0 to 50C (with no condenssation) Fluid temperature Note 3) 11 l 20 l Volume of valve chamber Note 4) Free Mounting orientation Enclosure IP40 or equivalent Weight 30 g 34 g (Without sub-plate), 42 g (With sub-plate) Rated voltage 12, 24 VDC Note 5) Allowable voltage fluctuation 10% of rated voltage Body ported type (Tubing type) Type of coil insulation Class B 2.5 W at inrush, 1 W at holding
(14 to 122F) 5 to 50C (23 to 122F) Note 1) Note 1) Ambient and fluid temperature 1 (P) 5 (R1) 3 (R2) Lubrication Not required Manual override Non-locking push type/Slotted locking type (tool required) optional 3 position exhaust center (A) 4 (B) 2 Impact/Vibration resistance 150/30 m/s (45.7/9.1 in/s) Note2) Enclosure Dust proof (IP65 type available) Rated coil voltage 12VDC, 24VDC, 100VAC
Standard Specifications Valve construction Rubber seal Metal seal Fluid Air, Inert gas Air, Inert gas 0.7MPa (High pressure type: 0.8MPa) Max. operating pressure Single 0.15MPa 0.1MPa Minimum operating pressure Double (latching) 0.18MPa 0.18MPa 3 position 0.2MPa 0.1MPa 10 to 50C Note 1) Ambient and fluid temperature Lubrication Not required Push type/Locking type (slotted type, knob type)
If it is unavoidable, install a cover, etc., for protection. 1 Places where the ambient temperature exceeds -5 to 50C range.
Air, inert gas Fluid 0.6 MPa Maximum operating pressure 0.3 MPa Minimum operating pressure 5 to 50C Ambient and fluid temperature Not required Lubrication Manual override Non-locking push type / Lock type (tool type) Push-lock type Non-locking push type / Lock type (tool type) Rated coil voltage DC12, 24 V DC12, 24 V, AC100, 110, 200, 220 V DC 1W 1W 0.5W 100 V AC 0.6VA (6mA) 0.5 VA (5 mA)
anti-chattering function) Output short circuit protection Display 2% F.S. 1 digit or less (at ambient temperature of 25 3C) Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5V 5% F.S. or less (in rated pressure range) Linearity: 1% F.S. or less Output impedance: Approx. 1k No-voltage input (reed or solid state), input 5ms or more IP65 Operating: 0 to 50C
Supply/Release Valve Specifications Pilot type 3 position 3 port solenoid valve Valve type Closed center Type of actuation Series ZYY3000 Air Fluid 0.2 to 0.7MPa {2 to 7.1kgf/cm} Operating pressure range 5 to 50C Ambient and fluid temperature 10 to + 10% Allowable voltage fluctuation Grommet : G, H L type plug connector : L, LN, LO M type plug connector : M, MN, MO Electrical entry 0.5W
2% F.S. or less (0 to 50C, based on 25C), ?
3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance410 g3/8
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
10% or less)150 mA or lessIP650 to 50C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?
10% or less)150 mA or lessIP650 to 50C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?
; rubber seal -5 to 50C, VALVE, SGL SOL, PLUG-IN, VALVE, VQ5000 VALVE, SOL 5 PORT, 2E, VQ5000 BASE MT NO SIZE RATING, 2.42676 lb
(kg)Pressure typeVEP31413 8 , 1 2 , 3 4Air (Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.05 s or less3% F.S.3% F.S.0.5% F.S.3% F.S. or lessNot required (Use turbine oil Class 1, ISO VG32, if lubricated.)1.4
; rubber seal -5 to 50C, Optional IP65 enclosure, SHUT OFF VALVE, VALVE, VV5Q41 NO SIZE RATING, .67739 lb