SMC Corporation of America
Elite Part Number Search
Search Results "CLA2B100TN-500-P"

= (P P) MPa Viewing the graph To generate a water flow of 4l/min at a differential pressure of 0.1MPa, an effective area with Cv factor 0.28 (VDW303) or more is required.

With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke * Refer to p.3.8-10 for minimum strokes for auto switch equipped style. Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.

500, 600, 700, 800 Oversized rod cylinder XB5 125 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (150C) XB6 Intermediate strokes are available.

Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 25 mA or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short

V: Power supply voltage Power consumption P: 20 [kW] Q = P = 20 [kW] P Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = 24 [kW] Power consumption w Derive the heat generation amount from the power e Derive the heat generation amount from the output. supply output. Output (shaft power etc.)

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

(A) 2 23 (AR) (A) 2 Refer to Best Pneumatics No. 1 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Regulator Series AR Model Specifications Model AR20 Port size 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 AR40 AR20 AR25 AR30 AR40 Model Proof pressure 1.5 MPa 1.0 MPa 0.05 to 0.85 MPa 1/4, 3/8, 1/2 Max. operating pressure Pressure gauge port size 1/8 1/4 Set pressure range Ambient and 5 to 60C (No freezing

Positive pressure) 0.000 to 1.000 MPa 0.100 to 1.000 MPa 1.5 MPa 0.001 0.01 0.01 0.1 Rated pressure range Operating pressure range and regulating pressure range Proof pressure kPa MPa kgf/cm2 Note 1) Setting/Display resolution ZSE ISE bar psi mmHg inHg PSE Z I SE3 Fluid that will not corrode stainless steel 630 and 304 12 to 24 VDC, Ripple (p-p) 10% or less 55 mA or less (With no load)

Please refer to P.125. Specifications AP3200 Normally closed (N.C.)

RSH20, 32 Graphq Graphw 1.0 RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] 0.8 1300 1300 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 600 600 0 500 100 200 300 400 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63,

Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.

0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 1 to 10 L/min 50 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 0 to 0.5 L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 1 to 1 L/min 3 to 3 L/min 5 to 500 L/min 2 to 200 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 1000 L/min 10 to 100 L/min 300 to 6000 L/min 20 to 2000 L/min 20 to 200 L/min 600 to 12000 L/min 24 VDC 10% 12 to

P-80 (D) This catalog is printed on recycled paper with concern for the global environment.

Contaminant concentration of used fluid: 500 ppm (initial concentration, percentage by volume) 4. Number of separators: 2 pcs. (applicable fluid storage volume of 100 L/unit) Based on the elimination ratio data for the FHM-100 and the point where the 500 ppm line and flow-back count 30 line intersect (one hour after starting operation), the result is 75%.

With end lock (R) Functional option Axial piping type (P) For detailed specifications of adjuster options and functional options, refer to option specifications on pages 3 and 4. Standard Strokes Order Made Order Made Specifications Model Standard stroke (mm) For order made specifications of series MXQ, refer to page 42.

Timing of Wireless Communication 20 / 40 / 100/ 200 / 500 / 1,000 / 2,000 / 5,000 msec 500 msec Activated only when protocol V.2.0 is used If wireless communication (including retries) does not succeed due to obstacles or for other reasons, it is judged to have failed after a set amount of time and disconnected. Afterwards, the Base and the Remote are reconnected.

40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600

40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600

P (Port size) Operation P (Port size) Model CYV15 CYV32 Caution 5/16-24 UNF 7/16-20 UNF 1. The maximum operating pressure for the vacuum rodless cylinder is 0.3 MPa.

off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance work Otherwise an injury can result. [ 500] 500 L/min (PF3A701H) [ P] Select input switch operation The accumulated flow has exceeded the accumulated flow range.