Unit psig/bar MPa Code r e No code MPA Sample Order Number Port qIN wOUT eGauge port (Inlet) rGauge port (Outlet) w q AZ1402TS e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 3) Pressure gauge unit MPa or psig/bar selectable.
(page 84) 5 R/W 5th letter U8 0 Y 2420 0x0974 6 R/W 6th letter U8 0 Y 7 R/W 7th letter U8 0 Y 8 R/W 8th letter U8 0 Y 9 R/W 9th letter (right end) U8 0 Y 1 st dot (left end) U8 0 Y 1 R/W 2 R/W 2nd dot U8 0 Y 3 R/W 3rd dot U8 0 Y Line name dot 4 R/W 4th dot U8 0 Y 0: oFF (dot OFF) 1: on (dot ON) 5 R/W 5th dot U8 0 Y 2430 0x097E 6 R/W 6th dot U8 0 Y 7 R/W 7th dot U8 0 Y 8 R/W 8th dot U8 0 Y
) 0x1F88 (8072) 1 R Rated range lower limit N S16 2 R Rated range upper limit N S16 3 R Measurable range lower limit N S16 0x1F9A (8090) 0x1F9B (8091) 0x1F9C (8092) 0x1F9D (8093) 4 R Measurable range upper limit N S16 5 R Settable range lower limit N S16 6 R Settable range upper limit N S16 1: "R" means Read and "W" means Write.
Note 5) 1000 1270 2400 Applicable circuit breaker capacity Note 6) (A) 10 IDG (sensitivity current 30 mA) Condenser Forced air-cooled IDK Refrigerant R134a (HFC) R407C (HFC) Symbol N R 1 (male) R 11/2 (male) NPT 1 (male) NPT 11/2 (male) NPT 2 (male) Thread symbol and size AMG Symbol Nil R 2 (male) Symbol N 3/8 inch Drain tube O.D.
-100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD
R FOUNDATION fieldbus and Profibus Uo(Voc) = 5.0V, Io(Isc) = 17.8mA, Po = 22.2mW, Co(Ca) = 10nF, Lo(La) = 10H. X II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc II 3 G Ex ic IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc II 3 D Ex ic IIIC T90 C...T120 C Dc Temperature range: T4: -40 to +85 C; T5: < +75 C; T6: < +60 C. Arctic temperature option.
# 0 0 D R [CR] No. No. + 3 3 3 3 3 3 + 1 1 1 1 1 1 2 2 2 2 2 2 C (O/H/C) # 0 0 D W [CR] No. No. + 3 3 3 3 3 3 + 1 1 1 1 1 1 2 2 2 2 2 2 C (O/H/C) # 0 0 D W [CR] No. No. )0 ,+O H C 29 - # 0 0 P R [CR] No.
Basic type Select type Model VEX5504 06 10 VEX57-10 12 VEX59-14 20 P1 P1 VEX VEX Description Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Air operated External pilot solenoid valve 3(R) 3(R) Pressure gauge 1(P) 3(R) 3(R) 1(P) P2 P2 P3 P1 P1 3(R) 3(R) 3(R) 3(R) 1(P) 1(P) P2 P2 Note) With this valve, the port 3(R) is a supply port and port 1(P) is an exhaust port. 2441
This may cause damage to the machinery. ) m m ( e z i s e r o B e v l a v n o i h s u C s t a l f s s o r c a h t d i W h c n e r w n o g a x e H 0 5 , 0 5 , 2 3 7 4 2 1 C 0 1 2 3 B M 5 . 2 5 . 2 y e k h c n e r w n o g a x e H 0 0 1 , 0 8 , 3 6 0 5 2 1 C 0 1 3 6 B M 4 4 y e k h c n e r w n o g a x e H Mounting & Piping 2. Be certain to activate the air cushion at the stroke end.
R 30 - PNP type (LECPAP-) Power supply for pulse signal Positioning unit side Inside of the driver Current limiting resistor R NP+ <3> 1k NP<4> 120 Current limiting resistor R PP+ <5> 1k PP<6> 120 Caution Be sure to install a current-limiting resistor R according to the pulse-train signal voltage.
9 i@2 q r y #0$0 $2 w $3 #8 @9 A C CJ1 CJP CJ2 B CM2 Section A !2 !2 !22 $1 e $8 o $7!1@1!6 @5 u!0 $6 #7 #6 $4@8#9 @6 #4 C85 with through piston rod C76 100 80 63 50 40 32 CG1 #1 #2 Section B Section C MB MB1 80, 100 80, 100 CP95 Description Material Note Parts list Description Material Note Parts list No. q w e r t y u i o !
Please change the parameter in the initial setting. * For LECSS2-T, please set the electronic gear with PC, PLC etc. in your application. -24- Recommended Parameter Values [LEY] LEY25T6 LEY25DT6 LEY32T7 LEY32DT7 / LEYG25T6 / LEYG25DT6 / LEYG32T7 / LEYG32DT7 Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Initial value Recommended value Parameter *1,*2 Para.
(Page 77) 8000 0x1F40 0 R 8010 0x1F4A 0 R Flow rate PD conversion equation: b F32 N 8020 0x1F54 0 R Flow peak value S16 N 0x0 to 0x1068 (0 to 4200) 8030 0x1F5E 0 R Flow bottom value S16 N 8060 0x1F7C 0 R Accumulated PD conversion equation: a F32 N Measurement related 8070 0x1F86 0 R Accumulated PD conversion equation: b F32 N Refer to "Inclination and intercept to the unit specification".
(between FE and all accessible terminals) Insulation resistance 10 M or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z Vibration
Stroke + 126 3.3 24 1 5 3 5.8 8 3 21 59 F 5H9 +0.030 0 depth 5 T-slot dimensions (2/1) 29.5 5H9 +0.030 0 depth 5 6 T-slot 4-M5 x 0.8 (for body mounting) thread depth 8 (11.5) 38 E Refer to page 299 for mounting.