Power/Voltage At the Rated Voltage Model Starting Power (W) Current (A) Power (W) Current (A) Holding G/C/D/T, P5G 1.5 36 4.8 14.8 10 4.9 2.3 5.3 20 13.5 6.7 3.0 0.38 0.35 0.27 0.11 0.10 0.5 0.46 0.36 0.15 0.12 50 Hz 60 Hz 50 Hz 60 Hz P1G 0.47 30.5 XLS-16P2G 0.24 30 G/C/D/T, P5G 2.0 47 50 Hz 60 Hz 50 Hz 60 Hz P1G 0.62 42 XLS-25P2G 45 0.35 XLA Construction/Operation XL XL Internal control

Hs A Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-F9 D-F9V D-F9W D-F9WV D-A9V D-F9BAL D-F9V D-F9WV D-A9 D-A9V Bore size (mm) D-F9BAL Bore size (mm) Hs Hs Hs 20 22 22.5 25 B A B A A B 20 25 36 6.5 37 7.5 33 3.5 24.5 27 24 25 32 41 8.5 9.5 38 5.5 42 27 29 26.5 32 40 8 9 43 5 44 40 32.5 30 30.5 40 50 10.5 49 7.5 50 11.5 46 36 36.5 38.5 50 63 48 13.5 49 14.5 45

REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Bore size (mm) RHC 10 35 35.5 45 44.5 40.5 39.5 MK(2) 15 34.5 35 62.5 62 40 57 20 64 64.5 50 49.5 69.5 44.5 RS Q G 25 44 44.5 71 70.5 49.5

REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800

D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5

Minimum Stroke for Auto Switch Mounting (mm) No. of auto switches mounted 2 Different sides Auto switch model Same side n Different sides 1 Same side D-C7 D-C80 15 50 + 45 (n 2) 50 10 n 2 2 15 + 45 ( ) (n = 2, 4, 6) D-H7 D-H7W D-H7BAL D-H7NF 15 60 + 45 (n 2) 60 10 D-C73C D-C80C D-H7C n 2 2 15 + 50 ( ) (n = 2, 4, 6) 65 + 50 (n 2) 15 65 10 n 2 2 D-B5 D-B64 15 + 50 ( ) (n = 2, 4, 6) 15

style D-A73C, D-A80C, D-J79C 25, 32 40, 50, 63 22.6 30.5 HS HS HS Auto switch D-A79W, D-F7WV, D-F7V D-F7BAVL 25, 32 40, 50, 63 22 30.5 HS Auto switch D-P5DWL 40, 50, 63 20 HS Auto switch 7-8-20 21 Series MDU With Auto Switch Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Proper Auto Switch Mounting Position Auto Switch Mounting Height Auto

Symbol Auto switch positioning and mounting 40 50 63 2 pcs. 1 pc. "n" pcs. Model A B Same side Same side 8 0 0 D-P7, D-P8 25 25 25 50 + 65(n-2) 50 50 D-P7, D-P8 D-P5 Approx. Hs 45 49 54.5 Approx. Ht 28 28 28 A B 3 4.5 4.5 26 27.5 27.5 D-P5 Approx. Hs 46 50 56 Approx.

Mounting bolt C D Mounting bolt Mounting bolt D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63

(mm) Auto switch model Hw 23 Ht 15 Hv 10.5 D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C 23 15 10 22 23 23 24 15 17.5 15 17.5 9 17.5 14 16 Note 2) 2 magnets for auto switches are installed in the housing. 8-26-16 15 Series CXWM Slide Unit: Build-in Shock Absorber Slide Bearing Type 16 Basic Type: CXWM16Stroke/50

D-F5LF (2 color indicator) D-A53 D-A54 D-A56 D-A64 D-A67 D-A59W (2 color indicator) Single rod Series MNB 40 50 63 80 100 25 to 500 Cylinder with Lock Series MNB Tie-rod mounting type 25 to 600 Double acting Double rod Series MNBW 25 to 700 Feature 2 Cylinder with Lock Double Acting: Single Rod Series MNB 32, 40, 50, 63, 80, 100 How to Order MNB L 50 100 D Standard type With auto switch

Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 20mm, Thread: TN, Stroke: 50mm, Option: None, Lock Style: P (Air Pressure Lock-up (Pressure Lock)), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs.

Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 20mm, Thread: TN, Stroke: 50mm, Option: None, Lock Style: Air Pressure Lock-up (Pressure Lock), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket

Mounting bolt C D Mounting bolt Mounting bolt Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63

Mitsubishi Electric Corporation Yaskawa Electric Corporation Nil G R Y Brake 50W 100W 200W 1 2 3 None With brake Nil K Power supply voltage Stroke 100/110VAC 50/60Hz 100/115VAC 50/60Hz 200/220VAC 50/60Hz 200/230VAC 50/60Hz Without motor Lead screw lead 1 H B C F A D E 8mm 12mm 20mm 5mm 10mm 25mm 40mm 2 0 Lead screw type The tables above show the definition for each symbol only and cannot

(Spring return/Spring extend) MU Minimum Stroke for Auto Switch Mounting Operating Range D(mm) D-A7H, D-A80H D-A79W D-F7, D-J79 D-F7W, D-J79W D-F7BAL, D-F7NTL D-F79F Auto switch model Bore size (mm) 25 -X D-A7 D-A80 D-A73C D-A80C No. of auto switches mounted 32 40 50 63 D-P5DWL D-F7V D-J79C D-F7WV D-F7BAVL D-A7/A80 D-A7H/A80H D-A73C/A80C 2013 13 13 13 13 Same side 75 Different sides 20 Data

) (n = 2, 4, 6) Note 3) D-H7 D-H7W D-H7BA D-H7NF (n 2) 2 70 + 45 (n 2) 25 + 45 70 25 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-C73C D-C80C D-H7C (n 2) 2 80 + 50 (n 2) 30 + 50 80 5 30 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-B5 D-B64 D-G5 D-K59 (n 2) 2 70 + 50 (n 2) 25 + 50 5 70 25 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 75 + 50 (n 2) 30 + 50 D-B59W 10 75 30 (n = 2, 3, 4,

Voltage Symbol Voltage Applicable size 3E 4E 6E 8E 11E 15E1 Refrigerant R407C (HFC) IDF D 10 Single-phase 100 VAC (50 Hz) 100/110 VAC (60 Hz) V V V V V V 20 Single-phase 200 VAC (50 Hz) 200/220 VAC (60 Hz) V V V V V V 23 Single-phase 230 VAC (50 Hz) V V V V V V Refrigerant R134a (HFC) IDU E Options Symbol *1 Nil C G K L M R S T V Moderate pressure specification *2 With Chinese labels and

50 12 Series RQ Auto Switches/Proper Mounting Positions and Height for Stroke End Detection 32 to 50 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NT D-F7BAL D-A7 D-A80 Approx.

F 4-9.5 F 4-8 4-6 3-6.5 4-5 G 3-4 Y 3.5 Y 6 E E E Y 8 10 6 34 40 18 C C C A B D A A B D B D Dimensions Dimensions Dimensions (mm) (mm) (mm) A B C D E F Y A B C D E F G Y A B C D E F Y Model Model Model ZP40HB ZP63HB ZP100HB 40 41.4 28.4 43.2 20.5 30 13 63 65.1 45.5 67.6 31.5 50 4.5 21.5 100 103.1 68.6 106.7 47.5 80 35.5 ZP50HB ZP80HB ZP125HB 50 51.9 35.7 54 24 40.5 16.5 80 83 58.4 85.1 37