SMC Corporation of America
Elite Part Number Search
Search Results "RZQA63TN-200-110"

Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry-air at low temperature. Note 2) Use turbine oil Class1 (ISO VG32), if lubricated.

15 2.0 HAA22-14 HAW22-14 AT22C-14 AFF11B-06 IDF15CAM450-06 AMD450-06 22 3.0 HAA37-14 HAW37-14 AT22C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 27 3.5 HAA37-14 HAW37-14 AT37C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 37 5.0 HAW55-20 AT37C-14 AFF37B-14 IDF37C1-3 AM650-14 AMD650-14 55 7.5 HAW75-20 AT55C-20 IDF55C-3 AM850-20 AM850-20 AMD850-20 75 10.0 HAW110-30 AT75C-20 IDF75C-3 AMD850-20 110

110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMD150 1 8 1 4 3 8 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 166 187 187 218 218 241 241 277 334 24 27 27 32 32

Q 50 R 88 S 3.2 AM 1 2 3 4 , 9 36 205 19 100 106 3 106 10 AMF450 212 22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 1 Misc. , , , 1 1 4.5 4.5 6 3 4 257 314 406 30 40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 44 66 96 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 14-20-47 7 Series

110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMH150 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106

110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A93 M9N M9P M9B F9NW F9PW F9BW F9BA 200 V Grommet MVGQ Yes Yes 100 V 12 V Relay, PLC 2-wire 24 V Connector CC 12 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) RB 5 V, 12 V IC circuit 3-wire (PNP) Grommet J 2-wire

110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24

Q 50 R 88 S 3.2 Related poroducts 36 9 205 19 100 106 3 106 10 1 2 3 4 , AMF450 1 212 22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 , , , 1 1 3 4 44 66 96 257 314 406 30 40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 AMF450SAME

110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24 27 27

to 120VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Other 1 2 3 4 5 6 9 Option D: Type D DIN terminal Nil G None With pressure gauge How to Order Pilot Valve Assemblies Y: Type Y DIN terminal SF4 1 G 80 Rated coil voltage 100VAC (50/60Hz) 200VAC (50/60Hz) 110 to 120VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Other 1 2 3 4 5 6 9 For soft start-up valve Note) The grommet type can have a surge

Model L K J M N T W H E LQ2P2A 1/4" 3/16" 1/8" 3/8" 1/4" 1/2" 3/8" 3/4" 1/2" 14.5 LQ2P2B LQ2P2C 18 6 19 19.9 7 16 73 LQ2P5B LQ2P5A LQ2P4B LQ2P4A LQ2P3B LQ2P3A 83 20.5 24 6 22 26.2 7 24 95 82 24.5 30 9 28 33.1 21 7 30 110 93 30.5 36 9 32 40 26 10 36 108 Union: LQ2U Metric sizes Applicable tubing O.D.

) Double Closed 1.9 0.48 0.46 0.57 2.1 0.36 center Base mounted (With sub-plate) 1/8 Note 1) M5 x 0.8 SYJA740-01 0.36 0.86 3.4 Exhaust 1.2 200 (120) 3 position 0.35 0.48 [0.57] [0.41] [1.3] center 3.3 0.78 0.43 Pressure 0.45 0.56 2.1 [0.85] [0.25] [0.54] center 170 (90) Single 2.3 0.61 0.35 0.74 2.9 0.41 2 position 190 (110) Double Closed 1.9 0.50 0.44 0.60 2.2 0.46 center 1/4 Note 1) M5

to 120VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Other 1 2 3 4 5 6 9 Option D: Type D DIN terminal Nil G None With pressure gauge How to Order Pilot Valve Assemblies Y: Type Y DIN terminal SF4 1 G 80 Rated coil voltage 100VAC (50/60Hz) 200VAC (50/60Hz) 110 to 120VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Other 1 2 3 4 5 6 9 For soft start-up valve Note) The grommet type can have a surge

/km Capacity 30pF/m or less Impedance 135 165 Cable length [m] 1200 1000 400 200 100 Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Lower-level bus Core cross-section 0.34mm2 or more Wire diameter 0.64mm or more 10 11 The wirings are described in the following order.

Station n L1 L2 L3 L4 Station 20 341 328 304 296 3 69 56 32 24 6 117 104 80 72 8 149 136 112 104 10 181 168 144 136 Station 2 53 40 16 8 4 85 72 48 40 5 101 88 64 56 7 133 120 96 88 9 165 152 128 120 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 4-4-27 Series SYJ500

50 0 to 100 X X X X Conductive NBR 50 10 to 200 X X X X X Conductive silicon rubber The above table covers only general characteristics of subject rubber materials.

(Where the load voltage is 110 VAC) When the load voltage is increased by more than 10% to the rating of applicable auto switches (except D-A73C/A80C/C73C/C80C/90/97/A79W) above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the range of the load current range, 110 VAC.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.

VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID Series Working Principle Flow Rate Inlet pressure: 0.7 MPa Pressure drop (MPa) HAA HAW The compressed air that flowed in from the IN side passes through the 4 port solenoid valve, and after it is dehumidified at adsorption cylinder