77.5 L2 43 57 57 75 80 L1 41.5 55 55 72.5 77.5 L2 43 57 57 75 80 L3 43 57 57 75 80 L1 41.5 55 55 72.5 77.5 L2 43 57 57 75 80 L1 41.5 55 55 72.5 77.5 L2 43 57 57 75 80 L3 61 76 76 99 104 AC20C AC25C AC30C AC40C AC40C-06 Attachment Model L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80 60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-20D MHF2-16D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 Courtesy of Steven Engineering,
Double acting, Single rod 25, 50, 75, 100, 125, 150 1/8 25, 50, 75, 100, 125, 150, 200 1/4 25, 50, 75, 100, 125, 150, 200, 250, 300 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item 20/25/32/40 2 Bore size Suction flow rate L/min (ANR) 20/25/32/40 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing
Caution Theoretical Cylinder Thrust 6, 10 15, 20, 25, 32, 40 50, 63 CY3B CY3R CY3B CY3R CY1S 63 63 1200 40 40 1100 3000 100 90 80 70 60 50 40 30 20 10 Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) H CY1L Bore size 10 Bore size 2500 1000 900 800 700 10 50 50 H 32 32 2000 CY1H 1500 600 25 25 500 400 300 200 100 CY1F 1000
/32 10-32UNF 6, 10, 16, 20 Universal type AS221F-N01 AS231F-N01 NPT1/8 20, 25, 32 AS221F-N02 AS231F-N02 NPT1/4 20, 25, 32, 40 AS321F-N02 AS331F-N02 NPT1/4 40, 50, 63 AS321F-N03 AS331F-N03 NPT3/8 40, 50, 63 AS421F-N04 AS431F-N04 NPT1/2 63, 80, 100 Note 1) Elbow type only.
psig (0.69 MPa) inlet Inlet pressure: 50 psig (0.34 MPa) inlet 0.97 (24.6) 70 0.48 60 0.41 1.18 (30.0) Delivery pressure (MPa) Delivery pressure (psig) 50 0.34 Max. 3.95 (100.3) 40 0.28 30 0.21 0.44 (11.2) 1.42 (36.1) 20 0.14 10 0.07 0 0.00 1.25 (31.8) A 0 20 40 60 80 100 120 140 Flow rate (slpm, N2) SL5210 100 psig (0.69 MPa) 30 psig (0.21 MPa) Inlet pressure: 60 psig (0.41 MPa) 2 x 10-
IDF240D-3-W Parts marked with square brackets are included in the package (900) 1647 (80) 770 1550 10K 100 Flange 10K 100 Compressed air inlet (730) 10K 100 Flange 10K 100 1640 Terminal block Compressed air outlet Power supply port signal connection port (36) R1 Cooling water outlet R1 Cooling water inlet R1 (273) (223) (703) C1/2 R Grommet with membrane (Lower hole 36) (467) Rc 1/2 R1
A B 63 63 80 85 90 100 C Port size Rc(PT) INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model No. 1/4 15 15 15 20 22 22 141 164.5 170 180 230 251 3/8 1/4 , 3/8 , 1/2 3/4 B C D E F Port size Rc(PT) 3/4 , 1 1 Model No. A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24
kPa 100 kPa 100kPa to 100 kPa 1 MPa 0 0 to 1 MPa For positive pressure 500 kPa 0 0 to 500 kPa C D Range Rated differential pressure range 1 4 For low differential pressure 0 to 2 kPa 2 kPa 0 A C B D Pressure Differential pressure Pressure Differential pressure A C B D 16-3-37 6 Series PSE300 Internal Circuit PSE300 NPN open collector output (2 outputs), Max. 30 V or 80 mA, residual voltage
, 200, 300 (N) 100, 200, 300, 400, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
80 300 300 1.0 RS1H80 RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 0.7 10 20 30 40 10 20 30 40 0 0 0.6 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 Graphe Graphr Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 0.2 0.1 80 80 0 5000 1000 2000 3000 4000 Lateral load F [N] 32 70 70 60 60 50 50 32 40 40 30 30 20 20 20 20 10 10 0 0 10 20 30 40 10 20
/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150 (1.5" Bore) NBT-200 (2" & 2.5" Bore) NBT-325 (3.25" & 4" Bore) "SC" auto switch CDQ2/NCDQ Direct Body Mount BQ-2 (32/40/50/63/80/100 Bore) Screw & Nut Kit included with cylinder "SC" auto switch CDRA1 Rail Mounting P294020-24 Screw & Nut Kit for 2 Auto Switches (50/63/80/100 Bore) -F7PSAPC -F7PSC CD85-A Rail Mounting BQ-1 (8/10/12/16/20/25
H5 Initial power / Power consumption (W) 100 VAC 200/40 400/70 400/80 600/130 800/180 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
Grease pack part no.: GR-S-010 (10 g) 80 Compact Cylinder/Water Resistant: Double Acting, Single Rod Series CQ2 Replacement Procedure is 20, 25, 32, 40 50, 63, 80, 100 P.290 Construction Standard (40 to 100) !2 !3 !1 !0 !3 !3 !2 !1 Without Auto Switch With Auto Switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).
point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm)
When exceeding the air cushion stroke ranges shown on page 28, the piston speed should be 100 to 200mm/s. 1500 Max. operating frequency (cycle/min) 70 45 25 80 Extended 4.22 6.86 8.34 1.96 Spring force (N) Note 2) The piston speed is 100 to 1000mm/s for centralized piping.
-so (rr s) E ; -40 {11 6) a 3 0 ( 8 7 ) E 3 -2o (5.8) ' -1O(2.91 0 10 20 30 40 50 60 70 80 90 100 1r0 120 lo 7t (1 4j (2 1) (2 A) (3 5) (4 2) Suclton flow rale It/min(scfm)] ) NIr $eries I Option Specifications Gauge Adapter for external mount gauge External gauge model Not 1) Adapier lits jn plac ol srandard iniegral g6ugs. Note 2) Order en6hal gauge rcd6lno sepalai6ly.