(Adjustable) 1 to 10% of set prss. (Variable) 3% F .S. or less (Fixed) 1 to 10% of set prss.
Orifice size (mm) 2 3 4 5 7 10 Symbol 2 3 4 5 7 10 Class 3 Class 2 Class 4 Electrical entry G Grommet C Conduit Refer to the table below for orifice and port size combinations.
(P.16) 9 - 4ON DC24V LED POWER ALARM LEDPWR LEDALM CN4 I/O 12.P.48 5() , () 6 10 - 3. 3.1.
(Specifications: -101 to 101 kPa) Do not exceed the specified maximum allowable load. Otherwise it can cause damage or shorten the lifetime of the Pressure switch. Input data to the Pressure switch is not erased after the power is off. (Writing time: 100,000 times) Reserve a space for maintenance.
V114-5LU Electrical entry L shaped plug connector (L) Coil rated voltage [V] 24 Allowable voltage fluctuation -10 to 10% Power consumption [W] 0.4 [Starting 0.4,Holding 0.1] Surge voltage suppressor Please refer to page 1367 of the Best Pneumatics catalogue. Indicator LED LED 14 - 4-3.
ZS-10-5 A-50 1 pc. 0.6 m 30 3 m 50 5 m Specifications Model ZSP1-B ZSP1-S Fluid Air Operating pressure range 20 to 101 kPa Applicable adsorption nozzle dia. 0.3 to 0.7 (Refer to Graph (1) on page 16-7-3.) 0.5 to 1.2 (Refer to Graph (2) on page 16-7-3.)
ZS-10-5 A-50 1 pc. 0.6 m 30 3 m 50 5 m Specifications Model ZSP1-B ZSP1-S Fluid Air Operating pressure range 20 to 101 kPa Applicable adsorption nozzle dia. 0.3 to 0.7 (Refer to Graph (1) on page 16-7-3.) 0.5 to 1.2 (Refer to Graph (2) on page 16-7-3.)
Manifold Type: Base Mounted, Bar Manifold, Compact, Individual Wiring, Valve Stations: 10 Stations, A, B Port: ø6 One-touch Fitting NPT, Q: -
Manifold Type: Base Mounted, Valve Stations: 10 Stations, A, B Port: ø6 One-touch Fitting NPT, CE Marked: -
G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell
G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell
PSE540(A) PSE541(A) PSE543(A) Rated pressure range 0 to 1 MPa 0 to -101 kPa -100 to 100 kPa Extension analog output range -0.1 to 0 MPa 10.1 to 0 kPa Withstand pressure 1.5 MPa 500 kPa Applicable Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC10%, ripple (p-p) 10% or less (Protected against inverse connection) Current consumption 15 mA or less Analog output: 1 to
collector 2 outputs, with suction filter Fixed SI unit Note 7) 0 to 101 kPa/NPN open collector 1 output + analog voltage, with suction filter With unit switching function Note 6) (Initial value psi) 0 to 101 kPa/PNP open collector 1 output + analog voltage, with suction filter P 100 to 100 kPa/NPN open collector 2 outputs, with suction filter Note 6) Under the New Measurement Law, sales
4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell for the domestic
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
Note) For wear ring A of 10, please consult with SMC. Seal kit includes a grease pack (10: 5 g and 10 g, 15: 10 g). Order with the following part number when only the grease pack is needed.
ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16
10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40, 50 2 x 4, 3.5 x 7, 4 x 10 10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40 to 50 4, 6 Nylon tube, 4, 6 Urethane tube Vacuum entry Thread dia.
Weight [g] Vane type Single vane Double vane Size 10 15 20 30 40 10 15 20 30 40 Rotating angle 90 180 270 90 180 270 90 180 270 90 180 270 90 180 270 90 100 90 100 90 100 90 100 90 100 Rotary actuator body 27 26 26 48 47 46 104 103 101 199 194 189 385 374 363 42 43 55 58 119 142 219 239 398 444 Flange assembly 9 10 19 25 9 10 19 25 Auto switch unit 15 20 28 38 43 15 20 28 38 43 Angle adjuster