M2 3.0 5.2 9.0 15 24 38 60 3.0 5.0 8.5 14 23 35 50 M3 1.0 1.7 2.4 5.0 8.0 15 19 2.0 3.0 5.0 10 20 35 50 m2 7 10.4 15 23 33 48 72 7 10 14 21 30 42 60 m3 2.1 3 4.5 6.6 10 14 21 2.1 3 4.2 6 8.2 11.5 16 16 20 25 32 40 50 63 16 20 25 32 40 50 63 MY1MW MX MTS MY MY1CW CY MG The above values are the maximum allowable values for moment and load.
Note 1) C 5 to 35 Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) C 1.0 Circulating fluid system Rated flow 50/60 Hz (Outlet) Note 6) L/min 42/56 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50/60 Hz Note 7) L/min 28/42 Tank capacity L 18 Circulating fluid
a lead wire cover on the auto switches for size 50 and 63 cylinders.
MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 2 Series MXQ Theoretical Output IN OUT Application of the dual rod system generates double the output of conventional cylinders.
K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
50 H 24 35 35 40 40 E 41.5 55 55 72.5 77.5 AC20C AC25C AC30C AC40C 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 2 Note 1) 50 71 71 88 88 45 50 50 75 75 126 167 167 220 235 114 143 146 183 185 26.5 28 31 36 36 0 3.5 3.5 3 AC40C-06 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) 5 50 3.5 35 6 50 8 55 6.5 45 8 50 10.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage. Changing coils from AC to DC and vice versa is impossible, because of different core shapes.
page 12 for dimensions. 200, 220, 230, 240 VAC (50 Hz), 200 to 260V (60 Hz) 2 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 380, 400, 415 VAC (50 Hz), 380 to 420V (60 Hz) 3 Compound 420, 440, 480 VAC (50 Hz), 420 to 520V (60 Hz) 4 Please refer to page 11 for dimensions.
75, 100, 125, 150, 200 M5 X 0. 8Depth10 5.6 25 90 62 45 15.5 9.5Depth6 24 106 22 M6 X 1Depth10 13 11 84 M6 X 1Depth12 6.8 30 103 65 45 16.5 26.5 11Depth8 M8 X 1.25Depth14 120 27 13 15 89 75, 100 125, 150 200, 250 300 M6 X 1Depth12 6.8 35 118 70 50 16.5 26.5 11Depth8 M8 X 1.25Depth14 135 32 13 15 94 8.6 40 140 75 50 34.5 M10 X 1.5Depth18 22 M8 X 1.25Depth16 14Depth10 160 37 16 18 107 45 170
Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
Substitute 50 for m and 0.3 for . 4. Calculation of kinetic energy E1 Using the equation suitable for the classification of impact.
Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)
Note 1) Perpendicular electrical entry is not available for 50 and 63.
67h9 32H9 12 22H9 10 4.5 3 6.5 17 8.6 14 8.5 85.4 80 10 38 22 19 6 15.5 63 37.5 100 50 10 37.5 75h9 77h9 35H9 13 26H9 12 5 3 7.5 20 10.5 18 10.5 (mm) JC JD JJ JU P Q S SD SE SF SU UU WA WB WC WD WE WF XA XB XC YA YB YC Size 10 20 30 50 M 8 x 1.25 12 M5 x 0.8 M 8 x 1 M5 x 0.8 34 92 9 13 45 17.7 47 15 3H9 3.5 M5 x 0.8 8 32 27 3H9 3.5 19 3H9 3.5 M10 x 1.5 15 M6 x 1 M10 x 1 M5 x 0.8 37 117 10
F (C) Correction factor 1.41 41 to 86 (5 to 30) Air ow capacity scfm (m3/min) (ANR) 50 Hz 565 (16) 709.8 (20.1) 882.8 (25) 50 (10) 1 1.21 95 (35) 60 Hz 663.8 (18.8) 836.9 (23.7) 953.4 (27) 59 (15) 1.4 1 104 (40) 61 (16) or more 1.5 0.92 113 (45) The maximum coefficient value is 1.5 due to the drainage separation performance. 0.75 122 (50) 0.63 131 (55) Data D: Inlet Air Pressure 0.53 140
(n-1) x 19 45 88 19 2 2 Manual override 152 (Double dual 3-port) 133 118 (Single) 165 (3-position) LERR.