S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).
S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).
S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).
(A) 4 (B) 2 Flow-rate Characteristics 1 (P) 5 (R1) 3 (R2) 4, 2 5, 3 (A, B EA, EB) 1 4, 2 (P A, B) Flow-rate characteristics Series Response time (msec) Mass (g) 4-position dual 3-port valve Note) (A) Type of actuation Seal C [dm3/(sbar)] C [dm3/(sbar)] Cv b Cv b (A) 4 (B) 2 140 140 170 170 185 185 185 185 185 185 170 225 215 260 250 285 275 285 275 285 275 250 0.30 0.50 0.30 0.50 0.30
B 220V Dryer Capacity Model A Part No.
Bracket Nil B None With bracket Refer to the table (4) if a bracket is ordered separately.
Terminal B External temperature sensor 15 9 5 Resistance Bulb Terminal B connector D-sub 15 pin (Socket type) Fixed screw: M2.6 15 FG 10.2 Power Supply Cable Table 10-2 Power Supply Cable Specifications Description HEC006 HEC012 Connector Rating Voltage: 250V Rating Voltage: 250V Rating Current: 10A Rating Current: 23A Cable Rating Voltage: 300V Rating Voltage: 300V AWG14 AWG14 Color: Black
[mm] Model 1 D1 Weight [g] X (X) Y X (X) Y Nylon Urethane a b 4 6 KQ2T04-06A1 10.4 7.7 10 8.2 9.7 12 15.3 16.3 19.4 13.3 13.3 5.7 6.8 6 3.2 7.1 6.6 3 3.3 Q2 Q2 Oval type Round type Applicable tubing b 8 to 16 4, 6 6 8 KQ2T06-08A1 13.2 9.7 12 10.4 13 17.2 17.3 22.4 14.2 13.3 7.3 8.4 8 4.2 16.4 16.4 4.5 5.3 2 x N L3 L1 M1 Q1 Q1 8 10 KQ2T08-10A 15.9 15.6 13.2 13 19.6 19.2 26.2 15.6 14.2 8.4
FKM/EPDM O-ring e O-ring e 10A to 25A 15A to 25A Diaphragm assembly Diaphragm assembly Stainless steel, Brass, NBR Stainless steel, Brass, NBR r r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A to
steel, Brass FKM/EPDM O-ring e O-ring e 10A to 25A 15A to 25A Stainless steel, Brass, NBR Stainless steel, Brass, NBR Disk assembly Disk assembly r r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A
-5 (For VQZ100) VVQZ200-10A-5 (For VQZ200) VVQZ300-10A-5 (For VQZ300) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.
1 Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less
-5 VVQZ200-10A-5 VVQZ300-10A-5 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.
-2 VVQZ200-10A-2 VVQZ300-10A-2 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.
Stainless Steel (mm) A B C D E F G H J L Bracket part no.
A B A B A B A A A B For the I/O Unit part number mounted, refer to the following pages.
SMC SMC SMC 23 20 B A VZ 9 PA A B VF B A VFR PA A B VP4 L1 L2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B A A PA VZS A B SMC VFS PA A VS4 B VQ7 PA A L side R side (2n-1/8) EVS 38 D side VFN 3 68.5 (A, B port) 4n-1/4, 3/8 16 120.5 (Single) 44 155 (3 position)
Orifice and Port Size Combinations Class Orifice size (mm) Port size 3 2 4 5 7 10 T Conduit terminal 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) Available types of electrical entry are either G, C and T.
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
2 18.5 12 12 e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 10 Lead wire length: L0, 0.6 m L1, 1.5 m L2, 3.0 m For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 48.8 30 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Formula