Metric size Inch size Pilot port Model Port size 6 8 10 12 1/4" 5/16" 3/8" 1/2" ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04 M5 x 0.8 R 1/8 Rc 1/8 R 1/4 Rc 1/8 R 3/8 Rc 1/4 R 1/2 G 1/8 R 1/4 G 1/8 R 3/8 G 1/4 R 1/2 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/8 NPT 3/8 NPT 1/4 NPT 1/2 Note) Brass parts are all
AMR3000 to 6000 Series How to Order Adapter Assembly (Part number for one piece) 03 AMR 4 0 00 02 E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425
(mm) 4 6 7.5 9 H Outer layer thickness (mm) 1 1 1 1 Note) Black (B) D External layer color White (W) Red (R) MS Blue (BU) T Yellow (Y) Green (G) VMG 45 35 28 15 Min. bending radius (mm) Specifications Fluid Air/Water Max. operating pressure (at 20C) Burst pressure Inner tubing 1.0 MPa Refer to the burst pressure characteristics curve. 20 to +60C (Water: 0 to 60C) (No freezing) Nylon 11 PVC
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C HRS-R Series 3.3 Installation 3-19 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
R y 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2013 R Repeated from A to Z in alphabetical order 1 O Repeated from O to Z in alphabetical order, with O for January and Z for December 2014 S 2 P --2015 T 3 Q Fig. 1-1 Position of product label HRSH Series 1.4Product Label 1-3 HRX-OM-R026 Chapter 1 Safety Instructions 1.5 Safety Measures 1.5.1 Safety Instructions for Use Follow
LC1-1-S1 PC-98 (MS-DOS) LC1-1-W1 (Windows 95 Japanese) LC1-1-W2 (Windows 95 English) and LC1-1-R (dedicated communication cable) (Refer to pages 80, 81, and 85.)
fluid temperature [] 50Hz 60Hz Fig 9.5-1 Heating capacity(HRS050-A-20-R) HRS-R Series 9.4 Cooling capacity 9-7 HRX-OM-X027 Chapter 9 Documents 9.6 Pump capacity Fig 9.6-1 Pump capacity(HRS050--20-R) 9.6 Pump capacity HRS-R Series 9-8 HRX-OM-X027 Chapter 9 Documents 9.7 Compliance This system conforms to the following standards.
Aereo 081045 Santa Fe de Bogot, Colombia TEL: 1-424-9240 FAX: 1-424-9260 15-18-20 SMCs Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC
Nozzle size Coil tube Fitting Blow gun Recommended system Distance S coupler TCU0604-1-20-X6 KQ2H06-02S Up to 20 mm VMG1-02-01 KK4P-06H 1 TCU0604-1-20-X6 KQ2H06-02S Up to 40 mm VMG1-02-02 KK4P-06H 1.5 TCU0805-1-20-X6 KQ2H08-02S Up to 60 mm VMG1-02-03 KK4P-08H 2 TCU1065-1-20-X6 KQ2H10-02S Over 60 mm VMG1-02-04 KK4P-10H 2.5 Energy Saving Flow Air guns with an effective area around 6 mm2 are
r (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w e w q VQC1201 VQC1200 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r e q w e q w VQC1300 VQC1400 VQC1301 VQC1401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) VQC1500 VQC1501 r r 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w VQC1A01 VQC1B01 2(B) 4(A) 4
P) (Standard) Right side 1(P) (Option) NIL With locking hole R 3 (R) 1 (P) Port size OHSA standard (Occupational Safety and Health Administration Department of Labor) For safety control, OSHA rule requires energy sources for certain equipment be turned off or disconnected and that the device either be locked or labelled with a warning tag. 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Body size
SERIES 15 FLOW CHARTS 400 400 1/32 1/32 3/64 3/64 1/16 1/16 3/32 3/32 1/8 1/8 ORIFICE-INCH ORIFICE-INCH 100 100 50 50 PRESSURE PRESSURE DROP ROP PSI PSI 10 10 5 01 01 02 02 05 05 1 2 5 WATER FLOW-GPM SERIES 50 FLOW CHARTS 96 SERIES 70 FLOW CHARTS 400 400 SERIES 40 FLOW CHARTS 1/32 1/32 3/64 3/64 1/16 1/16 3/32 3/32 1/8 1/8 ORIFICE-INCH ORIFICE-INCH 100 100 50 50 PRESSURE PRESSURE DROP ROP
O 5/32 P 3/16 U 7/32 R 1/4 A 9/32 S 5/16 T 3/8 V 5/64 B 1/2 C 5/8 D 1 E 1 1/2 Y 3/4 F 2 W 3 D No Option Ports T Metering (1/32 1/8 orif.)
port size R 1 Model Part no.
OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.
(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.
Body type Plug-in type VVZS2000-10A-1 Non plug-in type VVZS2000-10A-2 Part no. Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Rc1 8 VVZS2000-R-01-1 VVZS2000-R-01-2 Body type Plug-in type VVZS2000-20A-1 Non plug-in type VVZS2000-20A-2 Part no.
NXT013-3 VO307K-1 2) 3) VEX322 VEX342 Rc A 1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17 VEX4-5 C 1/2 T NPTF 11 No.VEX-OMY0001 (2) () 3 2(A) 23(P2) 12(P1) a,b 12(P1),23(P2) (2) a 12(P1) 1(P)2(A)3 3(R) 3(R) b 23(P2) 2(A) 2(A)3(R)1 1(P) 1(P) 12(P1) 1 2 3 23(P2) 4 5 6 7 8 POM 9 -12No.VEX-OMY0001 () () 3(R) 2(A) 1(P) 1(P) 2(A) 3(R) () a b P1P2 2(A) 1(P)
25 61 (67) 76 (84) 81 (89) 86.5 30 35 40 40 9.5 12 12 15 20 22 24.5 24.5 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/2 3 Electrical entry Grommet Grommet (with surge voltage suppressor) Port size P Size Conduit terminal DIN terminal S R 1 2 Q 42 (47.5) 53.5 (61.5) 58 (66) 61 R 30 32.5 35 35 Q R 64.5 67 69.5 69.5 Q R Q 52.5 55 57.5 57.5 S T 99.5 102 104.5 104.5 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/2 28.5 (34) 39.5
Thread type Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Voltage Port size 1/8 (6A) Class 3 Class 2 Class 4 Symbol 01 02 03 04 06 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Please consult with SMC regarding other voltages.