] Maximum speed: V [m m/ s] Maximum speed: V [m m/ CG1 Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa MB 1000 1000 100 80 MB1 500 400 300 500 400 300 63 63 63 100 80 CP95
559-4 How to Order p. 560 Specifications p. 561 Weight p. 562 Construction p. 564 Dimensions Rod End Configuration Round Bar p. 566 Rod End Configuration Chamfered (Non-rotating Piston Rod) p. 567 Rod End Configuration Roller p. 568 Rod End Configuration Lever (Fixed Absorber Type) p. 569 Rod End Configuration Lever (Adjustable Absorber Type) p. 570 Rod End Configuration Lever (Adjustable
32 to 63 40 to 100 40 to 100 40 to 100 / 1 8 / 1 4 / 1 4 4.1-35 / 3 8 / 1 4 / 3 8 / 1 2 Applicable tube O.D Applicable cylinder bore size (mm) Page Metric size (mm) Inch size (Inch) Model Port size in cylinder side M5 / 1 8 / 5 32 / 3 16 / 1 4 / 5 16 / 3 8 / 1 2 3.2 4 6 8 10 12 With One-touch Fittings/Elbow 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS12l 1FG-M5 AS22l 1FG-01 AS22l 1FG-