EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.

EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.

Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.

K T 2 X NPN 2 Y PNP 2 A1 A R NPN 2 + 1 () T PNP 2 + 1 A2 B S NPN 2 + 1 V PNP 2 + 1 1 B D + M SI 3 P psi 2 2: 3kPaMPa 1 ( 2m, ) W M5 M5 01 R1/8 N01 NPT1/8 C4L 4mm C6L 6mm -8No.PS-OMU0005CN-C / A ZS-46-A1 38L (2 ) B ZS-46-A2 38L (2 ) ZS-46-B + ZS-46-D ZS-46-5F 5 2 m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4L 6mm ZS-46-C6L -9No.PS-OMU0005CN-C OUT1 LCD OUT2

KF 45' Female Elbow Y M a l e R u n T e e . . . . . T Male Branch Tee . , T Union Tee , . . . . . . , TF Female Branch Tee E Bulkhead Connector E Bulkhead Union . . , U Male Branch 'Y" . . . U Union "Y" . . . . . . . .

Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006

L-bracket IZN10-B1 Pivoting bracket IZN10-B2 Power supply cable length Symbol Type 01 1 m 20 20 m * Available in 1 m increments from 1 m to 20 m.

KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8

CYRZ-V CYRZ-W CYRZ-X CYRZ-Y 12REA Warning 1. Do not disassemble the product because it may damage the air cushion mechanism.

Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output

Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output

Z directions, 2 hours each 490m/s in X, Y, Z directions, 3 times each 290g (without lead wire) 250g (without lead wire) Equivalent to IP65 3/8 1/2 1/8, 1/4 Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min or l).]

OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Symbol Nil S Material Brass Stainless steel D side U side 1 2 3 4 5 n 02 : 10 2 stations : 10 stations All IN ports are 3/8. Refer to the L dimension table on page 7 regarding the maximum number of stations.

y conncector, SY3000 SOL/VALVE, RUBBER SEAL*** $7.79 + Add to Quote Add To Cart Add to Cart SMC SY100-82-2-03 y conncector, SY3000 SOL/VALVE, RUBBER SEAL*** $8.84 +

Inlet pressure (MPa) Weather resistant NBR Diaphragm assembly e 1315510A Flow Characteristics Inlet pressure: 0.7 MPa Valve assembly Valve spring Valve mini Y packing O-ring O-ring Handle Set nut Brass, HNBR Stainless steel NBR NBR NBR Polyacetal Zinc die-casted r t y u i o !

OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Symbol Nil S Material Brass Stainless steel D side U side 1 2 3 4 5 n 02 : 10 2 stations : 10 stations All IN ports are 3/8. Refer to the L dimension table on page 7 regarding the maximum number of stations.

Note Bracket VK300-43-2A With screw Body ported VK3120 1 G M5 VK3140 1 G 01 Base mounted Thread type Nil F N T Rc G Valve option Port size NPT Nil Standard For low wattage (2 W DC) 01 Rc (With sub-plate) Nil Without sub-plate 1 8 NPTF Y Option Light/Surge voltage suppressor Nil None S With surge voltage suppressor Z With light/surge voltage suppressor (Type D only) Since the indicator