MTS Leakage [Pam3/sec] 10-8 MY Note 2) The leakage test result shown is based on a test conducted for 10 minutes after the cylinder was pressurized with helium at 0.1 MPa. CY Note 3) This data is considered typical but not guaranteed. 10-9 MG Leakage test result CX 10-10 0 5 10 DTime [min] -X e e a a l l k k w w a a 2 o o g g 1 O-ring seals separate vacuum and atmosphere.
10-10 0 5 10 t i o o n L DTime [min] Operation cycles -X e e a a l l k k a t e l u w w g a a c 2 e i o o g g 1 O-ring seals separate vacuum and atmosphere. t Employs a magnetically coupled rodless cylinder with no air leakage from moving parts. n 1 r a L L e e e Particulate generation from the linear guide unit has been reduced with the use of a stainless steel linear guide and low particulate
Nut Replacement Parts: Seal Kit (A rod seal @7, a piston seal @8 and a tube gasket @9 are included in the seal kits. Order the seal kits with ordering numbers.) Kit no.
Make sure to connect a speed controller and adjust it to a speed of 500 mm/s or less to operate the cylinder.
Make sure to connect a speed controller and adjust it to a speed of 500 mm/s or less to operate the cylinder.
Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs)
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
As a reference, the tightening torque is 1 to 1.5 Nm. (When replacing the piping adapter ZS-46-N#, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm.
17 18.6 20.8 M L Q A D N M O L Q A Note 1) D is maximum diameter.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
ANm0m0-KMmm 5.2-4 40dB(A): High Noise Reduction Silencer Series ANA1 A high noice reduction style silencer keeps the noise level inside a plant below 85dB(A).
3 O-ring NBR u 15-9-105 Dimensions L4 D3 H (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 A 8 9 9 4.5 10 31 10.3 0.7 27.4 AS220-N01-ST NPT 1/8 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 R 1/8 12 14.3 14.6 7 18 35.6
Able to control and set a constant speed easily.
Due to the compressibility of air as a fluid, the actuator will continue to move until it reaches a position of pressure balance, even though the pilot check valve closes with an intermediate stop signal. 2. This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage.