16 20 25 32, 40 50, 63 80 100 125, 140 160 12 16 20 25 40 63 80 100 140 160 3-050 4-070 5-080 6-100 8-125 10-150 16-200 20-250 22-250 24-300 Precautions 2.
25, 30 40 50, 63 80 100 125, 140 160 6 10 15 20 30 40 63 80 100 140 160 Maintenance Standard Warning 1.
150 -X 20 20 equivalent 25 to 300 32 25 to 400 2040 25 to 600 50 25 to 600 Data 63 25 to 600 Stroke reading cylinder Series CE1 Series CEP1 CEU1 CEU5 RS-232C RS-232C+BCD Extension Cable Count data output Output transistor mode Power supply voltage NPN PNP NPN PNP NPN PNP Cable length (m) Output transistor mode Power supply voltage 5 10 15 20 100 VAC 24 VDC 100 to 240 VAC Note) Detection
150 -X 20 20 equivalent 25 to 300 32 25 to 400 2040 25 to 600 50 25 to 600 Data 63 25 to 600 Stroke reading cylinder Series CE1 Series CEP1 CEU1 CEU5 RS-232C RS-232C+BCD Extension Cable Count data output Output transistor mode Power supply voltage NPN PNP NPN PNP NPN PNP Cable length (m) Output transistor mode Power supply voltage 5 10 15 20 100 VAC 24 VDC 100 to 240 VAC Note) Detection
Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models. JIS standard compact hydraulic cylinder; Nominal pressure: 10MPa; Bore sizes: 20~25; Mounting: basic type; Auto switch capable
Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models. JIS standard compact hydraulic cylinder; Nominal pressure: 16MPa; Bore sizes: 20~25; Mounting: basic type; Auto switch capable
Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models. JIS standard compact hydraulic cylinder; Nominal pressure: 10MPa; Bore sizes: 20~25; Mounting: basic type; Auto switch capable
Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models. JIS standard compact hydraulic cylinder; Nominal pressure: 16MPa; Bore sizes: 20~25; Mounting: basic type; Auto switch capable
Unique air cushion construction with no cushion ring, Wide size variations from °20 to °100, Nearly three times the allowable kinetic energy, Improved noise reduction * and repeatability, Interchangeable mounting, "Cylinder, 3-POSITION CYLINDER
The MGQ offers bore sizes from 12 to 100mm and is switch capable.Compact guide cylinder, Ball bushing bearing, Bore sizes: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 *, Strokes from 10mm through 200mm depending upon bore size, Variety of switches and a variety of lead wire lengths, BASE CYLINDER, ACTUATOR, MGQ GUIDED CYLINDER, L6, 32MM MGQ COPPER-FREE, 3.17794 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, MGQ GUIDED CYLINDER, L6, 32MM MGQ COPPER-FREE, 3.4784 lb
750 20 90 32 330 216.3 230 490 1160 1485 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 1000 20 105 41 330 216.3 230 490 1415 1750 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 500 20 115 37 400 267.4 230 510 915 1250 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 750 20 130 50 400 267.4 230 510 1175 1510 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B)
CDRBU2W20-S 0 0.043 0.004 0.012 42 34.5 30 20 1.5 17 10 0.5 11.5 11 M5 x 0.8 4.5 M4 x 0.7 26 4 36 44 59 25 6 14 CDRBU2W30-S 0.005 0.014 0 0.043 50 47.5 31 22 2 17.5 12 1 12 13 M5 x 0.8 5.5 M5 x 0.8 29 4.5 42 52 69 25 8 16 93 Series CDRBU2 Dimensions: 10, 15, 20, 30 (With auto switch unit) Double vane type Following figures show actuators for 90 and 180 when B port is pressurized.
Insulation color Dot mark Dot color 12 Light brown Red 13 Yellow Black 14 Yellow Red 15 Light green Black 16 Light green Red 17 Gray Black 18 Gray Red 19 White Black 20 White Red Pulse input usable only with differential. Only 1.5 m cables usable with open collector. (12) L 20 19 Round terminal 0.5-5 Green (22) (25) (40) (10) Weight 2 1 (45) Product no.
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 5, 10, 15, 20, 25, 30 20, 25, 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 50, 63, 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50 Intermediate strokes are available as a special order.
MHR2-10/MDHR2-10 MHR2-20/MDHR2-20 50 60 Overhang distance H (mm) Overhang distance H (mm) 50 40 Pressure 0.2 MPa Pressure 0.2 MPa 40 30 30 0.3 MPa External grip 0.3 MPa 0.4 MPa 20 0.4 MPa 20 0.5 MPa 0.5 MPa 0.6 MPa 10 0.6 MPa 10 0 10 20 30 40 50 0 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-
12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room
Air consumption Q [Nl/min.] 15 20 30 40 50 15 20 30 40 50 1 1 32 2 0.4 0.5 0.5 20 25 0.4 0.3 160 2 10 10 125 12 0.3 16 1.5 2 3 4 5 1.5 2 3 4 5 9 0.2 0.2 100 8 80 63 50 10 7.5 0.1 10 6 1 1 6 5 40 0.05 4 5 0.6 0.5 0.4 0.3 0.2 0.15 0.1 0.04 32 4 1500 2000 3000 4000 5000 0.03 3 25 20 0.02 2 2.5 16 1.5 1 1000 0.01 1 0.05 0.04 0.03 10 1 150 200 300 400 500 0.5 0.4 0.3 0.005 0.02 0.015 0.01 6 0.2
10 145 12 15 160 28 55 9 75 52 28 36 11 4.5 163 161 36 12 10 72 90 55 50 45 25 12 155 12 15 170 32 68 9 80 60 32 45 12 5.5 175 170 45 12 10 90 110 70 40 50 12 5.5 190 185 50 63 50 25 12 170 16 20 190 40 80 9 90 70 16 10 100 120 80 50 63 14 6.5 215 210 63 80 63 30 16 190 16 20 210 50 100 12 110 90 16 12 126 153 100 60 100 120 75 35 16 205 14 20 140 25 230 110 60 20 75 16 6.5 230 220 71 14.5