When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Accuracy: Basic Type, Size: 63, Motor Type: T7 (200W Output, Absolute Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 500mm, Motor Option: B (Lock), Cover: w/o Cover, Cable Type: R (Robotic, Flexible), Cable Length: 5m, Driver Type: 92 (LECSN2-T*-9, 200~240V, Absolute, EtherNet/IPâ„¢ Card), I/O Connector: 1 (1.5m)
The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Motor Type: T6 (AC Servo Motor, Absolute Encoder, Output 100W), Lead: C (LEY25 3mm; LEY32 4mm; LEY32 Top Mount 5mm), Stroke: 150mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: R (Robotic Cable - Flexible Cable), Cable Length: A (10m), Driver Type: 92 (LECSN2-T-9, 200~240V, Absolute,
CYL, B, 200, Rod Length. 0.92700 lb. E30.
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 3 (Bar)
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable COMPACT CYLINDER. Compact Cylinder, CQ2-Z. 323.00000 lb. 493.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C 4/5 PORT SOLENOID VALVE. 5 port pilot operated valve. 2000.00000 lb. I50.
Piping: 1 (Bottom Direction), Body Color: W (Urban White), Piping Type: Rc, Connection Size: 12 [S Coupler Plug (Rc Type Only)], Nozzle: 32 (Copper Extension Nozzle 300mm Length, VMG1-06-200-300)
Series: NCA1 (Standard), Mounting: J (MT2, Head trunnion), Bore Size: 200 (2"), Stroke: 1200 (12")
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C 4/5 PORT SOLENOID VALVE. 5 port pilot operated valve. 1250.00000 lb. I50.
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC 3 PORT SOLENOID VALVE. Direct Op 3 Port Solenoid Valve, COM. 640.00000 lb. K44.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C 4/5 PORT SOLENOID VALVE. 3000 SERIES