Q=226S P(P2+0.1013) Sonic flow : P1+0.10131.89(P2+0.1013) Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Pressure differential (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] When the air temperature is different, multiply the flow rate calculated with the above formula by the following coefficient for compensation. -20 1.08 -10 0 10 30
Options p. 8 Optional accessories p. 7 Auto Drain Valve Longer life, Higher resistance to foreign matter Shape prevents condensate accumulation Non-sliding part reduces the catching of foreign matter Poppet type Diaphragm type Condensate and foreign matter are discharged completely. Easier maintenance V One-touch mounting and removal of the bowl is possible without using any tools.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
Compact and Low Profile Mechanical Joint Rodless Cylinder Compact and Low Profile Mechanical Joint Rodless Cylinder 4058mm 25/37mm 16/28mm 4058mm 25/37mm 16/28mm Reduction in height by 30% over other P/A rodless cylinders Parallel arrangement of the guide and the actuating unit results in compact design.
[] 60Hz 50Hz Fig 9.5-1 Heating capacity(HRS012--10, HRS018--10) 9.5.2 HRS012--20,HRS018--20, HRS024--20 1000 1000 Ambient Ambient temperature temperature 800 800 5 20 25 5 Heating capacity [W] 20 25 32 40 [W] 600 600 32 40 400 400 200 200 0 0 5 15 25 35 45 5 15 25 35 45 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9.5-2 Heating capacity(HRS012--20, HRS018
Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at
-X14 424 Ionizer IZS40/41/42 Series Specifications IZS41(NPN) IZS41-P (PNP) IZS42(NPN) IZS42-P (PNP) IZS40 Ionizer model Dual AC 6,000 V AC, DC Corona discharge type Ion generation method Method of applying voltage Applied voltage Offset voltage Note) AC, Sensing AC, DC 7,000 V IZS IZS Within 30 V Air (Clean dry air) 0.5 MPa or less 0.7 MPa 6, 8, 10 Fluid Operating pressure Proof pressure
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at
Note 4) When ordering the body only, select the symbol from to respectively. 2020 PVQ Specifications VEF VEP Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p
Note 4) When ordering the body only, select the symbol from to respectively. 2020 ITVX Specifications PVQ Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p)
relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 2 XL-OMY0002 / 1 1.5 *3) 3)1 1 () 3 XL-OMY0002 1 &/ 1.52 2 ( ) 5 5 P-
NO YES NO YES YES NO NO NO YES P.10 9 YES YES NO 1? 14.5 ?
If the power should not come back on, please contact P/A for an inspection.
, depth XB O Q 2-M4 x 0.7, thread depth 8 (mounting threads) 20 20 (Open DO) (Closed DC) FX FY FZ CB 7 4-M3 x 0.5, thread depth TB Attachment mounting threads P (finger opening port) Open EO Closed EC K 2H9 +0.025 0 J 2 P (finger closing port) G I Auto switch mounting groove positions (2 locations) MHS2-16D MHS2-20D MHS2-25D 5 6.5 5 3 24 5 3 24 6 3 5 4.5 24 4 4 4 33 33 33 (mm) I 4 5 5 Model
With end lock (R) Functional option Axial piping type (P) For detailed specifications of adjuster options and functional options, refer to option specifications on pages 3 and 4. Standard Strokes Order Made Order Made Specifications Model Standard stroke (mm) For order made specifications of series MXQ, refer to page 42.
2V Assy Assy 18 - No.ZB-OM00301 O Assy V Assy Assy V Assy Assy 19 - No.ZB-OM00301 1TK1-123 2 3 1VKJ 2 3 1 0.1 2 0.1 3 0.15 -0.2 2 20 - No.ZB-OM00301 () ( ) ONOFF () 0.1Nm 1 ON 0 ) () () 1 (PA) 0 (AR) () 21 - No.ZB-OM00301 AXT661-12 0.2~0.33mm 2 (1.7mm) ) DXT170-71-1 3.2~3.7mm (DXT170-75-1) 2 0.2~0.33mm (1.7mm) (ACB (1mm) 22 - No.ZB-OM00301 N.C. 300 600
Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Specifications ISE30 0 to 1MPa 0.1 to 1MPa 1.5MPa 0.001MPa Air, Inert gas, Non-flammable gas ZSE30 100 to 100kPa 101 to 101kPa 500kPa 0.2kPa Rated pressure range Regulating pressure range Proof pressure Setting/Display resolution Fluid Power supply voltage Current consumption Switch output Note 1) 12 to 24VDC 10%, Ripple (p-p
BG GP B G P Note 1) Compared with ARX20, ARX21 is the product which adjusting spring has only been changed. It is not the product, which does not allow the pressure more than 0.3 MPa. Note 2) Pressure gauges are shipped together, (but not assembled).