SMC Corporation of America
Elite Part Number Search
Search Results "CDLSB125TN-700-D"

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC Manifold. 700 lb.

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC MANIFOLD. 700 lb. VVM.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER LOCKING, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, TE, 125MM CLS1 DBL-ACT AUTO-SW, 66.13867 lb

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 700 (7"), Port Location: Perpendicular, Auto Switch: H7A1L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 3M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 700 (7"), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 700 (7"), Port Location: Perpendicular, Auto Switch: B (Band Mounting)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 700 (7"), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M

Cylinder Inner Diameter: D(φ): 80, Stroke: L(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 100, Stroke: L(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead