Note 2) When mounting a cylinder with a stroke over 100mm, use the section A mounting threads.
A-9 Comparison of a situation sketch with the simulation set-up and the ckcuil diagram P E U x A ' I c T E c H N o L o G Y S A M P L E D I A G B A M S We will look at this in a sample diagram. Diagram A-10 is the circuit tor the sequenc: "A+, B+, B-, A-". ll is divided into the thre levels, the power section on top, the signal inputrs on the bottom and in between the 'signal procssing'.
NEW Four AS3002F-10 controllers connected Controlled flow 112 27 27% DOWN CyL A Lift side Conventional Free flow Four AS3001F-10 controllers connected with holders (TMH-10) Index plate (example with identification label attached) Holder Lightweight Flow-rate characteristics are equivalent to the conventional product.
From Table 3.7: At 1soo, 10 m3 of air can hold a maximum of 13.04g/m..10m" = 130.4 g P N E U A T I c T E c H t t o L o G Y At 650/o r.h. the air will conlain 130.4 g '0.65 = 84.9 g {a) The reduced volume ol compressed air at 6 bar pressur can be calculated: pl'v1 = pzvz = p; v1 = v2 = +H# '10 m3 = 1.44 mc From Table 3.7 1.44m3of air at 25oC can hold a maximum of 23'76 g '1 '44 = 34.2 g (
Class22 A DC24 V 108 A () DC24 V +10/-5 Class22 A DC24 V +10/-58 A 1 IP67() -1050 -2060 3585%RH() AC500 V1 FE DC500 V10 M FE 3(UL508) CE UL(CSA)RoHS 170 g 175 g 1 EX600-ED2-31No.EX-OMN0029CN-D EX600-ED3-32No.EX-OMN0029CN-D (DC24 V10%) -33No.EX-OMN0029CN-D LED 0 1 LED Yes No SI 2 3 4 SI ST(M) 5 6 7 SI . -34No.EX-OMN0029CN-D SI 8 ST(M) ST(M) 9 / PWR PWR(V) 10
Example) For 10-CQSXB25-47D, a 3mm spacer is installed inside a standard stroke 10-CQSXB25-50D cylinder.
depth 7 2 x M5 x 0.8 M5 x 0.8 (Relief port) (Piping port) 5.5 2 x 3.5 through M6 x 1.0 38 0.5 20 29 8 Rod end nut 10 Flat washer 11.5 10 12 4 4 6 15.5 32 + Stroke 20 20 47.5 + Stroke 10 5 29 Lead wire minimum bending radius 10 Auto switch 18 5.5 2 x 2 x 9 counterbore 2 x 2 x M6 x 1.0 effective depth 10 5.5 2 x M5 x 0.8 M5 x 0.8 (Relief port) (Piping port) Note 2) M8 x 1.25 2 x 5.4 through
) 24.6 38 48 4 2 B A VS7 24.6 A B 38 48 14 12 5 3 1 A B 30 45 14 3 5 1 12 25.6 Mounting hole Manual override 25.6 Mounting hole 30 45 Manual override 14.5 27 30.5 32 41.5 91.5 129 79 PE X PE X 32 41.5 30.5 27 R1 R2 P R2 R1 14.5 P 19.5 19.5 (21) (21) Rc1/8 External pilot port Rc1/8 PE port 19.5 (21) 19.5 (21) 5-Rc (PT)1/4, 3/8 P, A, B, R1, R2 port 5-Rc (PT)1/4, 3/8 P, A, B, R1, R2 port Rc1
If an instantaneous flow of 10 L/min lasts for 5 minutes, the accumulated flow will be 10 x 5=50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.It is possible to calculate the total accumulated flow by counting the pulses.
Input/output 10 seconds for 4 cables. 10 seconds for 4 cables. Output Elimination of branch unit The function of a branch unit is built-in a 16 point unit, allowing reduction of the number of units.
Auto switch model Bore size [mm] 20 25 32 40 D-M9m(V) D-M9mW(V) BM8-020 (A set of a, b, c, d) BM8-025 (A set of a, b, c, d) BM8-032 (A set of a, b, c, d) BM8-040 (A set of a, b, c, d) BM8-025S (A set of a, b, c, d) * S: Stainless steel set screw BM8-032S (A set of a, b, c, d) * S: Stainless steel set screw BM8-040S (A set of a, b, c, d) * S: Stainless steel set screw D-M9mA(V) BM8-020S (A
Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL50-A, Type: Damper holding assembly
Case: [Resin] Resin, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL50-A, Type: Damper (assembly)
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
Using a regulator in the outlet side When mounting a regulator in the outlet side (A port side), use a residual pressure relief regulator (AR25K to 40K) or a check type regulator. With a standard regulator (AR10 to 60), the outlet side pressure may not be released when this valve is exhausted. 5.
force N Applicable cylinder bore size Model Nominal size Pitch Center of sphere R M A B D E F G H Weight kg 20 25 32 32, 40 40 32, 40 50 50, 63 44 49.5 49.5 60 60 60 71.5 71.5 17.5 19.5 19.5 20 20 20 22 22 21 24 24 31 31 31 41 41 4.5 5 5 6 6 6 7.5 7.5 7 8 8 11 11 11 14 14 7 8 8 11 11 11 13.5 13.5 13 17 17 22 22 22 27 27 30.5 34 34 38 38 38 44.5 44.5 8 9 9 13 13 13 15 15 0.5 0.5 0.5 0.75
12 14 EO 14 16 20 NB 5h9 6h9 6h9 DC 30 36 42 NA 8 10 12 DO 34 40 48 K 4 5 6 B 30 36 42 Q 6 7 8 J 10 12 14 AA 35 38 40 AB 32 35 37 O 2 2.5 3 P M3 x 0.5 M5 x 0.8 M5 x 0.8 0 -0.030 0 -0.030 0 -0.030 Model MHS2-16D MHS2-20D MHS2-25D VA 2H9 2H9 3H9 TB 5 6 6 SC 8 9.5 10 RB 16 18 22 RA 18 24 26 WA VB 2 2 3 XA 2H9 2H9 3H9 XB 2 2 3 +0.025 0 +0.025 0 +0.025 0 +0.043 0 +0.052 0 +0.052 0 +0.025 0 +0.025
90 89 -85No.PF-OMM0004-D PF3W711-U25/PF3W721-U30(PVC ) A B D E F J K L N P Q 25 A 154 46 77 57.6 23 77 63 28 18 3.5 14 32 30 A 146 56 91 71.6 28.5 73 60.5 25 27.5 3.5 14 38 S T U V W Y Z 25 A 59 36 48 58 70 7 2 -86No.PF-OMM0004-D M8 ZS-40-A -87No.PF-OMM0004-D EPDM 11 11 PVC -88No.PF-OMM0004-D Revision history A B C D SMC URL http://www.smcworld.com 2008-2013 SMC Corporation
controllers connected Controlled flow 112 27% DOWN 27% DOWN CyL A Lift side Current Free flow Four AS3001F-10 controllers connected with holders (TMH-10) Index plate (example with identification label attached) Holder Lightweight Flow rate characteristics are equivalent to the current product.
38 55 MXY8 2.5 CX 43 63 MXY12 2.5 D51 -X Lead wire entries parallel 2-color Display Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PV (mm) B A 20Model Mounting Switch operating range A B A B A B 50 MXY6 Data 38 55 4 MXY8 43 63 MXY12 51 Mounting of Auto Switch Caution Auto Switch Mounting Tool When tightening the auto switch set screw (included with auto switch), use a watchmakers screwdriver