SMC Corporation of America
Elite Part Number Search
Search Results "LVM11-5A-1"

Symbol: Body Ported, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: None, Bracket: Bracket, Lead Wire Length: -, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ2.8, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Body Ported Type, Voltage: 24 V DC, Option: Bracket, Power Consumption(W): Inrush: 2.5 / Holding: 1,

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ2.8, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Body Ported

Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ2.8, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Body Ported Type, Voltage: 24 V DC, Option: Bracket, Power Consumption(W): Inrush: 2.5 / Holding: 1,

Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 6 (600mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 6 (600mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)