193 186 18 203.5 196.5 19 214 207 11 Series SYJ300 C4 N3 Type 42 Manifold: Side Ported/SS3YJ3-42Stations -M5, [ ] for AC Grommet (G) For M5 C4 N3 For (Built-in one-touch fitting) 33.1 12 + + + + + Approx. 300 (Lead wire length) 30.7 (Light/surge voltage suppressor) 11.4 17.5 35.9 L1 L2 4 Manual override (4.4) 12 1/8 (P, R port) 8.5 2-4.5 (For mounting) 52.9 [55.1] P R P R 17.5 11.5 36
SW2-3,SW2-4 SW2-2 SW2-1 For the test operation select switchSW2-1, please refer to section 4 of LECSS2-T Operation Manual (Simplified edition). -36- 6.6.1 Positioning Mode In order to prevent accidental impact at the end of the stroke, operate the actuator at a low speed initially.
+0.5 0 8 7 6 5 36 +0.5 0 A Note) Alphabetical Index Length Measuring/ Counter R3.5 or less Note) Decide the length of A taking into account the size of terminal you use.
FU) (mm) AA AB A AV AW AX AY BA BB BC BD BE CB D DD DE DF DG FA FB FC FD H J JA JB Size 70 100 200 90 92 84 42 25.5 27 8 17 75 44.5 110 57 36 88h9 90h9 46H9 16 22H9 12.5 5 3.5 9 22 10.4 17.5 10.5 100h9 101 102 95 50 29.5 27 8 17 85 50.5 130 66 42 98h9 56H9 19 24H9 14.5 6 3.5 12 27 10.4 17.5 10.5 116h9 118h9 119 120 113 60 36.5 36 10 24 103 65.5 150 80 57 64H9 24 32H9 16.5 9 5.5 15 32 14.2
Manual override B P R R (35) 7 7 36 (2) 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14 14 15 (Bracket) 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 10 9 36 7.1 2 x M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2 x 3.2 1.5 1.5 22 7 8.2 2.5 (For manifold mounting) 2 x 1.8 2 x M3 x 0.5 (Pilot port) A B 11 1.5 17.5 (For
(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit
width across flats 36 ZSP A: Paddle short A: Paddle short B: Paddle middle B: Paddle middle Port size C: Paddle long C: Paddle long Port size ISA2 IS ZSM PF2 Dimensions Part no.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6.5 1.6 ZSP 20 41.5 ZS-24-A Bracket A View A ISA2 IS Bracket D ZSM A PF2 30 20 IF Data 20 45 55 4.2 4.5 40 11.5 15 7.2 7.5 1.6 41.5 35 22 ZS-24-D Bracket D View A Cutting dimensions for panel mounting 43 or more Panel mount 0 +0.5 36 42.4 7.8 25.4 0 +
Dimensions (Orifice Size: 10 mm) Normally Closed: VXP2130 Grommet: G Conduit: C (67) (52) 20 23 (67) (52) 20 39 270 10 290 10 G 1/2 VC (5.5) (2.3) (2.3) (5.5) VDW 80 86 63 69 66.5 73.5 80 86 71 77 (33) 36 (33) 36 (27) 30 VQ (7.5) (27) 30 (7.5) Bracket 11 14 11 14 VX2 IN OUT IN OUT Bracket 24 26 50 2-Rc 1/4, 3/8, 1/2 (28) (28) 24 26 50 2-Rc 1/4, 3/8, 1/2 VX 22 28 40 22 28 Courtesy of Steven
41 S 50 52 T 32 38 U 54 57 V 66 69 W 30 36 X 71 74 Y 101 104 Z 65.5 71 55 62 26 31 17 19 19.5 21 33 39.5 26 31 35 43 23.5 27 39.5 43.5 57.5 65.5 35 41 26.5 29 41.5 48 50 55 VV2CA3 VV2CA4 8 Series VCA Manifold Exploded View Series VCA20 Description No. 1 2 3 4 Part no.
Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. Connection and Electrical Circuit Warning Manual Override Without an electric signal for the solenoid valve the manual override is used for switching the main valve. The VQZ series features non-polar solenoids.
