SMC Corporation of America
Elite Part Number Search
Search Results "AMJ3000-F03B-2"

Body Size: 30, Back Flow: w/o Backflow, Thread: F (G), Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa

Body Size: 30, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 25, Backflow: K (w/Backflow Function), Thread: F (G), Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 40, Backflow: K (w/Backflow Function), Thread: F (G), Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: B (Bracket), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

Series AMJ is effective for removing water droplets from the air sucked into vacuum pumps and ejectors. Over 90% of droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, EA, AF MASS PRO 3/8 MODULAR (PT), .79141 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF301/4, 3/8Air?5 to 60C (with no freezing

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, EA, AL MASS PRO 3/8 MODULAR (PT), 0.85863 lb

SMCs?new AF modular style air filter combines the element and bowl in one piece, making element replacement easy.? There is a maximum 46% reduction in size, reducing required maintenance space.? The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.??The modular design of the AF allows connection with other SMC air preparation equipment. The series

Body Size: 40, Back Flow: w/o Backflow, Thread: F (G), Port Size: 03 (3/8), Mounting Option: B (With Bracket), Float Type Auto Drain Option: Without Auto Drain, Pressure Gauge/Switch Option: Without Pressure Gauge, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 8 (Metal Bowl w/Level Gauge), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow

Body Size: 30, Thread: G, Port Size: 3/8, Handle/Bonnet Material: Aluminum, Options: Built-in Silencer, EXH Port, Semi-Standard: Flow Direction: Right to Left, Made to Order: -

Body Size: 40, Thread: G, Port Size: 3/8, Handle/Bonnet Material: Aluminum, Options: w/Bracket + Built-in Silencer, EXH Port, Semi-Standard: Flow Direction: Right to Left, Made to Order: -

Body Size: 40, Thread: G, Port Size: 3/8, Handle/Bonnet Material: Aluminum, Options: Built-in Silencer, EXH Port, Semi-Standard: Flow Direction: Right to Left, Made to Order: -

Body Size: 40, Thread: G, Port Size: 3/8, Handle/Bonnet Material: Aluminum, Options: w/Bracket, Semi-Standard: Flow Direction: Right to Left, Made to Order: -

Body Size: 30, Thread: G, Port Size: 3/8, Handle/Bonnet Material: Aluminum, Options: w/Bracket + Built-in Silencer, EXH Port, Semi-Standard: Flow Direction: Right to Left, Made to Order: -