Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: N (Rubber Bumper), Bore: 40mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 100mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot
Magnet: None, Mounting: B (Basic), Cushion Type: N (Rubber Bumper), Bore Size: 20mm, Stroke: 100mm, Thread: F (Female Rod End), Rod Boot: None
Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: N (Rubber Bumper), Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Type: A (Air Cushion), Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot
Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Direct mount: double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 300mm, Mounts: direct to
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,
Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, front and rear
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: C73, Lead Wire Length
Magnet: Built-in Magnet, Mounting: B [Basic (Double-side Bossed)], Bore Size: 32mm, Port Thread: Rc, Stroke: 100mm, Rod End Thread: Female Rod End, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Type: Air Cushion, Bore: 40mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 100mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Basic, Type: Rubber Bumper, Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in Magnet, Mounting: Head Flange, Type: Air Cushion, Bore: 40mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 100mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewire Connection: 3m, Number: -
Magnet: Built-in Magnet, Mounting: Basic, Type: Air Cushion, Bore: 63mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: 3m, Number: -, X Option
Magnet: Built-in Magnet, Mounting: Basic, Type: Air Cushion, Bore: 32mm, Port Thread Type: G, Stroke: 100mm, Thread: Female Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Auto Switch Rail Right
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: M9P, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: NPT,