) 44 (38) 46 (33) 42 (35) 48 (35) 44 (37) 47 (34) 43 (36) ZPY40 49 (35) 50 (37) 49 (35) 44 (38) 46 (38) ZPY50 ( ): Figures for female thread connections.
13.2 52.2 7.1 33.7 17 19 AS3001F-06T 6 12.8 59 7.4 45 17 56 AS2051F-05T 3/16" 11.4 52.2 6.2 34.9 16.5 35 AS3001F-08T 8 15.2 64.4 8.2 45.8 18 60 AS2051F-07T 1/4" 15.5 7 1.5 13.2 54.4 7.1 35.7 17 33 20.6 9.5 1.5 AS3001F-10T 10 18.5 71.6 9.8 47.3 21 64 AS2051F-09T 5/16" 15.2 59.8 8.1 36.7 18 36 AS3001F-12T 12 20.9 76 11 48.5 22 68 AS3001F-07T 1/4" 13.2 59 7.4 45.2 17 56 AS4001F-10T 10 18.5
21 33.9 43.2 18.5 13.2 10 1/4" 40.4 35.4 34.4 29.4 18.5 34 18.5 AS321FG-02-06 AS221FG-N02-09 27.2 36.4 60 17 27.8 39.3 12.8 15.2 6 5/16" 20 21 36 AS321FG-02-08 AS221FG-N02-11 33.9 43.2 63 18.5 29.5 41 15.2 17.9 8 3/8" 23 43.8 48.8 21.8 19 42.8 37.8 R 1/4 AS321FG-02-10 AS321FG-N02-07 27.8 39.3 67 21 31.8 43.3 18.5 13.2 10 1/4" 17 60 NPT 1/4 AS321FG-02-12 AS321FG-N02-09 19 21.8 29.5 41 69
C Q + Stroke Shock absorber Shock absorber RB0805 Side plate Section IF (CY1L6) (mm) A B D d C EA FA EB Model G HP J JK FB GP H HB HG HI HO HS HT HA CY1L6 CY1L10 7.6 8 3 6.5 7 M4 x 0.7 6 26 6.5 36 27 10 11 9 25 14 16 5 12 10 4 8 8.5 M5 x 0.8 6 3 12 7.5 33 9.5 5 50 34 17.5 14.5 13.5 33 21.5 18 6 PA (N) (NA) (NB) RW Q Z W tb ta T PB MM NN M L QW LD Model CY1L6 CY1L10 TT PW 12 54 68 56 10
150 H J K M XYC-50 XYC-63 XYC-80 178 209 268 29 36 44 10.5 9 9 78 99 116 487 Stainless steel High Vacuum Angle/In-line Valve 2 Stage Control, Single Acting/Bellows, O-ring Seal XMD, XYD Series PAT.
No. 11 12 13 14 15 16 17 18 19 20 Exploded View y VVQ1000 51A C8 L Dimension 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 Port size L Dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 C8 8 One-touch fitting N9 5/16" One-touch fitting No. 31 32 33 34 35 36 37 38 39 40 L Dimension 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 33 Exploded
Number of pages has been increased from 20 to 36. YP Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
ZP3EA-S2 [Weight: 7.6 g] 24 47 15 29 4 20 36 Applicable pad part no. ZP3E-63UM ZP3E-80UM ZP3E-100UM ZP3E-125UM ZP3E-63BM ZP3E-80BM ZP3E-100BM ZP3E-125BM Applicable pad part no.
18 36 M12 x 1 M12 x 1 M12 x 1 Vertical 36 Width across flat 14 Vertical Width across flat 14 Width across flat 14 With Buffer: Vacuum Inlet With Buffer: Vacuum Inlet 10 5 15 10 5 15 10 5 15 Lateral Lateral 2 2 2 With Adapter: Vacuum Inlet 17 16 11.4 1.8 13 8.4 1.8 11 10 6 1.8 With Adapter: Vacuum Inlet 14 Lateral With Buffer: Vacuum Inlet Construction Adapter Applicable Pad List ZP3-T10B