Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PNP DC STEP MOTOR CONTROLLER, ELECTRIC ACTUATOR, A02, 0.1615 lb
LINEAR GUIDE SINGLE AXIS SLIDER ACTUATOR, ELECTRIC ACTUATOR, A22, 3.315 lb
Linear Guide Single Axis Slider, ELECTRIC ACTUATOR, 3.28 lb
Linear Guide Single Axis Slider, ELECTRIC ACTUATOR, 3.28 lb
-125, BS5-160 BS5-180, BS5-200 When D-F5BA auto switch is shipped mounted on a cylinder, the above stainless steel screws are used.
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 Available Available (40 to 63) 20 25 32 40 50 63 80 100 100 Non-lube Double acting, Available double rod 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Suction flow rate of vacuum suction type (Reference values) Specifications Bore size (mm) Item 20/25/32/40/50
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Refer to page Best Pneumatics Vol. 6. 0.07 0.07 0.07 0.20 Double knuckle joint (With pin) MVGQ Calculation: (Example) REC32-200 Basic weight 0.90 (kg)(Foot style 32) Additional Weight 0.09 (kg/50 st) Cylinder stroke 200 (st) 0.90 + 0.09 x 200 50 = 1.26 kg CC RB Auto Switch Mounting Bracket Part No.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Set point 0.5 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate (L/min (ANR)) Supply pressure P1 (MPa) Relief flow rate (L/min (ANR)) 817 IR1000/2000/3000 Series IR3000 Series The operating conditions or external disturbance may affect each of the characteristics.
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
Air purge: Yes (0.1 MPa) 8 90 Discharge time from 1000 V to 100 V 7 60 6 Catalog specification value: 30 V Discharge time (s) Offset voltage (V) 30 5 0 4 Without sensor 3 30 2 With feedback sensor 60 1 90 0 100 200 300 400 500 0 0 100 200 300 400 500 Installation height of feedback sensor (mm) Installation height of feedback sensor (mm) Ionizer 600 mm Feedback sensor Installation height of
dimensions 055 55 x t20 100 200 100 x t30 200 x 140 x t40 Magnetic separator Magnetic separator Fluid Iron Content Elimination Performance by Iron Particle Concentration FHMN-055 FHM-100 FHM-200 Fluid: Hydraulic fluid Fluid: Hydraulic fluid Fluid: Hydraulic fluid 100 90 80 70 60 50 40 30 20 10 0 1 5 10 50 100 100 90 80 100 90 80 70 60 50 40 30 20 10 0 100 200 300 400 500 100 200 300 400 500
Flow rate [L/min (ANR)] 0 50 100 Flow rate [L/min (ANR)] AFM30-D AFD30-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa 0.01 0.01 P1 = 0.7 MPa P1 = 0.7 MPa 0 0 0 100 200 500 400 300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 =
Heating capacity [W] 600 600 Heating capacity [W] 40 40 32 32 25 25 400 400 5 5 200 200 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-12 Heating capacity (HRR012-A/W-20,HRR018-A/W-20) 9.5.3 HRR024-A/W-20,HRR030-A/W-20 Ambient temp. 800 800 or Ambient temp.
Cylinder stroke (mm) Long stroke (mm) 35, 40, 45, 50, 75, 100 Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30 Action D Double acting 12, 16 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switch.
0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 200 400 600 800 1000 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 6 Series IR1000/2000/3000 Series IR3000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.
300 400 500 280 560 Data 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load weight W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average speed Va mm/s 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Note) Use the average speed when calculating static moment.