SMC Corporation of America
Elite Part Number Search
Search Results "RDLQA40-30-B"

Round plate (Including column) Position of rotational axis: Through the center axis (B) Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teethb 5.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 16.5 16.5 A 22 B A 24.5 B A and B are the dimensions from the end of the head cover/ rod cover to the end of the auto switch. A and B are the dimensions from the end of the head cover/ rod cover to the end of the auto switch.

center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.

Description Material ARM1000 ARM2000 134819-30 13615 13614 16.5 x 13.5 x 1.5 JIS B 2401P7 (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 10 /min (ANR) VY1 13626-30 13625 13624 23 x 20 x 1.5 JIS B 2401P8 Valve Valve spring Valve guide O-ring O-ring Brass, HNBR Stainless steel Polyacetal NBR NBR u i o !0 !

Description Material ARM1000 ARM2000 134819-30 13615 13614 16.5 x 13.5 x 1.5 JIS B 2401P7 (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 10 /min (ANR) VY1 13626-30 13625 13624 23 x 20 x 1.5 JIS B 2401P8 Valve Valve spring Valve guide O-ring O-ring Brass, HNBR Stainless steel Polyacetal NBR NBR u i o !0 !

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

A 13 15 22 06 08 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 End bracket/IZS40-BE 35 22 4.5 30 18 2 x 5.4 105 33 L 33 Intermediate bracket/IZS40-BM 55 35 22 4.5 36 30 18 2 x 5.4 A 105 33 A A-A section 431 IZS40/41/42 Series Dimensions Ionizer/IZS41, 42 30 44 304 6.8 30 85 9 60 50 A 60 x (n-1) L n (Number of emitter cartridges), L Dimension L (mm) IZS4-340 IZS4-400 IZS4-460 IZS4

NS 14 14 24 24 30 30 45 55 60 LT 42 42 52 52 62 62 72 82 92 LB 20 25 30 LA 10 10 20 20 30 30 20 25 30 J 4 4 4 4 4 4 6 6 6 Stroke (mm) 5 10 15 20 25 30 40 50 60 24 Compact Slide MXH Series Dimensions: 10 LT MXH MXH 19 11 MXS MXQ 11 LA LB J x M4 x 0.7 Depth 6 MXQ 3 x M5 x 0.8 through Pilot hole dia 4.3 2 x 3 x 7.5 counterbore depth 4.4 MXF 2 x 2 x M5 x 0.8 Cylinder port (With plug for port)

Description B VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Bracket (with bolt and washer) 4.2-30 VNH Specifications 3 port valve 2 port valve A B A B VNH311 20A A B VNH411 25A A B VNH113 10A A B VNH213 15A A B VNH313 20A A B VNH413 25A A B VNH133 10A A B VNH233 15A A B VNH333 20A A B VNH433 25A A B VNH111 10A VNH211 15A Model Operating fluid pressure Fluid Operation 0 to 7.0MPa 0 to

Hs A B A B Proper Auto Switch Mounting Position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W Bore size (mm) B B A A B A B A 32 3 11 51 43 6 46 5.5 45.5 40 5.5 13.5 49.5 57.5 8.5 52.5 8 52 50 19 11 53.5 61.5 14 56.5 13.5 56 63 22 14 59 67 17 62 16.5 61.5 Auto Switch Mounting Height (mm) D-A7H, A80H D-F7, J79, F7W D-J79W

Cv C[dm2/(sbar)] b Cv Flow characteristics 1 2 (P A) 2 3 (A R) Body ported Max. operating frequency (c/s) (AC/DC) (1) 15 21/21 or less 0.125 15 21/21 or less 0.250 Response time (ms) (AC/DC) (2) Weight (kg) (3) Note 1) Minimum operating frequency: As per JIS B 8373 (Once in 30 days) Note 2) Based on JIS B 8375-1981 (Supply pressure; 0.5 MPa; without surge voltage suppressor) Note 3) Value

Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.

Pressure gauge port M Q N F J K P E Bracket (option) AR50, 60 Port size Square embedded type pressure gauge (option) A D C L OUT IN G Pressure gauge (option) B Pressure gauge port M N Bracket (option) Q K P F E J Standard specification Accessory specification With pressure gauge Bracket mounting size Panel mount Model Port sizes A 25 40 53 53 70 75 90 95 J 25 30 30 41 50 50 70 70 B 58 94

8 Product image For PROFIBUS DP (Plug, B-coded) Socket Plug Plug Socket Number of functional poles M12: 2 pins M12: 3 pins M12: 4 pins Key type B-coded (Reverse key) 3 4 4 3 5 1: VP 4: B Line 5 1: 2: A Line (Green) 3: 4: B Line (Red) 5: 390 1 2 2 1 Pin assignment 220 2: A Line 3: DGND Plug, B-coded Plug, B-coded (Viewed from the plug/socket side) 390 Fixed cable length 5 m Cable O.D

With external pilot specifications (Pitch) 20.5 15.8 9.5 17.5 P = 16 11.9 9.2 25.2 11.8 5.4 30.6 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 49.9 E 3/5 E 3/5 E 3/5 E 3/5 63.5 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B P 1 1 P P 1 1 P PE One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 10 3/8" PE X X One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, 5/32" 6, 1/4" 8, 5/16

Connector location on U side (FU) 3.5 163 10.7 47 106 71.7 9 9 U side 27 Manual override n X 12 12 2 B 4 A 8 2 B 4 A A A B A B A B A B A B A 7 SMC SMC SMC SMC SMC SMC SMC A A A A A A A B B B 2 B 4 A Indicator light 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 P = 25 2 B 4 A 1 50.5 44 X Stations 38 27 Connector location on D side (FD) 11.7 16.2 139.9 (Single) 43.2 49.7 D side 148.9

1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield

30 d d C D D C H B Material: Carbon steel Material: Carbon steel B H Part no. d H B C D Applicable bore size (mm) Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6

Hs A B A B Proper auto switch mounting position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W D-F7LF Bore size (mm) B B A A B A B A B A 32 11 10 50 51 3 43 6 46 5.5 45.5 40 13.5 12.5 56.5 57.5 5.5 49.5 8.5 52.5 8 52 50 18 19 61.5 60.5 11 53.5 14 56.5 13.5 56 63 22 21 67 66 14 59 17 62 16.5 61.5 Auto switch mounting height

Without brake C section details Cross section BB l\rodel D F L 1 5 4 231 LXPB B-50 L X P B B . 7 5 173 256 52 L X P B _ B _ 1 0 0 204 281 246 323 LXPB B -.125 L X P B B 1 5 0 271 348 120 90 L X P B _ B _ 1 7 5 296 373 LXPB_B_-200 321 394 ?$rc zs S8[i8$ [10 Camraclnectl' 0i|llomiom $lift $crExi tlE LXPB S With brake I I shows the localion at which origin point swiich operates.