Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Non-standard Indicator: X, Body Surface Treatment: A (External: Hard Anodized - Internal: Oxalic Acid Anodized), Seal Material: N1 (EPDM (2101-80), Seal Replacement
Flange Size: 63, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Non-standard Indicator: X, Body Surface Treatment: A (External: Hard Anodized - Internal: Oxalic Acid Anodized), Seal Material: N1 (EPDM (2101-80), Seal Replacement
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: J (w/Indicator, Right Flange Surface), Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage Suppressor
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage Suppressor
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage Suppressor
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Right Flange Surface, Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator
HIGH VACUUM ANGLE VALVE, ALUMINUM, HIGH VACUUM VALVE, L45, 1.76000 lb
HIGH VACUUM VALVE. HIGH VACUUM ANGLE VALVE, ALUMINUM. 3.16000 lb. L45.
HIGH VACUUM VALVE. HIGH VACUUM ANGLE VALVE, ALUMINUM. 1.76000 lb. L45.
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without built-in magnet, Support bracket: Without auto switch mounting
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 50mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 25mm, Stroke: 50mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: 20mm, Stroke: 50mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 50mm, Stroke: 50mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: 32mm, Stroke: 50mm, Rod End Thread: G (Long Male Rod End)