CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages, please consult with SMC.
View port G1/2 5 10 30 50 100 300 Flow rate (L/min) Conditions Fluid: Turbine oil Class 2 VG56 Measured pressure: 14 MPa Viscosity: 45 mm2/s Filter material: Paper Nominal filtration: 10 m FH64 Series Refer to page 529 for Microswitch for differential pressure indication switch. 16 0.1 10/12 0.05 0.04 0.03 06/08 Pressure drop (MPa) 0.02 03/04 0.01 0.005 0.003 5 10 30 50 100 300 Flow rate
Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE14 48 39 4.6
Without bracket (Bottom view) Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13(Z) 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14(Z) 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26(Z) 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38(Z) 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13(Z) 48 39 4.6 12 11.5 52 28
Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN LVC Wide selection of port size and variations LVA LVH Threaded type (6A to 50A) Flange type (32F to 80F) LVD LVQ LQ LVN Low water hammer TI/ TIL PA Max.1.2 MPa PAX PB In the case of VNC211A (N.C. 0.5 MPa) Peak pressure when valve is closed (MPa) Large valve capacity Av factor 3.0 x 10-5 to 160 x 10-5 (VNC1 to VNC7) Cv factor 49 to 100
Rc1/4 Rc3/8 Bottom Note) When equipped with control unit, 1 or 2 stations are used for mounting. 6 Series VQ7-6 DIN Connector Type VV71-100 80 2n-Rc1/4, 3/8 100 80 9 37 9 23 14 U side 15 R4.5 Manual override Indicator light R4.5 53.5 P=43 9 9 53.5 P=43 20 9 23 38 B B B B B B B B B SMC SMC SMC A PA PA PA PA A A A A B A L1 L2 L2 L1 B A B SMC A B A 4n-Rc1/4, 3/8 (ports A, B) PA L side R side
Absolute accuracy (77F) Current consumption 100 mA or less Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.6 lbs (300 g) Note 1) M12 (4-pin) connector can be connected. Note 2) When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.
Selects the time to hold the input signal. 15 ms 2: 100 ms 3: 200 ms 1: True (Auto) Error is automatically cleared when the short circuit is fixed.
283 59 112 Flow rate quoted at: 0.5MPa supply 0.03MPa pressure drop NAL900 100 288 63 2 H O W T O O R D E R L U B R I C AT O R S E R I E S AL AL800-12 (1 14 PT) AL800-14 (1 12 PT) AL900-20 (2 PT) Courtesy of Steven Engineering, Inc. !
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
VCHC ASR ASQ ASD230F ASD330F ASD430F 100 200 400 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 07,08,09,10,11 300 06 200 50 100 100 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 12 10,11 10,11,12 08,09 1000 500 06,07 500 0 5 10 0 5 10
[GSDML ] PLC [SC_MonSs] [Monitior Short Enable 1 Circuit(Power) ] Disable 1 Enable [OC_Mon] [Monitor Open 2 2 Disable Circuit] [Inrush] [Inruch Current Enable 100 mse 3 Disable Filter] 0.1 ms [Filter_T] [Input Filtering 1.0 ms 4 1.0 ms 10 ms Time] 20 ms 1.0 ms [SigExt_T] [Input Extention 15 ms 15 ms 5 100 ms Time] 200 ms Enable Val: 1 65000 4 ON/OFF [Counter] []
O.D.218 X I.D.175 X T3 1 pc. Gasket AL-62S AL63S 3 pcs. AL-31S y JIS B2401G35 5 pcs. O ring JIS B2401G35 1 pc. JIS B2401G35 3 pcs. JIS B2401G35 3 pcs.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
Pressure Sensor for General Fluids RoHS PSE57 Series How to Order PSE57 0 01 Option (Lead wire) Sensor range 0 Positive pressure [0 to 1 MPa] 3 Compound pressure [100 to 100 kPa] 4 Positive pressure [0 to 500 kPa] 5 Positive pressure [0 to 2 MPa] 6 Positive pressure [0 to 5 MPa] 7 Positive pressure [0 to 10 MPa] Nil Lead wire and M12 connector (3 m), Straight L Lead wire and M12 connector
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
16 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 15, 30, 45, 60, 75, 100 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.
EDS Enable (SC_MonSs) 1 Disable Enable (Inrush) 100 msec 2 Disable 0.1 ms 1.0 ms 1.0 ms 10 ms 20 ms 3 (Filter_T) 1.0 ms 15 ms 15 ms 100 ms 200 ms 4 (SigExt_T) Enable (SC_MonOp) 5 1 Disable Auto (SC_RstOp) 6 Manual Enable 7 (OC_Mon) 6 Disable Clear OFF 2 6 Hold 8 (Fault_MD) ForceON ON Clear OFF 2 3 6 Hold 9 (Idle_MD) ForceON ON ON Enable Val165000
How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body Hexagon lock nut Round lock nut J Nil Lock nut option Body size Indication symbol Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Made to Order Refer to page 622 for details. Applicable tubing O.D.