Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Elbow Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Elbow Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø4 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø4 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø6 One-touch Fitting, Elbow Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø6 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -
Operation and Mounting 2.1 Air Supply -P. 5 2.2 Operating Environment -P. 6 2.3 Design -P. 6 2.4 Mounting and Installation -P. 8 2.5 Piping -P. 10 2.6 Speed Control -P. 11 2.7 Shock Absorbing Mechanism -P. 11 2.8 Directional Control -P. 12 2.9 Mounting of Auto Switch -P. 13 3. Maintenance and Inspection 3.1 Inspection -P. 14 3.2 Maintenance -P. 14 3.3 Replacement Parts -P. 14 4.
VV307-01-3--F P = 26 (Applicable cable O.D.)
type (Centralized piping type) CQ2-Z Long stroke Double acting, Single rod w-1 From P. 985 RQ RQ Double acting, Single rod Compact cylinder with air cushion w-3 From P. 771 CVM5 Double acting, Single rod CV3 CV Valve mounted air cylinder Double acting, Single rod w-3 From P. 812 CVS1 Double acting, Single rod Applicable to 20 to 100 MGPM-Z Double acting w-2 From P. 432 Applicable to 20 to
Depending on the piping volume (piping length and diameter), if the pressure just before the supply (P) port falls below 0.5MPa, the performance such as vacuum pressure may reduce. Raise the upstream pressure, and the pressure just The pressure just before the supply (P) port is low. before the supply (P) port becomes 0.5MPa.
PE Compact P pressure sensor Supply valve PSE541-R04 P Circuit diagram V -15No. TQ1230001-OM101-D 4.4. URCap Installation and basic setting 1.
Depending on the piping volume (piping length and diameter), if the pressure just before the supply (P) port falls below 0.5MPa, the performance such as vacuum pressure may reduce. The pressure just before the supply (P) port is low. Raise the upstream pressure,and the pressure just before the supply (P) port becomes 0.5MPa.
P.24 P.36 P.43 32 point I/O unit Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks. 32 point output reduced common unit Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks.
Filter Series FN1/FN4 Blocking Characteristics (Repeatability) P Fluid: Potable water P Supply pressure: 0.2 MPa P Flow rate: 20 l/min P Test dust: AC course test dust P Test method: Per SMC test method Filter part no.: FN1101N-10-Sl, FN4102N-20-Sl Element: END100-020 (Cylindrical type, 20 m) 0.2 Pressure loss (MPa) 0.1 0.01 0 T1 T2 T3 T4 T5 100% 100% 100% 100% 100% 0 0 0 0 Time it takes