SMC Corporation of America
Elite Part Number Search
Search Results "CNA2F40-50-D"

10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.

D-F7BAL D-F79F D-F7LF D-F7NTL D-F79 D-F7P D-J79 D-F79W D-F7PW D-A72H D-A73H D-A76H D-A80H 32, 40 (mm) D-A72H D-A73H D-A76H D-F79W D-F7PW D-J79W D-F7NTL D-F7BAL D-F79F D-F7LF D-A80H D-F79 D-F7P D-J79 Auto switch model A B Hs A B Hs A B Hs A B Hs Symbol Standard stroke 32 40 9.5 13.5 6.5 9 32.5 36 9.5 13.5 10.5 13 32.5 36 14.5 18.5 10.5 13 32.5 36 6.5 9 32.5 36 13.5 17.5 Bore size (mm) Long

B A (mm) Applicable auto switch D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV D-F79F Other than the models listed in How to Order, the following auto switches are applicable. For detailed specifications, refer to page 1627.

54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16

U A 38.2 Auto switch mounting positions Auto switch mounting height (mm) D-C7 D-C8 D-H7 D-H7W D-H7F D-H7BAL U D-C7 D-C8 D-C73C D-C80 Auto switch model D-H7W D-H7F D-H7BAL D-H7 D-H7C D-C73C D-C80C D-H7C Bore size (mm) A B A B A B U U 40 22.0 26.0 21.0 25.0 19.5 23.5 35.0 38.0 37.5 50 30.0 18 29.0 17.0 27.5 15.5 40.5 43.5 43.0 26 Series RSDG Auto Switch Internal Circuits Lead wire colors inside

D-F9NV, D-F9PV, D-F9BV 6.8 MDHR2-30 Unit: mm D-F9P, D-F9B D-F9N Auto switch Air gripper model no. The auto switch will not protrude in the case of D-F9N, D-F9P, D-F9B.

(n 2) 2 D-C7 D-C80 D-H7C D-C73C D-C80C D-G5/K59 D-G5W/K59W D-G59F/G5BA/G5NT D-B5/B64 50 + 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is

78.5 OUT 10 4 46.2 33.0 19.8 66.0 IN 141 101 60.3 201 OUT 16 6 121 86.0 51.6 172 IN 220 157 94.2 314 OUT 20 8 185 132 79.2 264 IN Minimum Stroke for Auto Switch Mounting (mm) Applicable auto switch model No. of auto switches mounted D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV 1 pc. 5 5 5 2 pcs. 10 5 10 Weight (g) Stroke (mm) Model 5 10 15 20 25 30 40 50 60 MXH6 MXH10 MXH16 MXH20 62 67 76 81 91 96

(different sides) 25 Auto Switches/Proper Mounting Position for Stroke End Detection D-Z7, Z80 D-Y59, Y69, Y7P D-Y7NW, Y7PW, Y7BW D-Y7BAL A 0 to 1 A B Bore size (mm) B 40 0 23 50 0 23 63 0 32 1in = 25.4mm Auto Switch Mounting Flat head watchmakers screw driver When mounting an auto switch, first hold the switch spacer between your fingers and press it into the groove.

ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 For 2 stations manifold 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold d Models and Dimensions D Symbol Applicable size d A L D Weight [g] Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4" 18 35 8.5 1 Orange 09 5/16" 20.5 39 10 2 Orange Connector type 1 D sub-connector (25

VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Electrical entry: D or DZ only Electrical entry: D or DZ only Coil rated voltage 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 1) Manual override 5 6 Note 1) Non-locking push type Nil A Electrical entry CE-compliant G Non-locking push type

50% 5% ON OFF [F 2] OUT2 36 ON OFF 50% 5% OUT1 ON OFF 50 5 -26No.PF-OMM0004-D / [F3] 42 1 [F10] 43 [F20] 47 [F22] 48 OFF [F30] 50 OFF[] [F80] 51 [] [F81] 52 OFF [F82] 53 [*] [F90] 54 OFF [F98] 55 OFF [F99] 56 OFF 30 [F10](43 ) (4 L/min ) OUT2 -27No.PF-OMM0004-D [F 1] OUT1 OUT1 1.

D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,

Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 118"(3m)) Internal resistance D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 13 Series VQZ How To Order Manifold Connector Kit Preferred Option Program How To Order: VQZ100 Base Mounted Manifold VV3QZ 1 5 08 N7T C Option Series None DIN rail mounting (DIN rail standard length) External pilot 1 VQZ100 D R Manifold type 5 Base mounted Kit C Connector Number

C Locking type (Manual) VK 1 100 VAC, 50/60 Hz Electrical entry 2 200 VAC, 50/60 Hz 3110 VAC, 50/60 Hz 4220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC VZ L: L plug connector, With lead wire LN: L plug connector, Without lead wire LO: L plug connector, Without connector D: DIN terminal G: Grommet, Lead wire length 300 mm Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

CM2 CG1 MB How to Order MB1 NC D A1 B 150 0400 A XC8 CA2 Bore size Adjustment range A: 0 to 1" B: 0 to 2" Auto switch CS1 Mounting C76 Stroke Adjustable strokeExtend C85 C95 Dimensions CP95 P + Stroke d + Stroke + Adjustable range LD + Stroke NCM 4-DD D across flats 2-EE (NPTF) c + Adjustable range Stroke NCA AA D-X 20Depth ND 4-NT Data SN + Stroke ZZ + 2 stroke + Adjustable range (A: 1",