ZP 18 4 15.5 ZCU 4.5 Bracket A (Standard accessory) AMJ Note 2) Dimensions : For mounting bracket A : For mounting spacer 1.
Compared to a circuit with only meter-in control, more stable low speed actuation is possible. Vertical actuation I II P W A P a (b) (a) P P a A W (1) Basically adjusted with meter-out control. When meter-in control is also used, lurching is reduced. (1) Basically adjusted with meter-out control.
: (800) 258-9200-www.stevenengineering.com 6 1 2 Analog output (43.5) ZSP 8 4 Load 2 + Switch output White 7 3 4 ISA2 Black 5 1 3 Blue IS A PF2W5--1 ZSM 4 Output specifications A B PF2 Display unit (PF2W30/31) Pulse output only 42 62 12 to 24 VDC Sensor unit Pulse output + Analog output 52 72 2-3.4 43 Brown IF 1 2 6 Analog output Flow direction 4 8 Load 2 Data + Switch output White 4 3
1 2 3 4 7 3 Load +0.5 0 Brown 19.4 6 2 + 36 Blue 5 1 12 to 24VDC 5 6 7 8 Series PF2W5 PF2W31-A The applicable panel thickness is 1 to 3.2mm.
[Cracking pressure] This is the pressure at which a check valve first opens and achieves a given flow rate as pressure increase. [Ultimate vacuum] The maximum vacuum generated by a vacuum generator. [slpm] Abbreviation for standard liter per minute. Indicates the volumetric flow in liters per minute of time at standard conditions of a temperature of 0C and a pressure of 1 atmosphere.
S07B5 4(A) 2(B) 5(R1) 3(R2) 1(P) 5 (R1) 4 (A) 1 (P) 2 (B) 3 (R2) y t N.O. + N.O. Component Parts S07C5 2(B) No.
(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.
Table: OR Logic Table I I I I O 1 1 1 1 1 1 1 1 0 1 1 1 0 0 1 1 0 0 0 1 0 0 0 0 0 5 1 PneuAlpha The Logic Function Blocks 5 5.3 The NOT Block The NOT block takes a signal and inverts it an Input that is On has an Output that is Off, and vice versa. The Output comes ON when the input is OFF. The Output is OFF when the input is ON. If no Input pin is used, the block output is OFF.
4 (B) 2 (A) 4 (B) 2 5 (EA) 3 (EB) 1 (P) 5(EA) 3(EB) 1(P) JIS symbol 2 position double 2 position double (A) 4 (B) 2 (A) 4 (B) 2 5 (EA) 3 (EB) 1 (P) 5(EA) 3(EB) 1(P) JIS symbol 3 position closed center 3 position closed center/exhaust center/pressure center (A) 4 (B) 2 (A) 4 (B) 2 5 (EA) 3 (EB) 1 (P) 3 position exhaust center (A) 4 (B) 2 5 (EA) 3 (EB) 1 (P) 3 position pressure center (A)
Modular Type Regulator AR Series AC-A Regulator AR Series AF-A Model Port size Options AF-A AR10-A M5 x 0.8 AR-A AR-A AL-A AR20-A 1/8, 1/4 AW-A Bracket AC-B AF-A AR25-A AF-A 1/4, 3/8 Round type pressure gauge AR -A -B AR30-A AL-A Set nut (for panel mount)* AW -A -B AR40-A 1/4, 3/8, 1/2 AW AG AR40-06-A 3/4 * For AR20-A to AR40-06-A, panel fitting dimensions are different from those of the
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
32UNC #8-32UNC #10-32UNF 1/4-28UNF 8 8 8 9.5 6.8 6.8 6.9 8.1 11.5 11.5 12.5 14.5 Basic A B A B Without auto switch With auto switch (All dimensions are common expect "A" and "B".)
SMC FLOW SWITCH Blue 5 1 12 to 24VDC Series PF2W5 35.8 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 8-M3 3 x 7.2 (= 21.6) 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 7 3 Load +0.5 0 Brown 19.4 6 2 + 36 Blue 5 1 12 to 24VDC 5 6 7 8 Series PF2W5 PF2W31-A The applicable panel thickness is 1 to 3.2mm.
(or within 3 kPa ) 1/8 ARP ARP 1/4 For 0.2 MPa setting With backflow function (ARP20K/30K/40K) 3/8 IR-A 1/2 Installable between a solenoid valve and a cylinder : Standard : Semi-standard IR Direct operated precision regulator now available as a series!! (ARP20/30/40) IRV VEX SRH Applications Applications SRP a Apply a constant pressure to fluid. b Adjust the blow-line pressure.
After tightening by hand, tighten an additional 1/4 rotation for M3 and 1/6 rotation for M5 with a tool. However, when using a miniature fitting, tighten an additional 1/4 rotation with a tool after tightening by hand. Also, when there are 2 gaskets such as in case of a universal elbow or universal tee, tighten an additional 1/2 rotation.
Electrical Connections Caution Grommet/Conduit AWG18 Lead wire color Rated voltage 2 Blue Red Gray 1 Blue Red Gray 1 2 100VAC 200VAC Other AC Conduit terminal In the case of the conduit terminal, make connections according to the marks shown below. Terminal cover A Round head combination screw M3 Caution 2 1 + mark + mark A 1. Filters and strainers 1.
(or within 3 kPa ) 1/8 ARP ARP 1/4 For 0.2 MPa setting With backflow function (ARP20K/30K/40K) 3/8 IR 1/2 Installable between a solenoid valve and a cylinder : Standard : Semi-standard IRV Direct operated precision regulator now available as a series!! (ARP20/30/40) VEX SRH SRP Applications Applications SRF a Apply a constant pressure to fluid. b Adjust the blow-line pressure.
OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact SMC regarding other voltages.