ZSE10 ISE10 Reducing setting labor Minimizing risk of mistakes in setting ISE70 Copy Copy ZSE80 ISE80 PS ISA3 ISA2 ISE35 Master sensor 1 unit Slave side 2 units 10 units PSE 3-step setting 3-step setting IS ISG 1 2 3 ZSM1 Push Push Push Push Completion of setting Adjust to the set-value by the or button. Added vacuum range.
1 5 Port Air Operated Valve Series SYA3000/5000/7000 How to Order SA One-touch fitting (Inch size) A, B port size Thread type VA Thread piping Nil Rc Symbol Port size Applicable series M5 01 02 Symbol Port size Applicable series N3 N7 N3 N7 N9 N7 N9 G F SA 5 32" SYA3000 SYA5000 SYA7000 One-touch fitting for M5 x 0.8 N NPT SYA3000 1 4" 1 8 1 4 One-touch fitting for NPTF T VA 5 32" One-touch
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
[mm] Bore size A B C D F GA GB H LB LC LH LT LX LY LZ MM NA NB NC NN S SA T X Y Z ZA 6 15 12 14 3 8 14.5 5 28 15 4.5 9 1.6 24 16.5 32 M3 x 0.5 16 9.5 7 M6 x 1.0 51.5 49 3 5 7 79.5 77 10 15 12 14 4 8 8 5 28 15 4.5 9 1.6 24 16.5 32 M4 x 0.7 12.5 9.5 M8 x 1.0 46 5 7 74 16 15 18.3 20 5 8 8 5 28 23 5.5 14 2.3 33 25 42 M5 x 0.8 12.5 9.5 M10 x 1.0 47 6 9 75 52 Air Cylinder: Standard Type
3 Stainless steel y POM u POM 5-6-42 5 Port Mechanical Valve Series VZM500 Series VZM500 Basic VZM550-01-00 Accessory mounting hole (Pilot exhaust port) SA JIS Symbol VA SA VA 0.5 MPa supply VM 1.0 mm P.T. 16 N F.O.F. VR 2-3.2 mounting hole 2.0 mm O.T. 3.0 mm T.T.
One Way Roller Lever/VFM350-02-02, VFM350-02-02S JIS Symbol 7N F.O.F. 0.5MPa supply 2.4mm P.T. 4.6mm O.T. 7mm T.T. 3.5-49 VFM300 Series VFM300 Straight Plunger/VFM350-02-05 Panel mounted hole SA JIS Symbol VA SA VA 20N F.O.F. 0.5MPa supply 1.5mm P.T. 2mm O.T. VM/VR 3.5mm T.T.
1 4/5 Port Air Operated Valve Series SYJA3000 How to Order SA VA Bracket With bracket F Nil Without bracket SA SYJA3 20 1 M3 Body ported VA VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Base mounted (4 port) VR (Manifold use only) SYJA3 30 2 VH VHS Base mounted
SA VA SA VA VM Environment Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Caution Selection VR 1. When the valve is exposed to a large amount of dust, install a silencer into the port 3(R).
(mm) Bore size A1 82 85 MM M6 x 1.0 M8 x 1.25 20 25 B1 10 13 C1 10 12 H1 3.6 5 K 5 5 KA 6 8 L1 22 24 X 12 14 (mm) Bore size A 70 71 H M4 x 0.7 M5 x 0.8 20 25 B 60 61 C 8 10 D 8 10 E 33 40 F 6 6 I 42 50 K 5 5 KA 6 8 L 10 10 M 22 26 N 4.4 5.4 OA M5 x 0.8 M6 x 1.0 Q 14 14 R 10 10 SA 6.5 6.5 SB 10.5 11 Stroke range 50 or less 50 or less Note 1) The [ ] value denotes dimensions with the auto
Hand Valve Series VH Specifications SA Fluid Air VA Proof pressure 1.5 MPa SA Max. operating pressure VH200/300/400 1.0 MPa VH600 0.7 MPa VA Ambient temperature and operating fluid temperature 5 to 60C (No freezing) Operating angle 90 VM Lubrication Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
1 5 Port Air Operated Valve Series VFA3000 How to Order SA Thread type (Including pilot port) VA Nil F N T Rc G NPT NPTF SA Port size (P, A, B port) VA 01 02 1 8 1 4 Option R1, R2 port are 1/8.
, ISE70/75 1/4" PT VERSION, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.46297 lb
1 5 Port Air Operated Valve Series VZA2000 Specifications SA Fluid Air VA Operating pressure range (MPa) 0.1 to 1.0 VZA2121, 2141 2 3 4 2 3 4 VZA2 21, 2 41 0 to 1.0 SA Pilot pressure range (MPa) 0.1 to 1.0 Impact/Vibration resistance (m/s2) 150/50 Note) Base mounted VA Operating pressure Pilot pressure Note) Impact resistance: No malfunction from test using drop impact tester, to axis and
apply onty to a ct6rn, sa tub crt6d vatve, DESIGN Thls dsslgn conospt constsls of a Match.cround .:SPOOL & SLEEVE,, assembly which controls the main valving functions.
+ Stroke AO E AO (in) G DD F AH J R A AB AA EA C B AL S KK D BA SA XA AE Bore (in) WF Y E P ZA EE LF AO MM AT 1.26 1/4-28 3/8 1 3/16 1.43 1.1 3/4 3/8 2.02 0.3 3/8 1 1/8 1 1 1/4 7/16-20 9/16 1 1/8 5 5/8 6 2 3/16 150 (1.5") 1 1.71 2 2.36 6 1/16 3/8 3 5/8 7/16 5/8 1/8 1.26 5/16-24 3/8 1 7/16 1.84 1.06 3/4 3/8 2.6 0.3 3/8 1 1/8 1 1 3/4 7/16-20 9/16 1 1/8 5 5/8 6 2 11/16 200 (2") 1.71 1 2 1/2
3 Stainless steel y POM u POM 5-6-42 5 Port Mechanical Valve Series VZM500 Series VZM500 Basic VZM550-01-00 Accessory mounting hole (Pilot exhaust port) SA JIS Symbol VA SA VA 0.5 MPa supply VM 1.0 mm P.T. 16 N F.O.F. VR 2-3.2 mounting hole 2.0 mm O.T. 3.0 mm T.T.
32 40 50 62 17 18 25 30 38 48 3 4 6 8 10 12 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 7 7 7 9 10 11 M3 x 0.5 depth 5 M3 x 0.5 depth 5 M4 x 0.7 depth 6 M5 x 0.8 depth 8 M5 x 0.8 depth 8 M6 x 1.0 depth 9 3.2 3.2 4.5 5.5 5.5 6.6 12.5 14 18 22 5 6 8 10 4 9 9 13.5 2 4.5 4.5 4.5 19 21.5 23 Note) 5 stroke (CUW16-5D): GA = 14.5 Without auto switch With auto switch Bore size (mm) R SA
Piping: NPT1/4, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: -, Option 1: -, Option 2: -
Piping: NPT1/4, Output: 27 [NPN Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: -, Option 1: -, Option 2: -