SMC Corporation of America
Elite Part Number Search
Search Results "VVEXB-2-6-01T"

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less

Series LVN Flow characteristics LVN20 LVN30 LVN40 4.5 8 14 4 7 12 3.5 6 10 MPa 3 5 Flow rate Flow rate Flow rate 8 2.5 4 0.03MPa 2 6 3 1.5 4 2 1 P0.01MPa P0.01MPa P0.01MPa 2 1 0.5 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 Needle rotations Needle rotations Variations Applicable tubing outside diameter diameter Series (water) 4 6 8 10 12 1/8 3/16 1/4 3/8 1/2 4.4 0.5 LVN20 8 1.4 LVN30 10

temperature Nylon, Soft nylon, Polyurethane, FEP, PFA Air 0 to 1 MPa 5 to 60C (No freezing) 5 1 3 1 2 2 1 4 2 3 2 1 AS 2 1 3 1 2 Nylon Polyurethane AS-FE 13.1 mm2 26.1 mm2 18.0 mm2 41.5 mm2 29.5 mm2 58.3 mm2 13.1 mm2 Effective area AB 46.1 mm2 12 Residual pressure release effective area 1.8 mm2 KE KE Easy operation with a push button.

6: 1 pc. each FGDT FGDF u, o, !1, !2, !3, !4, !5, !6, !7 : 1 pc. each Note) Only the FGD-CA003 and CA005 includes !8 element guide in the set.

Voltage AC125V 2 2 4 4 15 10 15 10 AC250V 1.5 1.5 3 3 15 10 15 10 DC8V 1.5 2.5 3 5 15 15 15 15 DC14V 1.5 2.5 3 5 15 10 15 10 DC30V 1.5 2.5 3 5 6 5 6 5 DC125V 0.3 0.05 0.3 0.05 0.5 0.05 0.5 0.05 DC250V 0.2 0.03 0.2 0.03 0.25 0.03 0.25 0.03 JIS Symbol Construction Precautions Component Parts Be sure to read before handling.

(Produced upon receipt of order) Note 2) Minimum stroke available without auto switch or with one auto switch is 15 mm and minimum 25 mm for with 2 auto switches. Note 3) For 2 or more auto switches with stroke less than 25 mm (minimum 15 mm), consider -X431 (2 switch rails).

) 4 47 42 (Non-locking) Manual override VlA 30 24.5 37 23 20 3 11.5 3.5 4 11 2.6 2(Mounting holes) 18 (Piping port) 4-Rc(PT)1/8 19.5 46.5 25 SlA 1.8 (Bleed port) With filter (80 Mesh) 2.3 46.5 33.5 21.5 5-M5 X 0.8 (Piping port) VlA 8.5 6 6 15 17 17 24 32 R1 P 45.5 1.8 (Bleed port) With filter (80 Mesh) R2 21 VM/VR VH 2 position double: SYJA5220-M5 2 position double: SYJA5240-01 (Mounting

Ozone resistant Example 1) 0.4 MPa setting with 6 stations IRM10-6G-16 Example 2) 0.2 MPa setting 2 pcs., 0.4 MPa setting 2 pcs., 0.8 MPa setting 1 pc. with 5 stations IRM20-5G-021221 4 For High/Low Temperature Environments Standard model no. T Stations Accessory (Pressure gauge) For high/low temperature environments 2 2 stations Nil None ... ...

0.8 to 37.1 1.8 to 92.7 4 to 186 8 to 371 Instantaneous CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Setting/Display flow range flow CO2 0.8 to 18.5 1.8 to 46.3 4 to 93 8 to 185 CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Min. setting/display unit 0.1 CFM x 10-2 0.1 CFM x 10-2 1 CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3

Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. -3- 1Specification High performance Battery-less absolute encoder LESYH*(D,R,L)G* LESYH LESYH LESYH LESYH LESYH LESYH LESYH Model 8*GA 8*GB 8*GC 16*GA 16*GB 25*GA 25*GB Stroke[mm] 50,75 50,100 50,100,150 Max.work load[kg] 2 8 12 Horizontal Vertical 1.5 3 6 6

SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

No.MH*-OMY0001 / / MHM-16D* MHM-25D* MHM-32D* MHM-50D* 1. 2. 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 3. 4. 5. 5-1 5-2 5-3 -2- (ISO/IEC) (JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements)

A unit label is attached. 67 2 settings PNP open collector 2 outputs 2: Fixed unit: MPa Option Part no.

Value/Range SetPoint1 bit(16) 16 bit 3 Y 3 1 R/W 0x003C BDC1 2 R/W SetPoint2 bit(0) 16 bit 3 Y 3 (60) Logic bit(24) 8 bit 0 Y 4 1 R/W 0x003D 2 R/W Mode bit(16) 8 bit 0 Y 5 BDC1 (61) 3 R/W Hysteresis bit(0) 16 bit 10 Y 1 to 400 SetPoint1 bit(16) 16 bit 3 Y 3 1 R/W 0x003E BDC2 2 R/W SetPoint2 bit(0) 16 bit 3 Y 3 (62) Logic bit(24) 8 bit 0 Y 4 1 R/W 0x003F 2 R/W Mode bit(16) 8 bit 0 Y 5 BDC2

Specialty Regulators NAR Series Pressure Regulator NAR425, 435, 625, 635, 825, 835, 925, 935 s n o i t a c i f i c e p S l e d o M 5 2 4 R A N 5 3 4 R A N 5 2 6 R A N 5 3 6 R A N 5 2 8 R A N 5 3 8 R A N 5 2 9 R A N 5 3 9 R A N e z i S t r o P 2 / 1 8 / 3 4 / 1 1 4 / 3 2 / 1 1 4 / 1 1 2 ) a P M ( g i s p e r u s s e r p f o o r P ) 5 . 1 ( 0 2 2 e r u s s e r p g n i t a r e p o . x a

System error (Er5, 6, 7, and 8) is indicated. (1)Bring the pressure back (1)Check if the pressure gets over within the set pressure range. the upper limit of the set pressure range. 6 The display Applied pressure is over the upper limit (---). (2)Take measures to prevent shows "---". (2)Check if foreign matter got into foreign matter from getting into the piping.

L O L ZX G H F K ZR J ZM ZH E D I A ZU B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL 2-4.5 ZY ZQ A B C D E F G H I J K L Model 4 ZFC100-04 ZF 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 ZP 1/4" ZFC101-07 6 ZFC200-06 ZCU 8 ZFC200-

If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 7 3 Position Cylinder Series RZQ Construction 13 24 21 3 2 1 6 4 8 7 10 19 22 20 12 23 11 9 5 23 18 14 16 17 15 22 Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 Note Note Description Material Description Material Hard anodized Aluminum alloy