SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-02-AB"

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

NT-02 NT-03 NT-04 13 15.0 12.5 M8 x 1.25 5 M10 x 1.25 17 19.6 16.5 6 M14 x 1.5 22 25.4 21.0 8 2 x LD Mounting Nut Applicable pin part no. Part no.

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

10 One-touch Screw-in One-touch 01 02 02 Screw-in Screw-in Screw-in ZH13DA09 11 11 One-touch One-touch One-touch 09 N02 11 One-touch Screw-in One-touch N01 N02 N02 Screw-in Screw-in Screw-in ZH15DA08 10 10 One-touch One-touch One-touch 08 03 10 One-touch Screw-in One-touch 02 03 03 Screw-in Screw-in Screw-in ZH15DA09 11 11 One-touch One-touch One-touch 09 N03 11 One-touch

BMA2-020 BMA2-025 BMA2-032 BMA2-040 BMA2-050 BMA2-063 D-H7 D-B5/B6 BA-01 BA-02 BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-G5/K5 20 to 63 Mounting screws set made of stainless steel The following set of mounting screws made

AC adapter (Without AC cord) 03 Power supply cable (For 24 VDC wiring) N None Symbol Type 01 Standard nozzle 02 Bypass nozzle*3 *1 The AC adapter body and the power supply cable (For AC adapter) come as a set.

Precautions FH150-02 to 04 q Mounting Confirm IN and OUT before mounting.

How to Order Internal pilot operated relieving type regulator AR 25 4 BG 02 Semi-standard Nil Flow direction: Right to left None (Standard) Regulator R Body size Port size Accessory 4 6 8 9 1 2 1 Symbol 1 Description Applicable model 02 03 04 06 10 12 14 20 1 4 Nil 2 1 8 3 B With bracket AR4 5 to 6 5 AR 25 AR 35 2 1 2 3 4 Gauge G46-10-02 G46-2-02 G Regulating pressure range 1 G46-P10-02-X30

OUT() DC(-) DC(+) PSE57-02-28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -11No.PS-OMT0005CN-A (A/D ) () 20 2030 -12No.PS-OMT0005CN-A PSE575 PSE576 PSE577 02 MPa 05 MPa 010 MPa 5MPa 12.5MPa 30MPa 5%F.S.(25 ) PSE57-02 PSE57-02-28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 ) 2.5F.S. 0.5F.S. 0.5F.S.(25 ) IP65 AC500V 1 100M(DC500 V) -1060 -2070 ()

A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

Common exhaust: VV3P3-41Stations 1-02 (G) (E) (T) (D, Y) N.C. N.O.

-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214

20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.

Tap Water (as Facility Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water 2. Operation and suspension frequency should not exceed 10 times per day. Frequently switching between operation and suspension may result in the malfunction of the refrigeration circuit.

Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 Although speed adjustment is possible with

20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.

1 to 30 psig (0.007 to 0.2 MPa) 1 to 60 psig (0.007 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) Bonnet option 02 06 10 Bonnet Standard Panel installation 4) Code No code P Connections (Inletq, Outletw) 4) Panel mounting hole: dia. 1.56 inch (39.6 mm).

Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400