SMC Corporation of America
Elite Part Number Search
Search Results "CDP-4A"

Repeat calculation. 72 48 Device-specific diagnostics. 73 49 Save i-Parameter watchdog time exceeded. 74 4A Restore i-Parameter watchdog time exceeded. 75 4B Invalid S_iParCRC. Correct value. 76 4C F_Block_ID is not supported. Check device description. 77 4D Reserved. 78 4E Reserved. 79 4F Non-specified (unknown) error.

OMY0006CN 20.DPROFIsafe Table 21-1 FError code dec hex 64 40 F_Destination_Address FModulePROFIsafe PROFIsafe F_Destination_Address 65 41 F_Destination_Address 0hex Fhex 66 42 F_Source_Address 0hex Fhex 67 43 F_WD_Time 0ms 68 44 F_SIL SI SIL3 SIL3 F_CRC_Length F-ModuleCRC 69 45 70 46 F_Parameter F-Module V2 71 47 F-ModuleCRC CRC F72 48 73 49 watch dog i-Parameter 74 4A

Fig. 6-3 Thermal relay and circuit protector location and statuses Table 6-4 Setting value of the thermal relay Model For the compressor For the pump HRS100-A/W-2018A 6.6A HRS150-A/W-2025A HRS100-A/W-4012A 4A HRS150-A/W-4015A HRS100-A/W-4612A HRS150-A/W-4615A 5. Fasten the front cover of the electrical unit.

Circuit protector for DC power supply Circuit protector for phase board Thermal relay reset button for pump Thermal relay reset button for compressor Fig. 6-3: Thermal relay and circuit protector location and statuses Table 6-4 Setting value of the thermal relay Model For the compressor For the pump HRS200-A*-46-*S 18A 4A 5. Mount the front panel of the electrical unit.

Note Mounting bracket DXT010-37-4A Common exhaust type DXT010-37-3A Individual exhaust type (with O-ring and screws) DXT010-36-2A Common exhaust type Blanking plate Individual exhaust type Thread type (Refer to catalog How to order.) Mounting When the solenoid valves are mounted on the manifold base, the mounting orientation is decided.

pressure: 0.09MPa Max. pressure: 0.1MPa Wetted materials SUS303, SUS304, EPDM, Ceramic, PPS glass 30%, Carbon Polyethylene, Polyurethane Piping port size Circulating fluid IN/OUT : Rc1/4 Circulating fluid drain : Rc1/4 Circulating fluid IN/OUT : Rc3/8 Circulating fluid drain : Rc1/4 Power supply voltage Single phase AC100-240V, 50/60Hz Current consumption 8A(100V) to 3A(240V) 10A(100V) to 4A

Wetted materials SUS304 Circulating fluidEthylene glycol 20% Circulating fluid flow rate3L/min Facility water flow rate10L/min 2500 2500 Power supply Single phase AC100 to 240V(+/10%), Single phase AC200 to 240V(+/10%), 50/60Hz 50/60Hz 2000 2000 Facility water temp. 35deg.C Current consumption Max.10A(100V) Max.7A (200V) Max.6A (240V) Heating capacity W Facility water temp. 20deg.C Max.4A

In case of 2000 mm of lead wire For DC For AC VEX3122-015LO1 VEX3122-011LO1 SY100-30-4A-20 SY100-30-1A-20 Connector Assembly with Cover Connector assembly with dust proof protective cover. Effective to prevention of short circuit failure due to the entry of foreign matter into the connector.

So for example, the EX245-SPN3A can use 4A and a loop through current of 6A can be drawn between connectors XD1 and XD2" 37 No.EX-OMW0011-B Table. 6-2 Specifications (continued) Item Description EX245-SPN1A EX245-SPN2A EX245-SPN3A Fieldbus Bus protocol PROFINET I/O Conformance Class C Yes (Only for IRT switch function) FSU (Fast Start Up) Yes MRP (Media Redundancy Protocol) Yes MRPD (Media