Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B (Basic), Size: 40 (Equiv. Ø40 Piston Area), Port Thread Type: M thread: ø25, Rc: 32 to 63, Stroke: 20mm, Action: T (Single Acting, Spring Extend), Rod End: M (Male Thread), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SBPC

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Port

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 50mm, Stroke: 20mm, Action: T (Single Acting, Spring Extend), Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Stroke: 20mm, Action: Single Acting, Spring Extend, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without

Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.

to 63 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV U D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-J7V D-F7BAV 12 to 20 U B A 32 to 63 B A U 664 Auto Switch Mounting CE1 Series Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) Auto switch model D-A73

Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7NF A72H A73H F79 F7P J79 F79W F7PW J79W F79F Lead wire length symbols: A72 A73

Lead wire length (m) Load voltage Auto switch model Indicator light Wiring (Output) Special function Type Electrical entry Pre-wire connector Rail mounting Band mounting Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet C73 C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7NF A72 A73

Bore size (mm) D-A73/A80 D-F7NT Electrical entry (Fetching direction) Type Model Features D-F7NT Solid state auto switch Grommet (In-line) With timer A B A B A B With pre-wired connector is available for D-F7NT type, too.

Model: MRQBS32-50CA-A73 Operating pressure: 0.5 MPa MSU CRJ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CRA1 Calculate the amount of air requirement for A, B, C and D respectively.