SMC Corporation of America
Elite Part Number Search
Search Results "RZQA63TN-200-90"

Symbol Rotation angle Insulated adapter Pilot port Nil IN OUT 90 Pilot port No XCA 90 Pilot port XCA 270 XCC IN OUT 270 Pilot port 1 (IN) 2 (OUT) XCC OUT IN Pilot port With insulated adapter XA XA Insulated adapter IN OUT 90 XAA 90 270 XAC Yes XAA 1 (IN) 2 (OUT) Pilot port With insulated adapter OUT IN 270 Pilot port With insulated adapter XAC IN OUT * For details about the insulated adapter

Additional weight 0.23/50 stroke Stroke 100 stroke 0.46 + 100 / 50 X 0.23 = 0.92kg Standard Stroke (mm) Size Standard stroke Max. stroke(mm) 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Contact SMC for any intermediate strokes that are not indicated above, as they will be produced upon receipt of order.

AMG Finalize the model number. 5 AFF Refer to pages 90, 94. AM Select accessories sold separately. 6 Refer to page 99.

Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.

Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.

250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure

400 500 100 200 300 400 600 500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.

psig (1.4 MPa) 50 0.34 0.69 100 0.62 90 80 40 0.28 0.55 Delivery pressure (slpm) Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig) 0.48 70 0.41 60 30 0.21 0.34 50 0.28 20 0.14 40 0.21 30 0.14 20 10 0.07 0.00 0.07 0 10 0 0.00 0 20 40 60 80 Flow rate (slpm, N2) 0 100 200 300 400 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.

Note 2) Except double (latching). 5 6 Low wattage type Y (2) Note) 200/220 VAC models are applicable to the F and L kits.

Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (8): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range. TEMP READY alarm (AL12) is simultaneously activated.

94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Type Nozzle model Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 Nozzle size Standard type Nil 01 02 03 04 11 12 13 21 22 23 24 31 32 33 34

Nonstandard Compatible Motors: Motor model Corresponding driver model Power supply voltage (AC) Motor output (W) MSM011P1A Matsushita Electric Industrial Co., LTD 100/115 MSD011P1E MSM012P1A 100 200/230 MSD013P1E 100/115 MR-C10A1 Mitsubishi Electric Corporation HC-PQ13 100 200/230 MR-C10A Yaskawa Electric Corporation 100/115 SGDE-01BP 100 SGME-01BF12 200/230 SGDE-01AP SGME-01AF12 Refer to

0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of switch ON [mm]

Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U VNB2-10A VNB2-15A VNB3-20A VNB4-25A 3 8 1 2 3 4 1 144.5 55 125.5 52 26 4.5 24.3 2.3 25 34 63 42 28 14 72.5 80.5 75 80 84.5 124 60.5 73 135.5 151.5 137 153 156 172 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 80 90 50 60 35 44 17.5 22 84 100 92 108 84 90 89 95 93.5 99.5 Port size: 10A, 15A, 20A, 25A Vacuum pilot K L N

AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 No. Part no.

Fig. 8-8 Cooling Capacity (HRL100/200/300-A-20) Documents HRL Series 8-8 HRX-OM-Y098 Chapter 8 Documents 8.5 Pump Capacity 8.5.1 HRL100-A-20 CH1 0.6 60 0.5 50 Circulating fluid outlet Pressure [MPa] 0.4 40 Lifting head [m] Usable flow rate range 0.3 30 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow[L/min] Fig. 8-9 Pump capacity(HRL100

58 110 170 200 50 152 MHL2-16D2Z 90 95 110 78 130 210 240 70 192 J dimension is at fully closed.

300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s MY2C MY2 H/HT Maximum Load Mass Select the load mass from within the range of limits shown in the graphs.

O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMH150 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122