typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated flow rangeLinearity Note 3)RepeatabilityPressure characteristicsTemperature characteristicsOutput specificationsResponse timeHysteresisPower supply voltageCurrent consumptionResistanceWeightPort size (Rc, NPT, G)PF2A706HDry air, NitrogenHeater type300 to 6000
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 150 (1 1/2"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: NCA1 (Standard), Mounting: X (MP1, Double Rear Clevis), Bore Size: 150 (1 1/2"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: IM (Intermediate Male, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Size: 5 (3/4 Standard), Auto Drain: 1 (Auto Drain N.O.), Thread: Rc(PT), Port Size: 06 (3/4 - AMR5000/6000), Switch: w/o Switch, Adaptor: None, Symbol: R (Flow direction: right to left)
Bore sizes: 25, 32, 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 4000 mm (25 & 32 bore), 5000 mm (40 bore), 6000 mm (50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Applicable fluids: Air, Nitrogen; Flow ranges: 30-3000, 60-6000, and 120-12000 liters/min; Rated Pressure: 0.1 to 1.5 MPa; Accuracy: +/-3.0% F. S.; Accumulated flow to 999,999,999,990 L
Applicable fluids: Air, Nitrogen; Flow ranges: 30-3000, 60-6000, and 120-12000 liters/min; Rated pressure: 0.1 to 1.5 MPa; Output options: IO-Link, NPN/PNP switch, 1-5V, 0-10V, 4-20mA; Accuracy:±-3.0% F.S.; Repeatabililty: ±-1.0% F.S.; Accumulated flow to 999,999,999,990 L
Inlet pressure: max. 6000 psig (41.4 MPa); Delivery pressure: max. 2500 psig (17.2 MPa); Body material: stainless steel or brass; Self relieving or non-relieving available; Piston sensing element
Series: NCA1 (Standard), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 6000 (60")
Series: NCA1 (Standard), Mounting: U (MT1, Rod Trunnion), Bore Size: 325 (3 1/4"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: NCDA1 (Standard w/ Magnet), Mounting: B (MX0, Basic), Bore Size: 325 (3 1/4"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Applicable fluids: Air, Nitrogen; Flow ranges: 30-3000, 60-6000, and 120-12000 liters/min; Rated Pressure: 0.1 to 1.5 MPa; Accuracy: +/-3.0% F. S.; Accumulated flow to 999,999,999,990 L
Applicable fluids: Air, Nitrogen; Flow ranges: 30-3000, 60-6000, and 120-12000 liters/min; Rated pressure: 0.1 to 1.5 MPa; Output options: IO-Link, NPN/PNP switch, 1-5V, 0-10V, 4-20mA; Accuracy:±-3.0% F.S.; Repeatabililty: ±-1.0% F.S.; Accumulated flow to 999,999,999,990 L
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch, high flow rate ; Integrated display type ; Port size: 1", 1 ½", 2" ; NPN or PNP open collector, 1 output + analog ; Flow rate (l/min): 150~3000, 300~6000, 600~12000
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)
Series: NCDA1 (Standard w/ Magnet), Mounting: L (MS1, Foot), Bore Size: 400 (4"), Stroke: 6000 (60")
Delivery Pressure: I [10 to 1000 psig (0.07 to 6.9 MPa)], Relieving: 1 (Self Relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 8 (NPT 1/2 Inch), Gauge Port, Inlet: 60 [6000 psig/bar (41 MPa), Gauge Port, Outlet: 10 (1000 psig/bar (7 MPa), Pressure Gauge Unit: psig/bar, Option: Standard (Cv: 0.8), Installation Option: P (Panel Installation)
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 6 [600 psig (4.1 MPa)], Gauge Port, Outlet: 0 (No Pressure Gauge), Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: Viton®,
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 0 (No Pressure Gauge), Gauge Port, Outlet: 0 (No Pressure Gauge), Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: Viton®,