a lead wire cover on the auto switches for size 50 and 63 cylinders.
-CG1RN25 11-CG1RN32 11-CG1RN40 11-CG1RN50 11-CG1RN63 50 63 20 25 32 40 50 63 1/4 Non-lube Double acting, 25, 50, 75, 100, 125, 150 Single rod 25, 50, 75, 100, 125, 150, 200 1/8 25, 50, 75, 100, 125, 150, 200, 250, 300 1/4 Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Bore size (mm) Item 20 25 32 40 50 63 Size Suction flow rate L/min (ANR) 20/25/32/40 50/63 1.5
P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to
26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5
mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
75 100 125 150 175 200 300 500 25 50 75 100 250 400 12 20 32 40 50 63 12 equivalent 25 to 150 1 to 150 20 equivalent 25 to 300 1 to 300 Strokes other than standard strokes are available upon request.
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
50 63 14 14 14 17 17 20 50 50 56 63 63 71 47 47 53 60 60 67 1/4 1/4 1/4 3/8 3/8 1/2 17 17 20 23 25 30 36 36 40 45 50 60 59 59 59 70 74 86 43 43 43 48 48 60 15 15 17 20 20 25 31 31 36 41 46 56 19 19 22 26 26 30 145 75 18 110 136 115 25 90 90 90 115 115 140 16 107 58 110 M14 x 1.5 65 Up to 1000 3 5 30 46 +0.084 0 +0.100 0 0.1 0.3 161 78 18 110 146 128 28 16 114 64 110 M14 x 1.5 75 Up to
, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11 Series CQS How to Order . 1 12 16 20 25 5, 10 Construction . 12 Solid state switch D-M9N, F9NV D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series CQSK How to Order . 1 12 16 5, 10, 15, 20, 25, 30 Construction . 17 20 25 5, 10, 15, 20, 25, 30 35, 40, 45, 50 Dimensions ...18 &19 Note
SU) S SF A AA YB effective depth YC 2 YA View (mm) AA A AU AV AW AX AY BA BB BC BD BE CA CB D DD DE DF DG FA FB FC FD H J JA JB Size 10 20 30 50 55.4 50 6.6 20 15.5 12 4 9.5 34.5 27.8 60 27 4.5 28.5 45h9 46h9 20H9 6 15H9 8 4 3 4.5 13 6.8 11 6.5 70.8 65 7.6 27.5 16 14 5 12 46 30 76 34 6 30.5 60h9 61h9 28H9 9 17H9 10 6 2.5 6.5 17 8.6 14 8.5 75.4 70 7.6 29 18.5 14 5 12 50 32 84 37 6.5 33.5 65h9
-75 MXF20-100 MXF20-75 MXF20-50 MXF20-30 0.12 MXF20-30 0.04 0.04 MXF20-50 0.08 MXF20-30 0.02 0.02 0.04 0 0 0 50 100 150 40 80 120 240 200 160 200 50 100 150 200 Load (N) Load (N) Load (N) 8-6-5 6 Series MXF Model Selection Model Selection Step Formula/Data Selection Example Operating Conditions 1 Cylinder: MXF20-50 Cushion: Rubber bumper Workpiece table mounting Mounting: Horizontal wall
MHKL2-16D MHS 50 50 MHC 40 40 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa MHT 30 30 0.5 MPa 0.5 MPa L L 0.4 MPa MHY 0.4 MPa 0.3 MPa 20 20 0.3 MPa MHW 10 10 0.2 MPa 0.2 MPa 0 0 MRHQ 10 20 30 40 50 60 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Misc.
MPa 0.2 MPa 0 0 MRHQ 10 20 30 40 50 60 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Misc.
MHR2-10/MDHR2-10 MHR2-20/MDHR2-20 50 60 Overhang distance H (mm) Overhang distance H (mm) 50 40 Pressure 0.2 MPa Pressure 0.2 MPa 40 30 30 0.3 MPa External grip 0.3 MPa 0.4 MPa 20 0.4 MPa 20 0.5 MPa 0.5 MPa 0.6 MPa 10 0.6 MPa 10 0 10 20 30 40 50 0 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-
50 0 10 20 30 40 50 Gripping point L Gripping point L mm Gripping point L mm MHS MRHQ16 MRHQ16 MHC Internal gripping 60 60 Pressure 0.2MPa MHT 50 50 Pressure 0.2MPa Overhang H mm Overhang H mm MHY 40 40 0.3MPa 0.3MPa 30 30 0.4MPa 0.4MPa 0.3MPa MHW 0.5MPa 0.5MPa 0.6MPa, 0.7MPa 0.4MPa 20 20 0.6MPa 0.5MPa MRHQ 10 10 Misc. 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping point
S 6 50, 100, 150, 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com "n" pcs. n 8 50, 100, 150, 200, 250, 300 12 50, 100, 150, 200, 250, 300, 350, 400 Auto switch type Nil Without auto switch Adjuster option Nil Rubber stopper B Shock absorber Metal stopper One
55 60 35 40 45 50 55 60 35 40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80 85 25 30 35 40 45 50 25 30 35 40 45 50 25 30 35 40 45 50 55 60 65 70 30 35 40 45 50 55 60 65 70 75 CQ-M3 x 35L x 40L x 45L x 50L x 55L x 60L CQ-M3 x 35L x 40L x 45L x 50L x 55L x 60L CQ-M5 x 35L x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L CQ-M5 x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L
+ 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation
30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002