O 5/32 P 3/16 U 7/32 R 1/4 A 9/32 S 5/16 T 3/8 V 5/64 B 1/2 C 5/8 D 1 E 1 1/2 Y 3/4 F 2 W 3 D No Option Ports T Metering (1/32 1/8 orif.)
J79W D RA1 C B W30 Size 30 MSU RA1 B W S 50 90 J59W C D Size 50 to 100 CRJ CRA1 Number of auto switches Built-in magnet S Nil 1 pc. 2 pcs.
center Manual override 1 2 3 4 5 24 VDC 12 VDC None Locking B type Locking C type Nil B C 240 VAC, 50/60 Hz Other Without auto switch B S 50 90 1 1 G CVRA1 B S 50 90 1 1 G S J59W CDVRA1 With auto switch Size Cushion Built-in magnet Auto switch With solenoid valve Nil C None With cushion For the applicable auto switch model, refer to the table below. 50 63 80 100 Mounting style Shaft type
Note) Note 1) Available with up to 16 solenoids.
s 0 to 999 times Minimum display unit 1 mm/s 0.01 s (0.00 to 99.99 s, 0.00 to 99.99 s) 0.1 s (100.0 to 999.9 s, 100.0 to 999.9 s) 1 time Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Measurement accuracy 20% or less 0.2 s or less Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA) Leak current 100 A or less Operating time 1 ms or less
Sensitivity 0.5% F.S. 1% F .S. 1.5% F .S. 2% F .S. Repeatability 0.5% F.S. 1% F.S. 1% F.S. 2% F.S.
Sub-plate gasket VP300-2-1P (Rc 1/8) VP300-2-2P (Rc 1/4) VP500-2-1P (Rc 1/4) VP500-2-2P (Rc 3/8) VP700-2-1P (Rc 3/8) VP700-2-2P (Rc 1/2) Mounting Screw Tightening Torques M3: 0.6 Nm M4: 1.4 Nm M5: 2.9 Nm VP300-17-1 VP344 SF4--50 VP500-17-1 VP544 VP700-17-1 VP744 How to Order Sub-plate VP 00 2 1 Series Port size Thread type VP744 3/8 1/2 VP544 1/4 3/8 VP344 1/8 1/4 3 5 7 P F N T VP344 VP544
H7BW 32 100 L R Number of auto switches Bearing type M L Slide bearing Ball bushing bearing Nil S n 2 pcs. 1 pc. n pcs.
(600mm lead wire) DIN connector DIN connector(Without connector) 2 01 1 8 1 8 H D DO Base mounted 02 1 4 1 4 Model Operating style Air operated External pilot solenoid P,A port , Port size Rc(PT) R port Model , 1 8 1 4 , 1 8 1 4 , 1 4 3 8 1 2 , 1 1 2 3 4 11 4 2 1 VEX1100 VEX1101 1 8 1 4 , VEX1200 1 8 1 4 , , VEX1300 1 4 3 8 1 2 1 1 2 , 3 4 , VEX1500 1, 1 VEX1700 1 4 1, VEX1900 VEX1201 VEX1301
Valve stations are numbered from station 1 on the D side. Indicate the valves to be mounted below the manifold part number, in order starting from station 1 as shown in the drawing.
Description 0 1 0 1 VY110 0 1 VY120 0 1 VY130 0 1 0 1 0 1 VY140 VY170 0 1 VY190 0 1 VY1D00 VY150 VY1B0 VY1A0 ITV B F G N AN120-M5 VEXA-18-2A VEX1-18-1A VEX3-32A VEX5-32A VEX7-32A VEX9-32A Bracket (With bolt, washer) IC VEXA-18-3A VEX1-18-2A G27-10-01 AN120-M5 G36-10-01 AN101-01 AN120-M5 G46-10-01 AN210-02 G27-10-R1-X207 Pressure gauge ITVH Pilot EXH port silencer ITVX Sub-plate and Base Gasket
(Including nut, screw, (spacer)) Applicable bore size (mm) 12 BQ-1 BQ-1 Cylinder series 40 BQ-2 BMU1-025 32 BQ-2 BMU1-025 80 BQ-2 50 BQ-2 BMU1-025 100 BQ-2 25 BQ-1 BMU1-025 140 BQ-2 160 BQ-2 125 BQ-2 BQ-1 20 63 BQ-2 BMU1-025 16 BQ-1 CDQ2 MDU RSDQ MK, MK2 CE1 CXT BQ-1 BQ-2 BQ-1 BQ-2 BQ-2 BQ-2 [Mounting screws set made of stainless steel] The set of stainless steel mounting screws (with nuts
0.85 0.51 45 1.50 0.31 3.91 0.09 1/8 NPT 0.50 1 1/4-12 1.19 1.20 0.81 45 1.91 0.59 5.11 0.12 1/4 NPT 3 Series NCM-A Dimensions ZB + STROKE LB + STROKE 0.50 W K A L ZC 2-ZD MM YC WA N KK UNF-2A B -0.003 0.000 PILOT Y WB D ACROSS FLATS NN UNF 2A Bore MM KK A B D E F GA GB K L 075 (3/4") 0.250 1/4-28 0.50 0.624 0.86 0.38 0.250 0.75 0.34 106 (1 1/16") 0.312 5/16-24 0.50 0.624 0.25 1.12 0.38
Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF and G(PF) thread types available. Various options also available.
Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF and G(PF) thread types available. Various options also available.
(Including nut, screw, (spacer)) Applicable bore size (mm) 12 BQ-1 BQ-1 Cylinder series 40 BQ-2 BMU1-025 80 BQ-2 32 BQ-2 BMU1-025 50 BQ-2 BMU1-025 100 BQ-2 25 BQ-1 BMU1-025 140 BQ-2 160 BQ-2 125 BQ-2 BQ-1 20 63 BQ-2 BMU1-025 16 BQ-1 CDQ2 MDU RSDQ MK, MK2 CE1 CXT BQ-1 BQ-2 BQ-1 BQ-2 BQ-2 BQ-2 [Mounting screws set made of stainless steel] The set of stainless steel mounting screws (with nuts
> D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, DE7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The above auto switches do not have internal contact protection circuits. 1.
> D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, DE7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The above auto switches do not have internal contact protection circuits. 1.
> D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, DE7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The above auto switches do not have internal contact protection circuits. 1.
VS4040-S-03 VS4040-S-04 DXT131-15P-06 DXT131-15P-10 DXT132-15-2P-12 DXT132-15-2P-14 XT021-9 DXT132-16 M6 x 25 with washer M8 x 35 3 8 1 2 3 4 VP450 Aluminum alloy Sub-plate !0 1 1 VP470 1 1 4 1 2 VP450 VP470 VP450 VP470 in part numbers are the same symbol for the thread type in How to Order. Gasket !1 Hexagon socket head screw VT3112-00G !2 Thread for mounting valve.